Currents to Conductors Induced by a Moving Point Charge
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
General expressions are derived for the currents which flow in the external circuit connecting a system of conductors when a point charge is moving among the conductors. The results are applied to obtain explicit expressions for several cases of practical interest.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Any form of particle detection and cooling with resonant circuits is based on the fact that the motion of charged particles in a Penning trap induces image currents in the conducting electrodes of the trap (Shockley-Ramo theorem [11,12]).”
From Off-resonance electronic detection and cooling of ions in a Penning trap (2024) · cites this paper as [11]
Citations
Cites
Fundamentals of engineering electronics
Dow, W. G. (1953) · Journal of the Franklin Institute · doi:10.1016/0016-0032(53)90758-3 · Cited by 43
Cited by
Items 301–400 of 1,000
Grassi, L., Forneris, J., Torresi, D., Acosta, L., Pietro, A. D., Figuera, P., Fisichella, M., Grilj, V., Jakšić, M., Lattuada, M., et al. (2014) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2014.08.009 · Cited by 22
Analysis of photoconductive mechanisms of organic-on-inorganic photodiodes
Ocaya, R. O., Dere, A., Al-Sehemi, A. G., Al‐Ghamdi, A. A., Soylu, M., & YAKUPHANOĞLU, F. (2017) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2017.06.024 · Cited by 22
Monte Carlo investigation of current voltage and avalanche noise in GaN double-drift impact diodes
Reklaitis, A., & Reggiani, L. (2005) · Journal of Applied Physics · doi:10.1063/1.1853498 · Cited by 24
Fabrication and spectroscopy results of mercuric iodide Frisch collar detectors
Ariesanti, E., Kargar, A., & McGregor, D. S. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.09.075 · Cited by 23
Design and performance of an ionisation chamber for the measurement of low alpha-activities
Hartmann, A., Hutsch, J., Krüger, F., Sobiella, M., Wilsenach, H., & Zuber, K. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.01.033 · Cited by 23
“As mentioned previously, the signal induced on the anode and the grid is due to the drifting of the ions (that are produced in the initial interaction process) caused by the electric field, and can be described by the ShockleyRamo theorem [18][19].”
MethodVittone, E., Pastuović, Ž., Breese, M. B. H., López, J. G., Jakšić, M., Räisänen, J., Siegele, R., Simon, A., & Vizkelethy, G. (2016) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2016.01.030 · Cited by 25
“the “Shockley-Ramo” theorem [22][23][24][25].”
Geometrically weighted semiconductor Frisch grid radiation spectrometers
McGregor, D. S., Rojeski, R. A., He, Z. J., Wehe, D. K., Driver, M. C., & Blakely, M. (1999) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(98)00948-6 · Cited by 27
Transients in Townsend Discharges
Newton, R. R. (1948) · Physical Review · doi:10.1103/physrev.73.570 · Cited by 22
1-μm spatial resolution in silicon photon-counting CT detectors
Sundberg, C., Persson, M., Wikner, J. J., & Danielsson, M. E. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.6.063501 · Cited by 27
Current–time characteristic of the transient regime of electrohydrodynamic flow formation
Чирков, В. А., & Stishkov, Y. K. (2012) · Journal of Electrostatics · doi:10.1016/j.elstat.2012.12.005 · Cited by 21
An experimental characterisation of a Broad Energy Germanium detector
Harkness-Brennan, L. J., Judson, D. S., Boston, A. J., Boston, H. C., Colosimo, S., Cresswell, J. R., Nolan, P. J., Adekola, A. S., Colaresi, J. F., Cocks, J. F. C., et al. (2014) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2014.05.080 · Cited by 23
Dannheim, D., Dort, K., Hynds, D., Münker, M., Nürnberg, A., Snoeys, W., & Spannagel, S. (2020) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2020.163784 · Cited by 27
“This approximation is valid since the Shockley– Ramo weighting field [16,17] is negligible in most of the sensor volume owing to the small ratio between signal collection electrode size and sensor thickness.”
BackgroundSuntornwipat, N., Majdi, S., Gabrysch, M., Kovi, K. K., Djurberg, V., Friel, I., Twitchen, D. J., & Isberg, J. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c04712 · Cited by 23
Pulse shape analysis for γ-ray tracking (Part I): Pulse shape simulation with JASS
Schlarb, M., Gernhäuser, R., Klupp, S., & Krücken, R. (2011) · The European Physical Journal A · doi:10.1140/epja/i2011-11132-2 · Cited by 22
Direct conversion X-ray sensors: sensitivity, DQE and MTF
Kabir, M. Z., Kasap, S. O., Zhao, W., & Rowlands, J. A. (2003) · IEE Proceedings - Circuits Devices and Systems · doi:10.1049/ip-cds:20030663 · Cited by 31
Forneris, J., Giudice, A. L., Olivero, P., Picollo, F., Re, A., Marinelli, M., Pompili, F., Verona, C., Verona-Rinati, G., Benetti, M., et al. (2014) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/108/18001 · Cited by 21
Chang, L., Asaka, K., Zhu, Z., Wang, Y., Chen, H., & Li, D. (2014) · Journal of Applied Physics · doi:10.1063/1.4884675 · Cited by 21
Guni, E., Durst, J., Kreisler, B., Michel, T., Anton, G., Fiederle, M., Fauler, A., & Zwerger, A. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2010.2095883 · Cited by 24
“In this area—where the biggest part of the signal is induced because of the small pixel effect [10], [11]—the charge carriers stay longer and the probability that they get trapped before they reach the electrode pad is increased.”
BackgroundMethodNew Position Algorithms for the 3D CZT Drift Detector
Budtz-Jørgensen, C., & Kuvvetli, I. (2017) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2017.2696574 · Cited by 21
“This behavior of the cathode strip signals can be explained with the help of the Shockley–Ramon theorem [4].”
MethodHuntington, A. S., Williams, G. M., & Lee, A. O. (2018) · Optical Engineering · doi:10.1117/1.oe.57.7.073106 · Cited by 21
Terras, R., & Swanson, R. A. (1980) · Journal of Mathematical Physics · doi:10.1063/1.524723 · Cited by 21
Welch, H. W. (1953) · Proceedings of the IRE · doi:10.1109/jrproc.1953.274191 · Cited by 28
Determination of Air Velocity by Ion Transit-Time Measurements
Cooley, W. C., & Stever, H. G. (1952) · Review of Scientific Instruments · doi:10.1063/1.1746212 · Cited by 21
Boron-10 layers, Neutron Reflectometry and Thermal Neutron Gaseous DetectorsPreprint
Piscitelli, F. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1406.3133 · Cited by 26
“The method to calculate the induced charge on electrodes due to the motion of charges in a detector makes use of the Shockley-Ramo theorem [16], [17], [18] and the concept of the weighting field.”
MethodHuang, C., Yin, H., Xu, P., Zhang, B., He, J., & Liu, J. (2020) · High Voltage · doi:10.1049/hve.2019.0050 · Cited by 21
Harmonic Generation in Multipactor Discharges
Wong, P. Y., Zhang, P., & Verboncoeur, J. P. (2020) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2020.2980482 · Cited by 20
“It should be noted that the current induced in the external circuit calculated via the Shockley–Ramo Theorem [25], [26] [shown in black in Figs.”
MethodKobayashi, M., Angelone, M., Yoshihashi, S., Ogawa, K., Isobe, M., Nishitani, T., Sangaroon, S., Kamio, S., Fujiwara, Y., Tsubouchi, T., et al. (2020) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2020.112063 · Cited by 20
Charge collection and absorption-limited x-ray sensitivity of pixellated x-ray detectors
Kabir, M. Z., & Kasap, S. O. (2004) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.1647588 · Cited by 22
Liu, Y., Zhou, L., Liu, Y., Yuan, H., & Ji, L. (2017) · Physics of Plasmas · doi:10.1063/1.4999228 · Cited by 20
Modeling Photon Counting Detector Anode Street Impact on Detector Energy Response
Lai, X., Shirono, J., Araki, H., Budden, B., Cai, L., Kawata, G., Miyazaki, H., Qiang, Y., Ye, Z., Zhan, X., et al. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3013245 · Cited by 20
Charge Sharing and Charge Loss in High-Flux Capable Pixelated CdZnTe Detectors
Koch-Mehrin, K. A. L., Bugby, S. L., Lees, J. E., Veale, M. C., & Wilson, M. D. (2021) · Sensors · doi:10.3390/s21093260 · Cited by 20
“This effect changes the weighting potential in the detector such that a significant charge is only induced by charge carriers drifting close to the collecting pixel, described by the Shockley–Ramo theorem [13].”
MethodQuantum logic inspired techniques for spacetime-symmetry tests with (anti-)protons
Cornejo, J. M., Lehnert, R., Niemann, M., Mielke, J., Meiners, T., Bautista-Salvador, A., Schulte, M., Nitzschke, D., Borchert, M. J., Hammerer, K., et al. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac136e · Cited by 27
Comparative analysis of sequential and coherent tunneling models in resonant diodes
Aleshkin, V. Y., Reggiani, L., & Rosini, M. (2006) · Physical Review B · doi:10.1103/physrevb.73.165320 · Cited by 21
Description of the plasma delay effect in silicon detectors
Sosin, Z. (2012) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2012.07.020 · Cited by 20
High temperature response of a single crystal CVD diamond detector operated in current mode
Angelone, M., Cesaroni, S., Loreti, S., Pagano, G., & Pillon, M. (2019) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2019.162493 · Cited by 20
Discharge studies in solid insulation voids
Danikas, M. G. (2002) · IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) · doi:10.1109/ceidp.1990.201350 · Cited by 20
Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps
Xiang, X., Guan, S., & Marshall, A. G. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85014-3 · Cited by 21
Electronic Hall Effect in NaCl
Redfield, A. G. (1953) · Physical Review · doi:10.1103/physrev.91.753 · Cited by 20
Photoconductivity as a Function of Optical Absorption
Goodman, A. M. (1959) · Journal of Applied Physics · doi:10.1063/1.1735122 · Cited by 20
Majdi, S., Djurberg, V., Suntornwipat, N., Gabrysch, M., & Isberg, J. (2020) · Advanced Theory and Simulations · doi:10.1002/adts.202000103 · Cited by 20
Tsujino, S., Paraliev, M., Kirk, E. C., Gough, C., Ivković, S., & Braun, H.-H. (2011) · Physics of Plasmas · doi:10.1063/1.3594579 · Cited by 19
Microreversibility, fluctuations, and nonlinear transport in transistors
Gu, J., & Gaspard, P. (2019) · Physical review. E · doi:10.1103/physreve.99.012137 · Cited by 23
Spectral correction algorithm for multispectral CdTe x-ray detectors
Christensen, E. D., Gu, Y., Kehres, J., Feidenhans’l, R., & Olsen, U. L. (2017) · Radiation Detectors in Medicine, Industry, and National Security · doi:10.1117/12.2272935 · Cited by 19
“The induced charge Q on an electrode due to moving charges in the active detector volume is described by the Shockley-Ramo theorem 14,25,26 where N 0 is the number of charge carrier, q is the charge of the carriers, and ∆ ϕ 0 is the weighting potential difference from start to end of the charge…”
BackgroundExact Solution for Driven Oscillations in Plasmonic Field-Effect Transistors
Svintsov, D. A. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.024037 · Cited by 21
Abbene, L., & Sordo, S. D. (2014) · Elsevier eBooks · doi:10.1016/b978-0-444-53632-7.00619-5 · Cited by 21
Grönlund, T., Li, Z., Carini, G. A., & Li, M. (2008) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.12.005 · Cited by 22
Improved Calculation of Corona Pulse Characteristics
Khalifa, M., & Abdel‐Salam, M. (1974) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1974.293902 · Cited by 20
On the electrodynamics of partial discharges in voids in solid dielectrics
Pedersen, A. (1989) · IEEE International Conference on Solid Dielectrics · doi:10.1109/icsd.1989.69171 · Cited by 22
On the signal collection in laser enhanced ionization spectrometry
Magnusson, I. (1987) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/0584-8547(87)80157-x · Cited by 19
Jackson, G. S., Canterbury, J. D., Guan, S., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00232-2 · Cited by 19
Stability of polarized states for diamond valleytronics
Hammersberg, J., Majdi, S., Kovi, K. K., Suntornwipat, N., Gabrysch, M., Twitchen, D. J., & Isberg, J. (2014) · Applied Physics Letters · doi:10.1063/1.4882649 · Cited by 19
Astroparticle physics with a customized low-background broad energy Germanium detector
Aalseth, C. E., Amman, M. S., Avignone, F. T., III, Back, H. O., Barabash, A. S., Barbeau, P. S., Bergevin, M., Bertrand, F. E., Boswell, M., Brudanin, V. B., et al. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.08.100 · Cited by 18
Pulse-shape analysis in Cd0.9Zn0.1Te0.98Se0.02 room-temperature radiation detectors
Chaudhuri, S. K., Sajjad, M., & Mandal, K. C. (2020) · Applied Physics Letters · doi:10.1063/5.0003646 · Cited by 19
A spectroscopic Monte-Carlo model to simulate the response of pixelated CdTe based detectors
Koch-Mehrin, K. A. L., Lees, J. E., & Bugby, S. L. (2020) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2020.164241 · Cited by 18
Cadmium Zinc Telluride detectors for a next-generation hard X-ray telescope
Tang, J., Kislat, F., & Krawczynski, H. S. (2021) · Astroparticle Physics · doi:10.1016/j.astropartphys.2021.102563 · Cited by 18
Asanovski, R., Palestri, P., Caruso, E., & Selmi, L. (2021) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2021.3104790 · Cited by 20
Pomorski, M., Delfaure, C., Vaissière, N. I., Bensalah, H., Barjon, J., Pinault-Thaury, M. A., Tromson, D., & Bergonzo, P. (2015) · physica status solidi (a) · doi:10.1002/pssa.201532230 · Cited by 18
Goldan, A. H., Tousignant, O., Laperrière, L., & Karim, K. S. (2010) · Applied Physics Letters · doi:10.1063/1.3302454 · Cited by 19
Alexander, J., Graham, L. M., Calvert, C. R., Kelly, O., King, R. B., Williams, I. D., & Greenwood, J. B. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/4/045802 · Cited by 18
“Green’s reciprocity Theorem [17] states that the ratio of the potential at a point P in space, relative to the ring potential, is equal to the negative of the ratio of charge imaged on the ring by a charge present at P.”
BackgroundDong, B., Lei, X. L., & Horing, N. J. M. (2008) · Journal of Applied Physics · doi:10.1063/1.2967710 · Cited by 18
Tsujino, S., Paraliev, M., Kirk, E. C., Vogel, T., Pimpec, F. L., Gough, C., Ivković, S., & Braun, H.-H. (2011) · Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena · doi:10.1116/1.3569820 · Cited by 18
A low-noise, wideband preamplifier for a fourier-transform ion cyclotron resonance mass spectrometer
Mathur, R., Knepper, R. W., & O’Connor, P. B. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.09.013 · Cited by 18
“The theory was based on the work of Shockley, who calculated the induced current in electrodes in proximity of a moving charge [22].”
MethodGazaryan, A. V., Ситников, А. А., Чирков, В. А., & Stishkov, Y. K. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2680398 · Cited by 18
“(1)–(8) and the Shockley-Ramo theorem [14, 15] also known as the Sato’s equation (10) [16].”
BackgroundPulse-height defect of Ar + CF 4 mixtures as a counting gas for fission-fragment detectors
Peck, M., Göök, A., Enders, J., Hambsch, F.-J., & Oberstedt, S. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.12.060 · Cited by 18
Single carrier sensing techniques in compound semiconductor detectors
Owens, A., & Kozorezov, A. G. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.01.101 · Cited by 20
Misharin, A. S., & Zubarev, R. A. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2724 · Cited by 18
Detection and Electrical Characterization of Defects at the SiO2/4H-SiC Interface
Krieger, M., Beljakowa, S., Zippelius, B., Afanas'ev, V. V., Bauer, A. J., Nanen, Y., Kimoto, T., & Pensl, G. (2010) · Materials science forum · doi:10.4028/www.scientific.net/msf.645-648.463 · Cited by 22
Edge and corner effects on spectra of segmented CdZnTe detectors
Mardor, I., Shor, A., & Eisen, Y. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.958719 · Cited by 19
Hofstadter, R. (1950) · Proceedings of the IRE · doi:10.1109/jrproc.1950.233431 · Cited by 18
Sympathetic cooling schemes for separately trapped ions coupled via image currents
Will, C., Bohman, M., Driscoll, T., Wiesinger, M., Abbass, F., Borchert, M. J., Devlin, J. A., Erlewein, S., Fleck, M., Latacz, B. M., et al. (2022) · New Journal of Physics · doi:10.1088/1367-2630/ac55b3 · Cited by 19
“Here D is a specific length related to the trap size and the chosen pickup geometry [28, 29] and can be considered an ‘effective electrode distance’.”
BackgroundLearning-based physical models of room-temperature semiconductor detectors with reduced data
Banerjee, S., Rodrigues, M. L., Ballester, M., Vija, A. H., & Katsaggelos, A. K. (2023) · Scientific Reports · doi:10.1038/s41598-022-27125-7 · Cited by 19
Realization of Higher Resolution Charge Detection Mass Spectrometry
Reitenbach, D. W., Botamanenko, D. Y., Miller, L. M., & Jarrold, M. F. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c03267 · Cited by 17
Quantum ballistic channel as an ultrahigh frequency generator
Fedichkin, L. E., & Vyurkov, V. (1994) · Applied Physics Letters · doi:10.1063/1.111565 · Cited by 17
Чирков, В. А., Stishkov, Y. K., & Ситников, А. А. (2015) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2015.005110 · Cited by 18
“There are several ways to calculate the total value of the electric current passing through the external electrical circuit, but the most convenient and reliable one in the unsteady-state regime is the approach based on the Shockley–Ramo theorem [15–17].”
MethodSpace charge polarization in irradiated single crystal CVD diamond
Naaranoja, T., Golovleva, M., Martikainen, L., Berretti, M., & Österberg, K. (2019) · Diamond and Related Materials · doi:10.1016/j.diamond.2019.03.007 · Cited by 18
“Using Shockley-Ramo theorem [13,14], the electric field inside the detector can be deduced.”
MethodPhotoconductivity: Fundamental Concepts
Kasap, S. O. (2022) · Wiley eBooks · doi:10.1002/9781119579182.ch1 · Cited by 20
Harper, C. C., Miller, Z. M., & Williams, E. R. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c03160 · Cited by 17
Influence of spin waves on transport through a quantum-dot spin valve
Sothmann, B., König, J., & Kadigrobov, A. M. (2010) · Physical Review B · doi:10.1103/physrevb.82.205314 · Cited by 19
Jonasson, O., & Knežević, I. (2014) · Physical Review B · doi:10.1103/physrevb.90.165415 · Cited by 18
Theoretical Comparison between the Flicker Noise Behavior of Graphene and of Ordinary Semiconductors
Macucci, M., & Marconcini, P. (2020) · Journal of Sensors · doi:10.1155/2020/2850268 · Cited by 18
“charges) [74]; E ðx, yÞ is the electric field actually present in the device; μn (μp) and n (p) are the mobilities and surface densities of electrons (holes); and A is the area of the device, equal to the product of the width W and the length L.”
BackgroundMethodSemiconductor Radiation Detectors
McGregor, D. S. (2021) · Springer eBooks · doi:10.1007/978-3-319-47999-6_16-2 · Cited by 17
Bibliography on extra-high-voltage systems
Abetti, P. A. (1958) · Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems · doi:10.1109/aieepas.1958.4500194 · Cited by 17
Apparatus for Measurement of Transport Properties of Photocarriers in Insulating Crystals
Borders, J. A., & Hodby, J. W. (1968) · Review of Scientific Instruments · doi:10.1063/1.1683484 · Cited by 17
Calculation of transient photocurrents in insulators with trapped space charge
Hermann, A. M. (1973) · Journal of Applied Physics · doi:10.1063/1.1662293 · Cited by 17
Ionic-electrostatic modeling of solid-liquid triboelectric nanogenerators
Wang, B., Zhao, H., Jin, C., Xu, Y., & Ding, W. (2026) · Iontronics · doi:10.20517/iontronics.2026.009 · Cited by 19
Proximity Charge Sensing With Semiconductor Detectors
Luke, P. N., Tindall, C., & Amman, M. S. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.2011483 · Cited by 18
“Shockley-Ramo theorem [4], [5], and it can be calculated using the weighting potential method:”
MethodThe Thick Gas Electron Multiplier and its derivatives: Physics, technologies and applications
Bressler, S., Moleri, L., Jash, A., Tesi, A., & Zavazieva, D. (2023) · Progress in Particle and Nuclear Physics · doi:10.1016/j.ppnp.2023.104029 · Cited by 17
Guo, R., Xu, Y., Wang, T., Zha, G., & Jie, W. (2020) · Journal of Applied Physics · doi:10.1063/1.5126792 · Cited by 16
Kim, C., & Hwang, J. (2012) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/45/46/465204 · Cited by 17
Characterization of CdMnTe radiation detectors using current and charge transients
Rafiei, R., Reinhard, M. I., Sarbutt, A., Uxa, Š., Boardman, D., Watt, G. C., Belas, E., Kim, K., Bolotnikov, A. E., & James, R. B. (2013) · Journal of Semiconductors · doi:10.1088/1674-4926/34/7/073001 · Cited by 16
High-frequency properties of a graphene nanoribbon field-effect transistor
Ryzhii, M., Satou, A., Ryzhii, V., & Otsuji, T. (2008) · Journal of Applied Physics · doi:10.1063/1.3029715 · Cited by 17
Different avalanche types in electronegative gases
Wetzer, J. M., & Wen, C. (1991) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/24/11/010 · Cited by 17
Transport equations and Ramo's theorem
Dąbrowski, W. (1989) · Progress in Quantum Electronics · doi:10.1016/0079-6727(89)90004-9 · Cited by 16
Pellegrini, B., Marconcini, P., Macucci, M., Fiori, G., & Basso, G. (2016) · Journal of Statistical Mechanics Theory and Experiment · doi:10.1088/1742-5468/2016/05/054017 · Cited by 16
“This can be related to the current at the terminals via the electrokinematics theorem [9], which is an extension of the Ramo–Shockley theorem [10, 11].”
BackgroundChen, R., Guan, S., & Marshall, A. G. (1994) · The Journal of Chemical Physics · doi:10.1063/1.466524 · Cited by 16
A two-electrode ion trap for Fourier transform ion cyclotron resonance mass spectrometry
Marto, J. A., Marshall, A. G., & Schweikhard, L. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)85008-9 · Cited by 16
Electron-beam-induced conductivity in thin insulating films
Taylor, D. M. (1979) · Radiation Physics and Chemistry (1977) · doi:10.1016/0146-5724(79)90048-7 · Cited by 16
Solution of the Space Charge Problem for a Pulsed Townsend Discharge
Morrison, J. A., & Edelson, D. (1962) · Journal of Applied Physics · doi:10.1063/1.1728814 · Cited by 16
Streamer current in a three-electrode system
Akyuz, M., Gao, L., Cooray, V., & Larsson, A. (2001) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.946721 · Cited by 16
Evaluating the performance of semiconductor radiation detectors through static charge analysis
Lingren, C. L., & Butler, J. F. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.685294 · Cited by 18
Metadata
- Authors
- Shockley, W.
- Affiliations
- Bell Telephone Laboratories, Inc., New York, N. Y.
- Corresponding author
- Shockley, W.
- ORCID
- Shockley, W.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1938-10-01
- Volume
- 9
- Issue
- 10
- Pages
- 635-636
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2091628914
- Cited by
- 1,300
- References
- 1
- Citations by year
- 2026: 42 · 2025: 44 · 2024: 53 · 2023: 63 · 2022: 64 · 2021: 55 · 2020: 116 · 2019: 56 · 2018: 67 · 2017: 50 · 2016: 39 · 2015: 43 · 2014: 47 · 2013: 40 · 2012: 47
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physics (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum and Classical Electrodynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Electromagnetic Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Electromagnetic Scattering and Analysis
- Keywords
- moving point charge, induced current, conductors, external circuit, electromagnetic induction, induced voltage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.