Currents to Conductors Induced by a Moving Point Charge
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
General expressions are derived for the currents which flow in the external circuit connecting a system of conductors when a point charge is moving among the conductors. The results are applied to obtain explicit expressions for several cases of practical interest.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Any form of particle detection and cooling with resonant circuits is based on the fact that the motion of charged particles in a Penning trap induces image currents in the conducting electrodes of the trap (Shockley-Ramo theorem [11,12]).”
From Off-resonance electronic detection and cooling of ions in a Penning trap (2024) · cites this paper as [11]
Citations
Cites
Fundamentals of engineering electronics
Dow, W. G. (1953) · Journal of the Franklin Institute · doi:10.1016/0016-0032(53)90758-3 · Cited by 43
Cited by
Items 201–300 of 1,000
Single-Ion Mass Spectrometry for Heterogeneous and High Molecular Weight Samples
Jarrold, M. F. (2024) · Journal of the American Chemical Society · doi:10.1021/jacs.3c08139 · Cited by 34
Shen, N., He, X., Gao, T., Xiao, B., Wang, Y., Ren, R., Qin, H., Bayikadi, K. S., Liu, Z., Peters, J. A., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-63400-7 · Cited by 34
“As de fi ned by the Shockley-Ramo theorem 46,47 , the transient induced charge Q is given by Q = − q φ ( x ), where φ ( x ) is the weighting potential as a function of position x inside the detector.”
10B4C Multi-Grid as an Alternative to 3He for Large Area Neutron Detectors
Correa, J. (2013) · Universidad de Zaragoza eBooks · doi:10.26754/uz.978-84-15770-39-8 · Cited by 35
Temporal response of CZT detectors under intense irradiation
Du, Y., LeBlanc, J. W., Possin, G. E., Yanoff, B. D., & Bogdanovich, S. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.815348 · Cited by 37
Ambiguities in the grid-inefficiency correction for Frisch-Grid Ionization Chambers
Al-Adili, A., Hambsch, F.-J., Bencardino, R., Oberstedt, S., & Pomp, S. (2011) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2011.01.088 · Cited by 37
Overview of GaAs und CdTe Pixel Detectors Using Medipix Electronics
Fiederle, M., Procz, S., Hamann, E., Fauler, A., & Fröjdh, C. (2020) · Crystal Research and Technology · doi:10.1002/crat.202000021 · Cited by 35
Abbene, L., Gerardi, G., Principato, F., Buttacavoli, A., Altieri, S., Protti, N., Tomarchio, E. A., Sordo, S. D., Auricchio, N., Bettelli, M., et al. (2020) · Journal of Synchrotron Radiation · doi:10.1107/s1600577520010747 · Cited by 34
“Generally, the generation of pulses in CZT detectors can be clearly explained through the Shockley–Ramo theorem (He et al., 2001; Knoll, 2000; Ramo, 1939; Shockley, 1938) with the concept of weighting potential.”
Simulation of semiconductor detectors in 3D with SolidStateDetectors.jl
Abt, I., Fischer, F., Hagemann, F., Hauertmann, L., Schulz, O., Schuster, M., & Zsigmond, A. J. (2021) · Journal of Instrumentation · doi:10.1088/1748-0221/16/08/p08007 · Cited by 39
Sub-10 ps Minimum Ionizing Particle Detection With Geiger-Mode APDs
Gramuglia, F., Ripiccini, E., Fenoglio, C. A., Wu, M.-L., PAOLOZZI, L., Bruschini, C. E., & Charbon, E. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.849237 · Cited by 38
“According to the Schockley-Ramo theorem [1, 2], this current is proportional to the free charge Q, to the speed of the charge carriers v, and to the weighting field, which can be expressed, to a first approximation, as 1 d , where d is the thickness of the depletion region.”
Method3D reconstruction of particle tracks in a 2 mm thick CdTe hybrid pixel detector
Bergmann, B. L., Burian, P., Mánek, P., & Pospíšil, S. (2019) · The European Physical Journal C · doi:10.1140/epjc/s10052-019-6673-z · Cited by 36
Cluster experiments in radio frequency Paul traps: Collisional relaxation and dissociation
Parks, J. H., Pollack, S., & Hill, W. (1994) · The Journal of Chemical Physics · doi:10.1063/1.468361 · Cited by 35
Optimization criteria for coplanar-grid detectors
Amman, M. S., & Luke, P. N. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775515 · Cited by 35
Extension of the Pierce Model to Multiple Transmission Lines Interacting With an Electron Beam
Tamma, V. A., & Capolino, F. (2014) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2014.2308575 · Cited by 35
“Formulation of MTL With Current Generators In the Pierce model, the beam with current I0 + Ib was assumed to pass very close to the circuit, therefore inducing a current in the TL over the incremental distance z [25], [26] and reflected in the TL equations as an equivalent parallel current generator per unit length, w…”
MethodPavlica, E., & Bratina, G. (2012) · Applied Physics Letters · doi:10.1063/1.4742149 · Cited by 32
A Deterministic Approach to RF Noise in Silicon Devices Based on the Langevin Boltzmann Equation
Jungemann, C. (2007) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2007.893210 · Cited by 34
“For example, in the case of the current of the kth terminal, it is given with the Ramo–Shockley theorem by (stationary conditions) [26]–[29]”
MethodElectron transport in a quantum wire with realistic Coulomb interaction
Sablikov, V. A., & Shchamkhalova, B. S. (1998) · Physical review. B, Condensed matter · doi:10.1103/physrevb.58.13847 · Cited by 32
Linear excitation and detection in Fourier transform ion cyclotron resonance mass spectrometry
Grosshans, P. B., Chen, R., Limbach, P. A., & Marshall, A. G. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)90034-5 · Cited by 32
Frensley, W. R. (1988) · Superlattices and Microstructures · doi:10.1016/0749-6036(88)90225-x · Cited by 32
Abbene, L., Principato, F., Gerardi, G., Bettelli, M., Seller, P., Veale, M. C., Zambelli, N., Benassi, G., & Zappettini, A. (2017) · Journal of Synchrotron Radiation · doi:10.1107/s1600577517015697 · Cited by 32
Single- Versus Multi-Step Trap Assisted Tunneling Currents—Part I: Theory
Schleich, C., Waldhoer, D., Knobloch, T., Zhou, W., Stampfer, B., Michl, J., Waltl, M., & Grasser, T. (2022) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2022.3185966 · Cited by 34
Hard x-ray response of pixellated CdZnTe detectors
Abbene, L., Sordo, S. D., Caroli, E., Gerardi, G., Raso, G., Caccia, S., & Bertuccio, G. (2009) · Journal of Applied Physics · doi:10.1063/1.3153161 · Cited by 31
Marinelli, M., Milani, E., Paoletti, A. M., Tucciarone, A., Verona-Rinati, G., Angelone, M., & Pillon, M. (2001) · Journal of Applied Physics · doi:10.1063/1.1332805 · Cited by 35
Pulse shape discrimination performance of inverted coaxial Ge detectors
Domula, A. R., Hult, M., Kermaïdic, Y., Marissens, G., Schwingenheuer, B., Wester, T., & Zuber, K. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.02.056 · Cited by 30
Operation of resonant-tunneling diodes beyond resonant-state-lifetime limit
Feiginov, M., & Chowdhury, D. R. (2007) · Applied Physics Letters · doi:10.1063/1.2806922 · Cited by 32
Noise spectra of ac-driven quantum dots: Floquet master-equation approach
Wu, B. H., & Timm, C. (2010) · Physical Review B · doi:10.1103/physrevb.81.075309 · Cited by 30
Zanichelli, M., Santi, A., Pavesi, M., & Zappettini, A. (2013) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/46/36/365103 · Cited by 35
“Regarding the weighting field w( r), it is defined [17, 18] as a vectorial weight function expressed in m−1; for a planar detector this field is constant and equal to 1/L (where L is the detector thickness) and it is directed along the detector axis (i.”
BackgroundKabir, M. Z., Emelianova, E. V., Arkhipov, V. I., Yunus, M., Kasap, S. O., & Adriaenssens, G. J. (2006) · Journal of Applied Physics · doi:10.1063/1.2206096 · Cited by 30
Detection of small bunches of ions using image charges
Räcke, P., Spemann, D., Gerlach, J. W., Rauschenbach, B., & Meijer, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-28167-6 · Cited by 31
Measurement of mobility and lifetime of electrons and holes in a Schottky CdTe diode
Ariño‐Estrada, G., Chmeissani, M., de Lorenzo, G., Kolstein, M., Puigdengoles, C., Garcia, J. G., & Cabruja, E. (2014) · Journal of Instrumentation · doi:10.1088/1748-0221/9/12/c12032 · Cited by 31
“Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.doi:10.1088/1748-0221/9/12/ C12032 1Corresponding author., garino@ifae.es. uthor M anuscripts E urope PM C Funders A uthor M anuscripts increases the time walk and hence the timing resol…”
InfluentialShiktorov, P., Starikov, E., Gružinskis, V., Varani, L., Sabatini, G., Marinchio, H., & Reggiani, L. (2009) · Journal of Statistical Mechanics Theory and Experiment · doi:10.1088/1742-5468/2009/01/p01047 · Cited by 31
Semiconductor characterization by scanning ion beam induced charge (IBIC) microscopy
Vittone, E., Pastuović, Ž., Olivero, P., Manfredotti, C., Jakšić, M., Giudice, A. L., Fizzotti, F., & Colombo, E. (2008) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2007.12.083 · Cited by 32
Particle Detectors: Fundamentals and Applications
Kolanoski, H., & Wermes, N. (2020) · doi:10.1093/oso/9780198858362.001.0001 · Cited by 81
El‐Nabulsi, R. A. (2021) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2021.114845 · Cited by 32
A study of fast neutron interactions in high-purity germanium detectors
Ljungvall, J., & Nyberg, J. (2005) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2005.03.122 · Cited by 35
Sensitivity of stabilized a-Se based X-ray photoconductors
Kabir, M. Z., Yunus, M., Kasap, S. O., Tousignant, O., Mani, H., & Gauthier, P. (2006) · Current Applied Physics · doi:10.1016/j.cap.2005.11.026 · Cited by 29
Computer simulations and performance measurements on a silicon strip detector for edge-on imaging
Lundqvist, M., Cederström, B., Chmill, V., Danielsson, M. E., & Nygren, D. R. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873002 · Cited by 29
FTICR analysis of the magnetic trapping mode of the electron beam ion trap
Beiersdörfer, P., Beck, B., Becker, S., & Schweikhard, L. (1996) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04406-0 · Cited by 29
Cheng, W., Zhao, F., Zhang, T., He, Y., & Zhu, H. (2025) · Nanotechnology · doi:10.1088/1361-6528/adb8f2 · Cited by 32
“Radiation detectors interact with these forms of radiation to generate electron–hole pairs in semi-conductor materials, which produce an induced current per the Shockley–Ramo Theorem [3–5].”
Arora, M. M., Balogh, L., Beaufort, C., Brossard, A., Chapellier, M. P., Clarke, J., Corcoran, E. C., Coquillat, J.-M., Dastgheibi-Fard, A., Deng, Y., et al. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.141002 · Cited by 32
“Electron multiplication occurring near an anode induces also a smaller signal of opposite polarity to the other anodes, as expected by the Shockley-Ramo theorem [24, 25] and discussed in Ref.”
Simulation and design of folded perovskite x-ray detectors
Mescher, H., Hamann, E., & Lemmer, U. (2019) · Scientific Reports · doi:10.1038/s41598-019-41440-6 · Cited by 31
Nonlinear nanoelectrodynamics of a Weyl metal
Shao, Y., Jing, R., Chae, S. H., Wang, C., Sun, Z., Emmanouilidou, E., Xu, S., Halbertal, D., Li, B., Rajendran, A., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2116366118 · Cited by 30
Modeling of current–voltage characteristics of thin film solar cells
Mannan, M. A., Anjan, M. S., & Kabir, M. Z. (2011) · Solid-State Electronics · doi:10.1016/j.sse.2011.05.010 · Cited by 28
Effect of repeated x‐ray exposure on the resolution of amorphous selenium based x‐ray imagers
Kabir, M. Z., Chowdhury, L., DeCrescenzo, G., Tousignant, O., Kasap, S. O., & Rowlands, J. A. (2010) · Medical Physics · doi:10.1118/1.3326947 · Cited by 28
Abbene, L., Gerardi, G., Principato, F., Bettelli, M., Seller, P., Veale, M. C., Fox, O., Sawhney, K. J. S., Zambelli, N., Benassi, G., et al. (2018) · Journal of Synchrotron Radiation · doi:10.1107/s1600577518006422 · Cited by 29
“Therefore, in agreement with the Shockley–Ramo theorem (He, 2001; Knoll, 2000; Ramo, 1939; Shockley, 1938), the charge induced on a collecting pixel, proportional to the weighting potential, is mostly contributed from the drift of charge carriers close to the pixel.”
Subpixel resolution in CdTe Timepix3 pixel detectors
Khalil, M., Dreier, E. S., Kehres, J., Jakubek, J., & Olsen, U. L. (2018) · Journal of Synchrotron Radiation · doi:10.1107/s1600577518013838 · Cited by 31
“Charge induction on the electrodes/pixels is caused by this drift and is proportional to the energy deposition of the X-ray (Shockley, 1938; Ramo, 1939).”
MethodOptimized terminal current calculation for Monte Carlo device simulation
Yoder, P. D., Gärtner, K., Krumbein, U., & Fichtner, W. (1997) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/43.662672 · Cited by 28
Photon-assisted resonant transport through a multi-terminal mesoscopic system
Zhao, H.-K. (1997) · Zeitschrift für Physik B Condensed Matter · doi:10.1007/s002570050306 · Cited by 28
Grinberg, A. A., & Luryi, S. (1993) · IEEE Transactions on Electron Devices · doi:10.1109/16.223713 · Cited by 28
Electron-beam charging of polyethylene terephthalate films
Taylor, D. M. (1976) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/9/15/018 · Cited by 28
Theoretical and experimental investigations of subpicosecond photoconductivity
Chamoun, S., Joshi, R. P., Arnold, E., Grondin, R., Meyer, K. E., Pessot, M. A., & Mourou, G. A. (1989) · Journal of Applied Physics · doi:10.1063/1.343918 · Cited by 28
4D tracking: present status and perspectives
Cartiglia, N., Arcidiacono, R., Costa, M. J., Ferrero, M., Gioachin, G., Mandurrino, M., Menzio, L., Siviero, F., Sola, V., & Tornago, M. (2022) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2022.167228 · Cited by 31
“The shape of the induced current signal can be calculated using the Ramo-Shockley theorem [6, 7].”
MethodModeling of current–voltage characteristics of CdS/CdTe solar cells
Anjan, M. S., & Kabir, M. Z. (2011) · physica status solidi (a) · doi:10.1002/pssa.201084069 · Cited by 27
Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy
Amman, M. S., & Luke, P. N. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.407575 · Cited by 29
“With these assumptions, we have calculated the total induced charge pulse height from the even and odd electrodes as a function of the pulse height from the even electrodes alone using the weighting potential method.(28,29) The result of the calculation is the solid line plotted in Figure 7.”
MethodGermanium orthogonal strip detectors with amorphous-semiconductor contacts
Luke, P. N., Amman, M. S., Phlips, B. F., Johnson, W. N., III, & Kroeger, R. A. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.872978 · Cited by 29
Silicon Strip Detectors for Scanned Multi-Slit X-Ray Imaging
Lundqvist, M. (2003) · Cited by 27
Resistive and sympathetic cooling of highly-charged-ion clouds in a Penning trap
Vogel, M., Häffner, H., Hermanspahn, K., Stahl, S., Steinmann, J., & Quint, W. (2014) · Physical Review A · doi:10.1103/physreva.90.043412 · Cited by 26
Albareda, G., Traversa, F. L., Benali, A., & Oriols, X. (2012) · Fluctuation and Noise Letters · doi:10.1142/s0219477512420084 · Cited by 29
Simulation of Silicon Waveguide Single-Photon Avalanche Detectors for Integrated Quantum Photonics
Yanikgonul, S., Leong, V., Ong, J. R., Png, C. E., & Krivitsky, L. A. (2019) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2019.2938439 · Cited by 29
“As such, we use the generalized Shockley-Ramo’s current theorem [27], [28], where each charge carrier i at position ri contributes to the device current I induced on the cathode via:”
MethodDevelopment of a simulation framework for spherical proportional counters
Katsioulas, I., Knights, P., Matthews, J., Neep, T. J., Nikolopoulos, K., Owen, R., & Ward, R. J. (2020) · Journal of Instrumentation · doi:10.1088/1748-0221/15/06/c06013 · Cited by 31
Time-dependent quantum current for independent electrons driven under nonperiodic conditions
Oriols, X., Alarcón, A., & Fernàndez-Díaz, E. (2005) · Physical Review B · doi:10.1103/physrevb.71.245322 · Cited by 26
Simulation of 3D electrostatic configuration in gaseous detectors
Majumdar, N., & Mukhopadhyay, S. (2007) · Journal of Instrumentation · doi:10.1088/1748-0221/2/09/p09006 · Cited by 28
“The weighting field calculation turns out to be equally important in terms of accuracy when signal generation in a gaseous detector is studied foll owing Shockley-Ramo theorem [15, 16].”
BackgroundSimulation and Design of Orthogonal Capacitive Strip CdZnTe Detectors
Montémont, G., Gentet, M.-C., Monnet, O., Rustique, J., & Verger, L. (2007) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2007.902356 · Cited by 27
“We introduce [6], [7] the weighting potential by setting on the electrode , elsewhere.”
MethodCharacterization of Bulk and Surface Transport Mechanisms by Means of the Photocurrent Technique
Zanichelli, M., Pavesi, M., Zappettini, A., Marchini, L., Auricchio, N., Caroli, E., & Manfredi, M. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2009.2032098 · Cited by 28
“Holes and electrons contribute to the photocurrent with weights proportional to the length of path covered in the device [18],”
BackgroundTime-dependent current partition in mesoscopic conductors
Büttiker, Μ. (1995) · Il Nuovo cimento della Società italiana di fisica. B/Il Nuovo cimento B · doi:10.1007/bf02741461 · Cited by 32
Theory of quadrupole detection fourier transform-ion cyclotron resonance
Schweikhard, L. (1991) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(91)80064-t · Cited by 30
Monte Carlo study of shot-noise suppression in semiconductor heterostructure diodes
Reklaitis, A., & Reggiani, L. (1999) · Physical review. B, Condensed matter · doi:10.1103/physrevb.60.11683 · Cited by 26
Performance of CdZnTe geometrically weighted semiconductor Frisch grid radiation detectors
McGregor, D. S., & Rojeski, R. A. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775523 · Cited by 29
Jefferts, S. R., Heavner, T., Hayes, P., & Dunn, G. H. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144153 · Cited by 25
Cooper, R. J., Amman, M. S., Luke, P. N., & Vetter, K. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.05.053 · Cited by 28
Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT Systems
Pretorius, P. H., Liu, C., Fan, P., Peterson, M., & Ljungberg, M. H. (2015) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2015.2433533 · Cited by 28
“After the photon history was completed by either an escape of the detector or photo absorption, induced charge clouds were simulated from the stored interaction sites using both electrons and holes [35] and the simplified formulation for electrons only [38].”
MethodMonocrystalline ZnSe as an ionising radiation detector operated over a wide temperature range
Brodyn, M. S., Degoda, V. Y., Sofiienko, A., Кожушко, Б. В., & Весна, В. Т. (2014) · Radiation Measurements · doi:10.1016/j.radmeas.2014.04.016 · Cited by 25
Bornefalk, H., Xu, C., Svensson, C. M., & Danielsson, M. E. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.04.071 · Cited by 27
Bratina, G., & Pavlica, E. (2018) · Organic Electronics · doi:10.1016/j.orgel.2018.09.049 · Cited by 27
Bäni, L., Alexopoulos, A., Artuso, M., Bachmair, F., Bartosik, M., Beck, H. C., Bellini, V., Belyaev, V., Bentele, B., Bès, A., et al. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab37c6 · Cited by 28
“The average total distance the electron and hole move apart after being created, λ, which is related to the average signal charge observed by the Shockley–Ramo theorem [38, 39], is given by the sum λ = λe + λh.”
MethodUltra-Fast Silicon Detectors for 4D tracking
Sola, V., Arcidiacono, R., Bellora, A., Cartiglia, N., Cenna, F., Cirio, R., Durando, S., Ferrero, M., Galloway, Z., Gruey, B., et al. (2017) · Journal of Instrumentation · doi:10.1088/1748-0221/12/02/c02072 · Cited by 30
“(v) In every particle detector, the shape of the induced current signal can be calculated using the Shockley-Ramo [13, 14] theorem that states that the current induced by a charge carrier is proportional to its electric charge q, the drift velocity v and the weighting field Ew: i = −q~v · ~Ew .”
MethodStandardized workflow for multiplexed charge detection mass spectrometry on orbitrap analyzers
Su, P., McGee, J. P., Hollas, M. A. R., Fellers, R. T., Durbin, K. R., Greer, J. B., Early, B. P., Yip, P. F., Zabrouskov, V., Srzentić, K., et al. (2025) · Nature Protocols · doi:10.1038/s41596-024-01091-y · Cited by 25
“…(ELIT) 10,40–43 is a mainstream CDMS instrumentation platform that simultaneously determines the m/z of an ion from the frequency of oscillation between a pair of electrostatic ion mirrors, and ion charge from the induced image charge on a cylindrical metal tube as the ion passes through it 44,45 .”
Dramatic Improvement in Sensitivity with Pulsed Mode Charge Detection Mass Spectrometry
Todd, A. R., & Jarrold, M. F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03586 · Cited by 24
Space-Charge Limited Current From a Finite Emitter in Nano- and Microdiodes
Gunnarsson, J. B., Torfason, K., Manolescu, A. R., & Valfells, Á. (2020) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2020.3037280 · Cited by 26
Computation of quantum electron transport with local current conservation using quantum trajectories
Alarcón, A., & Oriols, X. (2009) · Journal of Statistical Mechanics Theory and Experiment · doi:10.1088/1742-5468/2009/01/p01051 · Cited by 30
Unipolar time-differential charge sensing in non-dispersive amorphous solids
Goldan, A. H., Rowlands, J. A., Tousignant, O., & Karim, K. S. (2013) · Journal of Applied Physics · doi:10.1063/1.4807292 · Cited by 26
Pellegrini, B. (2013) · The European Physical Journal B · doi:10.1140/epjb/e2013-40571-7 · Cited by 26
Quantum Interfaces Between Atomic and Solid-State Systems
Daniilidis, N., & Häffner, H. (2013) · Annual Review of Condensed Matter Physics · doi:10.1146/annurev-conmatphys-030212-184253 · Cited by 30
“between the electrodes which pick up the electrical signal by a geometric factor of order unity [80, 81].”
BackgroundTracking the Magnetron Motion in FT-ICR Mass Spectrometry
Jertz, R., Friedrich, J., Kriete, C., Николаев, Е. Н., & Baykut, G. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1148-4 · Cited by 27
“Image charges, which are induced at the ICR cell detection electrodes during the FT-ICR detection were simulated by means of the principle of reciprocity [35, 36].”
MethodCdTe and CdZnTe Semiconductor Detectors for Nuclear Medicine Imaging
Wagenaar, D. J. (2004) · Elsevier eBooks · doi:10.1016/b978-012744482-6.50018-1 · Cited by 31
Cross, J. A. (1985) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/18/12/014 · Cited by 25
Finite-frequency noise in a quantum dot with normal and superconducting leads
Droste, S., Splettstoesser, J., & Governale, M. (2015) · Physical Review B · doi:10.1103/physrevb.91.125401 · Cited by 23
Achillides, Z., Danikas, M. G., & Kyriakides, E. (2017) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2017.006013 · Cited by 25
Groza, M., Krawczynski, H. S., Garson, A., Martin, J., Lee, K., Li, Q., Beilicke, M., Cui, Y., Buliga, V., Guo, M., et al. (2010) · Journal of Applied Physics · doi:10.1063/1.3272882 · Cited by 25
Numerical aspects of noise simulation in MOSFETs by a Langevin–Boltzmann solver
Ruić, D., & Jungemann, C. (2014) · Journal of Computational Electronics · doi:10.1007/s10825-014-0642-4 · Cited by 24
3D Active Edge Silicon Detector Tests With 120 GeV Muons
Vià, C. D., Deile, M., Hasi, J., Kenney, C. J., Kok, A., Parker, S. I., Watts, S. J., Anelli, G., Avati, V., Bassetti, V., et al. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2009.2013951 · Cited by 25
Keifer, D. Z., Alexander, A. W., & Jarrold, M. F. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1582-y · Cited by 23
“The ion passes through a metal tube and the induced charge is detected by a charge-sensitive preamplifier [21, 22].”
BackgroundRyzhii, V., Ryzhii, M., Mitin, V., Shur, M. S., & Otsuji, T. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.16.014001 · Cited by 23
Hendrickson, C. L., Beu, S. C., Blakney, G. T., & Marshall, A. G. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.02.009 · Cited by 23
Operation of resonant-tunnelling oscillators beyond tunnel lifetime limit
Feiginov, M., Sydlo, C., Cojocari, O., & Meissner, P. (2011) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/94/48007 · Cited by 23
Semiconductor Characterization by Scanning Ion Beam Induced Charge (IBIC) Microscopy
Vittone, E. (2013) · ISRN Materials Science · doi:10.1155/2013/637608 · Cited by 26
Invited paper. Avalanche diode oscillators. I. Basic concepts
Culshaw, B., Giblin, R. A., & Blakey, P. A. (1974) · International Journal of Electronics · doi:10.1080/00207217408900569 · Cited by 23
“Linearizing” an ion cyclotron resonance cell
Barlow, S. E., & Tinkle, M. D. (2002) · Review of Scientific Instruments · doi:10.1063/1.1518787 · Cited by 23
Chapter 10 Gallium Arsenide Radiation Detectors and Spectrometers
McGregor, D. S., & Kammeraad, J. E. (1995) · Semiconductors and semimetals · doi:10.1016/s0080-8784(08)62749-0 · Cited by 25
Ultrafast and Local Optoelectronic Transport in Topological Insulators
Kiemle, J., Seifert, P., Holleitner, A. W., & Kastl, C. (2020) · physica status solidi (b) · doi:10.1002/pssb.202000033 · Cited by 22
Collision cross section measurements for biomolecules within a high-resolution FT-ICR cell: theory
Guo, D., Xin, Y., Li, D., & Xu, W. L. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c4cp06065b · Cited by 22
Metadata
- Authors
- Shockley, W.
- Affiliations
- Bell Telephone Laboratories, Inc., New York, N. Y.
- Corresponding author
- Shockley, W.
- ORCID
- Shockley, W.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1938-10-01
- Volume
- 9
- Issue
- 10
- Pages
- 635-636
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2091628914
- Cited by
- 1,300
- References
- 1
- Citations by year
- 2026: 42 · 2025: 44 · 2024: 53 · 2023: 63 · 2022: 64 · 2021: 55 · 2020: 116 · 2019: 56 · 2018: 67 · 2017: 50 · 2016: 39 · 2015: 43 · 2014: 47 · 2013: 40 · 2012: 47
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physics (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum and Classical Electrodynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Electromagnetic Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Electromagnetic Scattering and Analysis
- Keywords
- moving point charge, induced current, conductors, external circuit, electromagnetic induction, induced voltage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.