Miniature Ultrasensitive Superconducting Magnetic Gradiometer and Its Use in Cardiography and Other Applications
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A portable magnetic gradiometer was built using an rf-biased point contact device as a sensor and a superconducting flux transformer 2.5 cm in diameter by 10 cm long to couple to the gradient of the external field. The instrument is limited by fluctuations which are probably associated with an uneven boiling of the cryogenic liquids and by environmental fluctuations in some locations. It is shown that the inherent sensitivity can be increased by an order of magnitude by increasing the bias frequency from 30 to 300 MHz. A possible use of the instrument as a magnetocardiograph in an unshielded environment was demonstrated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the first technological alternative was the invention of superconducting pick-up coils designed as second- or higher-order gradiometers that would primarily measure the MF gradient closest to the source ignoring magnetic fields from further away (e.g., the environmental noise) (23).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [23]
Citations
Cites
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Self-citationQuantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Digital-Analog Magnetometer Utilizing Superconducting Sensor
Forgacs, R. L., & Warnick, A. (1967) · Review of Scientific Instruments · doi:10.1063/1.1771358 · Cited by 125
Recent Developments in Superconducting Devices
Zimmerman, J. E. (1971) · Journal of Applied Physics · doi:10.1063/1.1659587 · Cited by 49
Cited by
Items 101–152 of 152
Superconductivity: new roles for an old discovery
Duzer, T. V., & Turner, C. W. (1972) · IEEE Spectrum · doi:10.1109/mspec.1972.5218641 · Cited by 2
First-order SQUID gradiometer with electronic subtraction for magnetocardiography
Rau, M. C., & Octavian, B. (2012) · International Conference and Exposition on Electrical and Power Engineering (EPE) · doi:10.1109/icepe.2012.6463873 · Cited by 2
SQUID Gradiometer for Biomagnetic Fields
Baltag, O., & Rau, C. M. (2014) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-07653-9_28 · Cited by 1
Taulu, S., Simola, J., Nenonen, J., & Parkkonen, L. T. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_2-1 · Cited by 1
High-Tc superconductors toward small scale applications
Gerbaldo, R., Ghigo, G., Gozzelino, L., & Mezzetti, E. (2001) · Elsevier eBooks · doi:10.1016/b978-012513745-4/50027-5 · Cited by 1
Magnetic coupling enhancement using a flux transformer
Zhou, P., Quéval, L., & Ma, G. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aaf468 · Cited by 1
Williamson, S. J. (2003) · Wiley eBooks · doi:10.1002/3527600434.eap040 · Cited by 1
Tactile processing in human somatosensory and auditory cortices
Hlushchuk, Y. (2007) · Työväentutkimus Vuosikirja · Cited by 1
Giesler, T., Pohle, K., Flüg, M., Achenbach, S. S., Klinghammer, L., Moshage, W. E. L., & Daniel, W. G. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1998.43.s1.230 · Cited by 1
Direct-coupled high T/sub c/ DC SQUID gradiometer with single layer YBa/sub 2/Cu/sub 3/O/sub 7/
Huh, Y., Lee, S.-G., Kim, I.-S., Lee, Y. H., Kwon, H. C., Park, Y. K., Park, J.-C., Song, I., & Park, G. (1997) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.622034 · Cited by 1
Bruña, R. (2019) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.54514 · Cited by 3
Metrology for electromagnetic technology : a bibliography of NBS publications
Kamper, R. A. (1980) · doi:10.6028/nbs.ir.79-1625 · Cited by 1
Taylor, B. N. (1974) · Springer eBooks · doi:10.1007/978-1-4684-2691-5_80 · Cited by 1
Failure Analysis Tools, Models, and Physics of Failure
Voldman, S. H. (2009) · doi:10.1002/9780470747254.ch2
Factors affecting the performance of a SQUID gradiometer
Baltag, O., & Rau, M. C. (2015) · International Symposium on Advanced Topics in Electrical Engineering · doi:10.1109/atee.2015.7133945
High-Tc SQUIDs: Noise and applications
Lawrence Berkeley National Lab. (LBNL), B., Cho, H.-M., & USDOE (2001) · doi:10.2172/791794
Low noise, permanently adjusted UHF SQUID magnetometer
Clark, T. D., & Jackel, L. D. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058750
Influence of a superconducting quantum interferometer on magnetic gradient meter characteristics
Куликов, В. А., Popova, N. V., & Serebryakov, A. Y. (1990) · Measurement Techniques · doi:10.1007/bf00865195
Mutual influence of receiving loops in multichannel superconducting gradiometers
Куликов, В. А., Popova, N. V., & Serebryakov, A. Y. (1990) · Measurement Techniques · doi:10.1007/bf00976413
A method for studying the properties of a superconducting quantum detector of magnetic flux
Kozlov, V. A., Koslova, N. D., Savitskii, E. M., & Bykov, I. I. (1976) · Cryogenics · doi:10.1016/0011-2275(76)90269-1
Balancing of a superconductor gradienter
Куликов, В. А., Popova, N. V., & Serebryakov, A. Y. (1989) · Measurement Techniques · doi:10.1007/bf00863648
Longitudinal unbalance compensation in squid gradient meter probes
Куликов, В. А., Popova, N. V., & Serebryakov, A. Y. (1989) · Measurement Techniques · doi:10.1007/bf00866950
The fabrication and performance of YBa2Cu3O7-x SQUID magnetometers
Lawrence Berkeley National Lab. (LBNL), B., Kingston, J. J., USDOE, & Program, C. C. T. (1992) · doi:10.2172/10191738
A Review of Magnetoencephalography and Magnetic Evoked Fields
Hughes, J. R. (1988) · American Journal of EEG Technology · doi:10.1080/00029238.1988.11080273
Highly Sensitive and Selective Plasmonic Sensing Platforms
Saylan, Y., & Deni̇zli̇, A. (2021) · doi:10.1002/9783527830343.ch3
Voldman, S. H. (2013) · doi:10.1002/9781118703328.ch04
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2011) · Springer eBooks · doi:10.1007/978-0-85729-880-5_12
Metrology for electromagnetic technology : a bibliography of NBS publications
Kline, K. E., & DeWeese, M. E. (1986) · doi:10.6028/nbs.ir.86-3048
Metrology for electromagnetic technology : a bibliography of NBS publications
Kline, K. E., & DeWeese, M. E. (1987) · doi:10.6028/nbs.ir.87-3074
Metrology for electromagnetic technology : a bibliography of NIST publications
DeWeese, M. E., & Meynihan, S. (1992) · doi:10.6028/nist.ir.3994
Voldman, S. H. (2021) · doi:10.1002/9781119233091.ch7
Metrology for electromagnetic technology : a bibliography of NBS publications
Kamper, R. A., & Kline, K. E. (1984) · doi:10.6028/nbs.ir.84-3014
SQUID Magnetometric System and SQUID Parameters
Zhang, Y., Dong, H., Krause, H., Zhang, G., & Xie, X. (2020) · Wiley eBooks · doi:10.1002/9783527816514.ch6
metrology for electromagnetic technology : a bibliography of NBS publications
Kline, K. E., & DeWeese, M. E. (1985) · doi:10.6028/nbs.ir.85-3029
DESENVOLVIMENTO E CARACTERIZAÇÃO DE GRADIÔMETRO GMI DE ALTA SENSIBILIDADE
Riveros, P. A. D. (2017) · doi:10.17771/pucrio.acad.32032 · Cited by 1
Metrology for electromagnetic technology : a bibliography of NBS publications
Kamper, R. A., & Kline, K. E. (1982) · doi:10.6028/nbs.ir.82-1677
Simulation and Parameter Optimization of Two-Dimensional SQUID Gradiometer
Wu, W., Zhang, Z., Li, S., Xu, Z., & Kong, X. (2024) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2024.3420332
“Asaresult,thegradiometerbasedonthespatial differencecansuppressthecommonmodenoiseandimprove thesignal-to-noiseratio(SNR)[9].”
Bostock, J. (1973) · Springer eBooks · doi:10.1007/978-1-4615-8978-5_14
Persistent-current-biased and current-actuated switch for superconducting circuits
Anonymous, Gurra, E., Vissers, M. R., & Lehnert, K. W. (2026) · Physical Review Applied · doi:10.1103/9r4s-6zj2
Intelligent Quality Assessment of Magnetocardiography Time-Series Signals Based on Deep Learning
Tong, J., Chu, C., & Li, B. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-37739-5_30
Carrico, J. P., & Stein, T. S. (1973) · Applied Scientific Research · doi:10.1007/bf00413067
Metadata
- Authors
- Zimmerman, J. E., & Frederick, N. V.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1971-07-01
- Volume
- 19
- Issue
- 1
- Pages
- 16-19
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1998344359
- Cited by
- 152
- References
- 5
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
- FWCI
- 16.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, portable instrumentation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.