The DOI matches its Crossref record.
The Oximeter, an Instrument for Measuring Continuously the Oxygen Saturation of Arterial Blood in Man
Abstract
The oxygen saturation of arterial blood in man can be measured continuously in situ by means of bichromatic photoelectric colorimetry of the intact fully flushed ear. The accuracy of the device as determined by gas analysis of arterial blood samples is from 3 to 8 percent. The entire optical and photoelectric system, comprising a miniature lamp bulb, two color filters, and two selenium barrier-layer photo-cells, weighs 30 grams, and slips over the shell of the ear. One of the color filters transmits a wave-length band which is equally absorbed by oxy- and reduced hemoglobin, thus providing a means of measuring the amount of total hemoglobin in the optical path, independent of its degree of oxygen saturation. The other color is very differently absorbed by the two hemoglobin forms. Several direct reading forms of the instrument are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
A NIRS-fMRI investigation of prefrontal cortex activity during a working memory task
Sato, H., Yahata, N., Funane, T., Takizawa, R., Katura, T., Atsumori, H., Nishimura, Y., Kinoshita, A., Kiguchi, M., Koizumi, H., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.043 · Cited by 339
Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Metadata
- Authors
- Millikan, G. A.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1942-10-01
- Volume
- 13
- Issue
- 10
- Pages
- 434-444
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2042295435
- Cited by
- 331
- References
- 0
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Oximeter, an Instrument for Measuring Continuously the Oxygen Saturation of Arterial Blood in Man. https://app.cochat.ai/papers/10.1063/1.1769941
- The paper
- Millikan, G. A. (1942). The Oximeter, an Instrument for Measuring Continuously the Oxygen Saturation of Arterial Blood in Man. Review of Scientific Instruments. https://doi.org/10.1063/1.1769941
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.