Miniature Ultrasensitive Superconducting Magnetic Gradiometer and Its Use in Cardiography and Other Applications
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A portable magnetic gradiometer was built using an rf-biased point contact device as a sensor and a superconducting flux transformer 2.5 cm in diameter by 10 cm long to couple to the gradient of the external field. The instrument is limited by fluctuations which are probably associated with an uneven boiling of the cryogenic liquids and by environmental fluctuations in some locations. It is shown that the inherent sensitivity can be increased by an order of magnitude by increasing the bias frequency from 30 to 300 MHz. A possible use of the instrument as a magnetocardiograph in an unshielded environment was demonstrated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the first technological alternative was the invention of superconducting pick-up coils designed as second- or higher-order gradiometers that would primarily measure the MF gradient closest to the source ignoring magnetic fields from further away (e.g., the environmental noise) (23).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [23]
Citations
Cites
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Self-citationQuantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Digital-Analog Magnetometer Utilizing Superconducting Sensor
Forgacs, R. L., & Warnick, A. (1967) · Review of Scientific Instruments · doi:10.1063/1.1771358 · Cited by 125
Recent Developments in Superconducting Devices
Zimmerman, J. E. (1971) · Journal of Applied Physics · doi:10.1063/1.1659587 · Cited by 49
Cited by
High-transition-temperature superconducting quantum interference devices
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.631 · Cited by 396
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Advanced superconducting gradiometer/Magnetometer arrays and a novel signal processing technique
Wynn, W., Frahm, C., Carroll, P., Clark, R., Wellhoner, J., & Wynn, M. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058672 · Cited by 205
Magnetomyography: magnetic fields around the human body produced by skeletal muscles
Cohen, D., & Givler, E. (1972) · Applied Physics Letters · doi:10.1063/1.1654294 · Cited by 109
Measurements of the magnetic fields produced by the human heart, brain, and lungs
Cohen, D. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058698 · Cited by 108
Koch, R. H., Rozen, J. R., Sun, J., & Gallagher, W. J. (1993) · Applied Physics Letters · doi:10.1063/1.110032 · Cited by 89
McDonald, D. G., Risley, A. S., Cupp, J. D., Evenson, K. M., & Ashley, J. R. (1972) · Applied Physics Letters · doi:10.1063/1.1654156 · Cited by 89
Superconducting thin-film gradiometer
Ketchen, M. B., Goubau, W. M., Clarke, J., & Donaldson, G. B. (1978) · Journal of Applied Physics · doi:10.1063/1.325373 · Cited by 87
Low-frequency applications of superconducting quantum interference devices
Clarke, J. L. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.8964 · Cited by 85
Thin-film multilayer interconnect technology for YBa2Cu3O7−x
Wellstood, F. C., Kingston, J. J., & Clarke, J. L. (1994) · Journal of Applied Physics · doi:10.1063/1.356469 · Cited by 78
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
The human magnetoencephalogram: some EEG and related correlations
Reite, M. L., Zimmerman, J. E., EDRICH, J., & Zimmerman, J. T. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90179-6 · Cited by 82
Josephson effect devices and low-frequency field sensing
Zimmerman, J. E. (1972) · Cryogenics · doi:10.1016/0011-2275(72)90133-6 · Cited by 78
Prance, R. J., Long, A. P., Clark, T. D., Widom, A., Mutton, J. E., Sacco, J. E., Potts, M., Megaloudis, G., & Goodall, F. N. (1981) · Nature · doi:10.1038/289543a0 · Cited by 65
Usefulness of magnetocardiography for the investigation of fetal arrhythmias
Menéndez, T., Achenbach, S. S., Beinder, E., Hofbeck, M., Klinghammer, L., Singer, H., Moshage, W. E. L., & Daniel, W. G. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01658-7 · Cited by 65
Broadband Superconducting Quantum Magnetometer
Kamper, R. A., & Simmonds, M. B. (1972) · Applied Physics Letters · doi:10.1063/1.1654144 · Cited by 62
Flux noise from superconducting YBa2Cu3O7−x flux transformers
Ferrari, M. J., Kingston, J. J., Wellstood, F. C., & Clarke, J. L. (1991) · Applied Physics Letters · doi:10.1063/1.104386 · Cited by 60
Biomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 66
“gradiometer design for the superconducting pickup coil (Figure 2), SQUID magnetometers could record the MCG without the need for a shielded room [11].”
BackgroundSuperconducting Quantum Interference Devices for Low Frequency Measurements
Clarke, J. L. (1977) · Springer eBooks · doi:10.1007/978-1-4684-2805-6_3 · Cited by 64
Theories, Applications, and Expectations for Magnetic Anomaly Detection Technology: A Review
Liu, H., Zhang, X., Dong, H., Liu, Z., & Hu, X. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3294498 · Cited by 52
“in the human medical monitoring [15], [158], [159].”
BackgroundGallop, J. C., & Petley, B. W. (1976) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/9/6/001 · Cited by 54
Superconducting thin-film multiturn coils of YBa2Cu3O7−x
Wellstood, F. C., Kingston, J. J., & Clarke, J. L. (1990) · Applied Physics Letters · doi:10.1063/1.103247 · Cited by 48
Magnetic fields of the human body
Cohen, D. (1975) · Physics Today · doi:10.1063/1.3069110 · Cited by 48
Moshage, W. E. L., Achenbach, S. S., Göhl, K., & Bachmann, K. F. (1996) · International journal of cardiac imaging · doi:10.1007/bf01798116 · Cited by 51
Superconducting instrument systems
Goodman, W. L., Hesterman, V. W., Rorden, L. H., & Goree, J. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.8965 · Cited by 51
Superconducting thin-film flux transformers of YBa2Cu3O7−x
Wellstood, F. C., Kingston, J. J., Ferrari, M. J., & Clarke, J. L. (1990) · Applied Physics Letters · doi:10.1063/1.104015 · Cited by 42
Hoenig, H. E., Daalmans, G., Folberth, W., Reichenberger, H., Schneider, S., & Seifert, H. (1989) · Cryogenics · doi:10.1016/0011-2275(89)90154-9 · Cited by 42
Spietz, L., Irwin, K. D., & Aumentado, J. (2008) · Applied Physics Letters · doi:10.1063/1.2970967 · Cited by 37
A second derivative gradiometer integrated with a dc superconducting interferometer
Carelli, P., & Foglietti, V. (1983) · Journal of Applied Physics · doi:10.1063/1.331757 · Cited by 37
Application of SQUID sensors to the investigation of neural activity in the human brain
Williamson, S. J., & Kaufman, L. (1983) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1983.1062555 · Cited by 38
Boston and the history of biomagnetism.
Cohen, D. (2004) · PubMed · Cited by 43
Spietz, L., Irwin, K. D., & Aumentado, J. (2009) · Applied Physics Letters · doi:10.1063/1.3220061 · Cited by 30
Unidirectional magnetic gradiometers
Karp, P., & Duret, D. (1980) · Journal of Applied Physics · doi:10.1063/1.327819 · Cited by 30
Clarke, J. L. (1974) · Science · doi:10.1126/science.184.4143.1235 · Cited by 40
Experiments on magnetization in superfluid3He
Webb, R. A., Sager, R. E., & Wheatley, J. C. (1977) · Journal of Low Temperature Physics · doi:10.1007/bf00655421 · Cited by 29
Time-Division SQUID Multiplexers With Reduced Sensitivity to External Magnetic Fields
Stiehl, G. M., Cho, H.-M., Hilton, G. C., Irwin, K. D., Mates, J. A. B., Reintsema, C. D., & Zink, B. L. (2010) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2010.2091483 · Cited by 28
“Since the development of gradiometric SQUIDs at NIST in 1971 [12], it has become common practice to use gradiometry in order to reduce a SQUID amplifier’s coupling to the external environment.”
MethodAir-core induction-coil magnetometer design
Estola, K. P., & Malmivuo, J. A. (1982) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/15/10/034 · Cited by 27
High-performance UHF SQUID magnetometer
Long, A. P., Clark, T. D., Prance, R. J., & Richards, M. G. (1979) · Review of Scientific Instruments · doi:10.1063/1.1135717 · Cited by 26
Xi, H., Qian, X., Lu, M.-C., Mei, L., Rupprecht, S., Yang, Q., & Zhang, Q. (2016) · Scientific Reports · doi:10.1038/srep29740 · Cited by 27
Taulu, S., Simola, J., Nenonen, J., & Parkkonen, L. T. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_2 · Cited by 31
Solutions of the Schrödinger equation for a superconducting weak link constriction ring
Mutton, J. E., Prance, R. J., & Clark, T. D. (1984) · Physics Letters A · doi:10.1016/0375-9601(84)90820-x · Cited by 24
The response of a superconducting weak-link ring to external adiabatic noise
Prance, R. J., Spiller, T. P., Prance, H., Clark, T. D., Ralph, J. F., Clippingdale, A. J., Srivastava, Y. N., & Widom, A. (1991) · Il Nuovo cimento della Società italiana di fisica. B/Il Nuovo cimento B · doi:10.1007/bf02725694 · Cited by 23
Application of superconducting magnetometers to the measurement of the vector magnetocardiogram
Wikswo, J., & Fairbank, W. (1977) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1977.1059333 · Cited by 22
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Portable helium dewars for use with superconducting magnetometers
Zimmerman, J. E., & Siegwarth, J. D. (1973) · Cryogenics · doi:10.1016/0011-2275(73)90284-1 · Cited by 22
Varactor tuned ultrahigh frequency SQUID magnetometer
Long, A. P., Clark, T. D., & Prance, R. J. (1980) · Review of Scientific Instruments · doi:10.1063/1.1136026 · Cited by 21
Silver, A. H., & Zimmerman, J. E. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-517701-6.50007-0 · Cited by 22
SQUID techniques.I. Obtaining reliability in point-contact SQUID's
Buhrman, R. A., Lukens, J. E., Jackel, L. D., Strait, S. F., Warlaumont, J. M., & Webb, W. W. (1974) · Journal of Applied Physics · doi:10.1063/1.1663910 · Cited by 21
Ikefuji, H., Nomura, M., Nakaya, Y., Mori, T., Kondo, N., 家石, 潔., Fujimoto, S., & Ito, S. (2007) · The Journal of Medical Investigation · doi:10.2152/jmi.54.116 · Cited by 21
“(1) Ventricular depolarization vectors in patients”
MethodInfluentialOperating characteristics of thin-film rf-biased SQUID’s
Falco, C. M., & Parker, W. H. (1975) · Journal of Applied Physics · doi:10.1063/1.322049 · Cited by 20
A Study of the Vector Magnetocardiographic Waveform
Rosen, A., & Inouye, G. T. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324556 · Cited by 20
Forty Years of Magnetocardiology
Stroink, G. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_1 · Cited by 21
Discrete spatial filtering with SQUID gradiometers in biomagnetism
Bruno, A. C., Ribeiro, P. C., von der Weid, J. P., & Symko, O. G. (1986) · Journal of Applied Physics · doi:10.1063/1.337008 · Cited by 20
Malhotra, A., von Gladiss, A., Behrends, A., Friedrich, T., Neumann, A., Buzug, T. M., & Lüdtke‐Buzug, K. (2019) · Scientific Reports · doi:10.1038/s41598-019-46882-6 · Cited by 28
Biomagnetism: An application of squid sensors to medicine and physiology
Romani, G. L. (1984) · Physica B+C · doi:10.1016/0378-4363(84)90147-5 · Cited by 23
Simple, low-noise uhf SQUID magnetometer
Clark, T. D., & Jackel, L. D. (1975) · Review of Scientific Instruments · doi:10.1063/1.1134455 · Cited by 17
Seki, Y., & Kandori, A. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.3397 · Cited by 16
Extracorporeal magnetic fields generated by internal bioelectric sources
Geselowitz, D. A., & Miller, W. (1973) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1973.1067660 · Cited by 20
Recent developments in the measurement of magnetic fields from isolated nerves and muscles (invited)
Wikswo, J. P. (1981) · Journal of Applied Physics · doi:10.1063/1.328998 · Cited by 17
High Tc superconducting asymmetric gradiometer for biomagnetic applications
Kouznetsov, K., Borgmann, J., & Clarke, J. L. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150706 · Cited by 16
What Does Ultrasensitive Really Mean?
Gooding, J. J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00404 · Cited by 16
Digital filter design approach for SQUID gradiometers
Bruno, A. C., & Ribeiro, P. C. (1988) · Journal of Applied Physics · doi:10.1063/1.340983 · Cited by 14
Spatial Fourier transform method for evaluating SQUID gradiometers
Ribeiro, P. C., Bruno, A. C., Paulsen, C., & Symko, O. G. (1987) · Review of Scientific Instruments · doi:10.1063/1.1139390 · Cited by 14
Linearity of high-T c dc superconducting quantum interference device operated in a flux-locked loop
Nichols, D. G., Dantsker, E., Kleiner, R., Mück, M., & Clarke, J. L. (1996) · Journal of Applied Physics · doi:10.1063/1.363603 · Cited by 12
Neuroelectromagnetic Source Imaging of Brain Dynamics
Ramírez, R. R., Wipf, D., & Baillet, S. (2010) · Springer optimization and its applications · doi:10.1007/978-0-387-88630-5_8 · Cited by 17
“Not long after, the superconducting quantum interference device (SQUID) was invented [103].”
BackgroundThin-film flux transformers of YBa/sub 2/Cu/sub 3/O/sub 7-x/
Wellstood, F. C., Kingston, J. J., Ferrari, M. J., & Clarke, J. L. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133740 · Cited by 11
Spatial Fourier calibration method for multichannel SQUID magnetometers
Bruno, A. C., & Ribeiro, P. C. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142049 · Cited by 11
Williamson, S. J., Kaufman, L., & Brenner, D. A. (1977) · Springer eBooks · doi:10.1007/978-1-4684-2805-6_8 · Cited by 10
Flux transformers made of commercial high critical temperature superconducting wires
Dyvorne, H., Scola, J., Fermon, C., Jacquinot, J. F., & Pannetier-Lecoeur, M. (2008) · Review of Scientific Instruments · doi:10.1063/1.2885610 · Cited by 10
A symmetric third order gradiometer without external balancing or magnetocardiography
Bruno, A. C., & Ribeiro, P. C. (1983) · Cryogenics · doi:10.1016/0011-2275(83)90163-7 · Cited by 10
Rachford, F. J., Huang, C. Y., Wolf, S. A., & Nisenoff, M. (1974) · Applied Physics Letters · doi:10.1063/1.1655130 · Cited by 10
Thin-film DC SQUID gradiometer
Ketchen, M. B., Goubau, W. M., Clarke, J. L., & Donaldson, G. B. (1977) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1977.1059485 · Cited by 10
Distribution of m.e.g. detector sensitivity: an application of reciprocity
Malmivuo, J. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443394 · Cited by 9
Analysis and operation of UHF SQUID with tapped tank circuit
Jackel, L. D., Stoeckenius, J. H. W., & Epworth, R. W. (1978) · Journal of Applied Physics · doi:10.1063/1.324366 · Cited by 9
Taulu, S., Simola, J., Nenonen, J., & Parkkonen, L. T. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_2 · Cited by 10
Low-frequency noise spectra of a superconducting magnetic gradiometer
Gillespie, G. H., Podney, W. N., & Buxton, J. L. (1977) · Journal of Applied Physics · doi:10.1063/1.323334 · Cited by 8
On some aspects of superconducting quantum interferometer optimization
Vasiliev, B. V., Danilov, V. I., & Likharev, K. K. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058688 · Cited by 8
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3_44 · Cited by 9
High-T/sub c/ thin-film magnetometer
Miklich, A. H., Wellstood, F. C., Kingston, J. J., Clarke, J. L., Colclough, M. S., Cardona, A. H., Bourne, L. C., Olson, W. L., & Eddy, M. M. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133896 · Cited by 7
Rosen, A., Inouye, G. T., Morse, A., & Judge, D. L. (1972) · Journal of Applied Physics · doi:10.1063/1.1661415 · Cited by 7
Helical Resonator for VHF SQUID Operation
Corruccini, L. R. (1973) · Review of Scientific Instruments · doi:10.1063/1.1686365 · Cited by 7
Review of superconducting electronics
Kamper, R. A. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058655 · Cited by 7
Fully engineered high performance UHF SQUID magnetometer
Prance, R. J., Clark, T. D., Long, A. P., & Moore, M. (1981) · Cryogenics · doi:10.1016/0011-2275(81)90072-2 · Cited by 6
Kautz, R. L. (2001) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.919524 · Cited by 6
A SQUID gradiometer module with large junction shunt resistors
Qiu, Y., Liu, C., Zhang, S., Zhang, G., Wang, Y., Li, H., Zeng, J., Kong, X., & Xie, X. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/8/088503 · Cited by 5
Sun, C., Liang, Y., Yang, X., Zhao, B., Zhang, P., Liu, S., Yang, D., Wu, T., Zhang, J., & Guo, H. (2024) · iScience · doi:10.1016/j.isci.2024.110167 · Cited by 5
Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands
Campbell, K., Wang, Y.-J., Savukov, I., Schwindt, P. D. D., Jau, Y., & Shah, V. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.163602 · Cited by 4
Velázquez, D. R. T., Monteiro, E. C., Louzada, D. R., & Barbosa, C. R. H. (2020) · International Journal of Metrology and Quality Engineering · doi:10.1051/ijmqe/2020013 · Cited by 4
Spatial deconvolution algorithm for superconducting planar gradiometer arrays
Bruno, A. C., & Ribeiro, P. C. (1989) · IEEE Transactions on Magnetics · doi:10.1109/20.92515 · Cited by 4
Using the semiconductor junction in quantum interference devices
Simmonds, M. B. (1974) · Journal of Applied Physics · doi:10.1063/1.1662986 · Cited by 4
Experimental localization ability of planar gradiometer systems for biomagnetic measurements
Bruno, A. C., Pizzella, V., Torrioli, G., & Romani, G. L. (1989) · IEEE Transactions on Magnetics · doi:10.1109/20.92498 · Cited by 4
Developments in Cryoelectronics
Kamper, R. A. (1972) · doi:10.6028/nbs.tn.630 · Cited by 4
Application of flat dc-thin film SQUID's and technique for biomagnetic measurements
Albrecht, G. T., Hiibert, A., Kirsch, G., Nowak, H., Vodel, W., & Zach, H. G. (1981) · Cryogenics · doi:10.1016/0011-2275(81)90231-9 · Cited by 3
Optimization of a squid vector gradiometer
Lekkala, J. O., & Malmivuo, J. A. (1985) · Cryogenics · doi:10.1016/0011-2275(85)90012-8 · Cited by 3
King, C. A. (1971) · Review of Scientific Instruments · doi:10.1063/1.1684981 · Cited by 3
New type of second-order high-Tc SQUID planar gradiometer
Lang, P., Zheng, D., Zhang, M. J., Chen, K., Qi, H. H., & Zhao, Z. (2004) · Physica C Superconductivity · doi:10.1016/j.physc.2004.05.017 · Cited by 3
Observation of sine modulated bessel behavior in microwave biased SQUIDs
Rachford, F. J., Huang, C., Nisenoff, M., & Wolf, S. A. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058754 · Cited by 3
Low- and High-Tc Squids and Some Applications
Clarke, J. L. (2000) · Springer eBooks · doi:10.1007/978-94-017-0752-7_1 · Cited by 2
Superconductive Switches and Amplifiers
Goree, W. S., & Hesterman, V. W. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-517701-6.50008-2 · Cited by 2
Metadata
- Authors
- Zimmerman, J. E., & Frederick, N. V.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1971-07-01
- Volume
- 19
- Issue
- 1
- Pages
- 16-19
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1998344359
- Cited by
- 152
- References
- 5
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
- FWCI
- 16.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, portable instrumentation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.