The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Optical Fluorescence System for Quantitative Pressure Measurement in the Diamond-Anvil Cell
Abstract
An optical system for rapid routine pressure measurement is described which utilizes a pressure shift in the sharp R-line fluorescence spectrum of ruby or similar materials. The system, which consists of a standard polarizing microscope and a 1/4 m monochromator with associated photodetection system, is used with the diamond-anvil pressure cell, but can be employed with suitable modification in any pressure system which has optical access. The precision of the pressure measurement in a hydrostatic environment up to 100 kilobar is 0.5 kilobar using ruby as the pressure sensor. This precision is better than the accuracy of the present pressure scale above 40 kilobar. The merits of fluorescent materials other than ruby as pressure sensors are also discussed. A description of a Waspaloy diamond cell with some modifications in design is given. This improved cell and associated techniques extends the pressure range in gasketed systems up to 200 kilobar at room temperature and to moderate pressures at 700° C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern very high pressure techniques
Wentorf, R. H. (1962) · University Microfilms International eBooks · Cited by 221
Cited by
Calibration of the pressure dependence of the R 1 ruby fluorescence line to 195 kbar
Piermarini, G. J., Block, S., Barnett, J. D., & Forman, R. A. (1975) · Journal of Applied Physics · doi:10.1063/1.321957 · Cited by 2,038
Self-citationSupercooled dynamics of glass-forming liquids and polymers under hydrostatic pressure
Roland, C. M., Hensel-Bielowka, S., Paluch, M., & Casalini, R. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/6/r03 · Cited by 702
Measurement of the Raman spectrum of liquid water
Carey, D. M., & Korenowski, G. M. (1998) · The Journal of Chemical Physics · doi:10.1063/1.475659 · Cited by 645
Size Dependence of Structural Metastability in Semiconductor Nanocrystals
Chen, C.-C., Herhold, A. B., Johnson, C. S., & Alivisatos, A. P. (1997) · Science · doi:10.1126/science.276.5311.398 · Cited by 570
Tolbert, S. H., & Alivisatos, A. P. (1994) · Science · doi:10.1126/science.265.5170.373 · Cited by 563
Metadata
- Authors
- Barnett, J. D., Block, S., & Piermarini, G. J.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1973-01-01
- Volume
- 44
- Issue
- 1
- Pages
- 1-9
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2101585065
- Cited by
- 1,041
- References
- 1
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.