The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Abstract
A method is given of finding a real function in a finite region of a plane given its line integrals along all straight lines intersecting the region. The solution found is applicable to three problems of interest for precise radiology and radiotherapy: (1) the determination of a variable x-ray absorption coefficient in two dimensions; (2) the determination of the distribution of positron annihilations when there is an inhomogeneous distribution of the positron emitter in matter; and (3) the determination of a variable density of matter with constant chemical composition, using the energy loss of charged particles in the matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Higher Transcendental Functions
Manuscript, B., Bateman, H., & Erdélyi, A. (1981) · Medical Entomology and Zoology · Cited by 7,623
(2005) · Nonlinear Partial Differential Equations for Scientists and Engineers · doi:10.1007/0-8176-4418-0_13 · Cited by 4,134
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Beugungstheorie des schneidenver-fahrens und seiner verbesserten form, der phasenkontrastmethode
Zernike, V. F. (1934) · Physica · doi:10.1016/s0031-8914(34)80259-5 · Cited by 1,058
The Use of Positron-emitting Radioisotopes for the Localization of Brain Tumors
Wrenn, F. R., Good, M. L., & Handler, P. (1951) · Science · doi:10.1126/science.113.2940.525 · Cited by 235
Cited by
3D electron microscopy in the physical sciences: the development of Z-contrast and EFTEM tomography
Midgley, P. A., & Weyland, M. (2003) · Ultramicroscopy · doi:10.1016/s0304-3991(03)00105-0 · Cited by 1,028
Yang, W., Feng, H., Zhang, X., Zhang, J., Doonan, J. H., Batchelor, W. D., Xiong, L., & Yan, J. (2020) · Molecular Plant · doi:10.1016/j.molp.2020.01.008 · Cited by 961
Electron tomography and holography in materials science
Midgley, P. A., & Dunin-Borkowski, R. E. (2009) · Nature Materials · doi:10.1038/nmat2406 · Cited by 883
Three-Dimensional X-Ray Microtomography
Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987) · Science · doi:10.1126/science.237.4821.1439 · Cited by 773
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689
Metadata
- Authors
- Cormack, A. M.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1963-09-01
- Volume
- 34
- Issue
- 9
- Pages
- 2722-2727
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2004804713
- Cited by
- 1,399
- References
- 6
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.