Flowing liquid sample jet for resonance Raman and ultrafast optical spectroscopy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A wire-guided, gravity-driven jet apparatus is described that produces optically stable thin films of liquids flowing at rates suitable for high repetition rate spectroscopy. Unlike conventional free-flowing jets, the design works well for low viscosity solvents including water and aqueous solutions of proteins. The construction of the wire guide, jet nozzle, and flow system is described. A stable water film whose thickness can be varied from 6 to 100 μm is demonstrated that has been employed in resonance Raman and femtosecond transient absorption experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The First Step in Vision: Femtosecond Isomerization of Rhodopsin
Schoenlein, R. W., Peteanu, L. A., Mathies, R. A., & Shank, C. V. (1991) · Science · doi:10.1126/science.1925597 · Cited by 892
Self-citation
Cited by
Femtosecond broadband stimulated Raman spectroscopy: Apparatus and methods
McCamant, D. W., Kukura, P., Yoon, S., & Mathies, R. A. (2004) · Review of Scientific Instruments · doi:10.1063/1.1807566 · Cited by 304
Self-citationMegerle, U., Pugliesi, I., Schriever, C., Sailer, C. F., & Riedle, E. (2009) · Applied Physics B · doi:10.1007/s00340-009-3610-0 · Cited by 273
Vibronic origin of long-lived coherence in an artificial molecular light harvester
Lim, J., Paleček, D., Caycedo-Soler, F., Lincoln, C. N., Prior, J., von Berlepsch, H., Huelga, S. F., Plenio, M. B., Zigmantas, D., & Hauer, J. (2015) · Nature Communications · doi:10.1038/ncomms8755 · Cited by 162
Observation of broadband terahertz wave generation from liquid water
Jin, Q., E, Y., Williams, K., Dai, J., & Zhang, X.-C. (2017) · Applied Physics Letters · doi:10.1063/1.4990824 · Cited by 161
A liquid flatjet system for solution phase soft-x-ray spectroscopy
Ekimova, M., Quevedo, W., Faubel, M., Wernet, P., & Nibbering, E. T. J. (2015) · Structural Dynamics · doi:10.1063/1.4928715 · Cited by 147
Metadata
- Authors
- Tauber, M. J., Mathies, R. A., Chen, X., & Bradforth, S. E.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2003-11-01
- Volume
- 74
- Issue
- 11
- Pages
- 4958-4960
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1987214958
- Cited by
- 137
- References
- 1
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flowing liquid sample jet for resonance Raman and ultrafast optical spectroscopy. https://app.cochat.ai/papers/10.1063/1.1614874
- The paper
- Tauber, M. J., Mathies, R. A., Chen, X., & Bradforth, S. E. (2003). Flowing liquid sample jet for resonance Raman and ultrafast optical spectroscopy. Review of Scientific Instruments. https://doi.org/10.1063/1.1614874
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.