CoChat

Miniature Ultrasensitive Superconducting Magnetic Gradiometer and Its Use in Cardiography and Other Applications

Zimmerman, J. E., Frederick, N. V. · 1971 · Applied Physics Letters

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

A portable magnetic gradiometer was built using an rf-biased point contact device as a sensor and a superconducting flux transformer 2.5 cm in diameter by 10 cm long to couple to the gradient of the external field. The instrument is limited by fluctuations which are probably associated with an uneven boiling of the cryogenic liquids and by environmental fluctuations in some locations. It is shown that the inherent sensitivity can be increased by an order of magnitude by increasing the bias frequency from 30 to 300 MHz. A possible use of the instrument as a magnetocardiograph in an unshielded environment was demonstrated.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.1653725

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 5 references

Cited by

Items 101–152 of 152

Metadata

Authors
Zimmerman, J. E., & Frederick, N. V.
Affiliations
National Institute of Standards and Technology (US)
Venue
Applied Physics Letters
Published
1971-07-01
Volume
19
Issue
1
Pages
16-19
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W1998344359
Cited by
152
References
5
Citations by year
2026: 2 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
FWCI
16.47
Type
journal article
Language
en
Open access
closed
Locations
Applied Physics Letters (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
Keywords
magnetocardiography, portable instrumentation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.