Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 365

The DOI matches its Crossref record.

Virus detection using nanoelectromechanical devices

Ilic, B., Yang, Y., Craighead, H. G.·2004·Applied Physics Letters

Abstract

We have used a resonating mechanical cantilever to detect immunospecific binding of viruses, captured from liquid. As a model virus, we used a nonpathogenic insect baculovirus to test the ability to specifically bind and detect small numbers of virus particles. Arrays of surface micromachined, antibody-coated polycrystalline silicon nanomechanical cantilever beams were used to detect binding from various concentrations of baculoviruses in a buffer solution. Because of their small mass, the 0.5μm×6μm cantilevers have mass sensitivities on the order of 10−19g∕Hz, enabling the detection of an immobilized AcV1 antibody monolayer corresponding to a mass of about 3×10−15g. With these devices, we can detect the mass of single-virus particles bound to the cantilever. Resonant frequency shift resulting from the adsorbed mass of the virus particles distinguished solutions of virus concentrations varying between 105 and 107pfu∕ml. Control experiments using buffer solutions without baculovirus showed small amounts (<50attograms) of nonspecific adsorption to the antibody layer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1794378

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 365

Metadata

Authors
Ilic, B., Yang, Y., & Craighead, H. G.
Venue
Applied Physics Letters
Published
2004-09-27
Volume
85
Issue
13
Pages
2604-2606
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2018886977
Cited by
365
References
0
FWCI
21.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Virus detection using nanoelectromechanical devices. https://app.cochat.ai/papers/10.1063/1.1794378
The paper
Ilic, B., Yang, Y., & Craighead, H. G. (2004). Virus detection using nanoelectromechanical devices. Applied Physics Letters. https://doi.org/10.1063/1.1794378

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.