The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Virus detection using nanoelectromechanical devices
Abstract
We have used a resonating mechanical cantilever to detect immunospecific binding of viruses, captured from liquid. As a model virus, we used a nonpathogenic insect baculovirus to test the ability to specifically bind and detect small numbers of virus particles. Arrays of surface micromachined, antibody-coated polycrystalline silicon nanomechanical cantilever beams were used to detect binding from various concentrations of baculoviruses in a buffer solution. Because of their small mass, the 0.5μm×6μm cantilevers have mass sensitivities on the order of 10−19g∕Hz, enabling the detection of an immobilized AcV1 antibody monolayer corresponding to a mass of about 3×10−15g. With these devices, we can detect the mass of single-virus particles bound to the cantilever. Resonant frequency shift resulting from the adsorbed mass of the virus particles distinguished solutions of virus concentrations varying between 105 and 107pfu∕ml. Control experiments using buffer solutions without baculovirus showed small amounts (<50attograms) of nonspecific adsorption to the antibody layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
Self-citationNanodevice motion at microwave frequencies
Henry Huang, X. M., Zorman, C. A., Mehregany, M., & Roukes, M. L. (2003) · Nature · doi:10.1038/421496a · Cited by 587
Attogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C., & Neuzil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 585
Self-citationSingle virus particle mass detection using microresonators with nanoscale thickness
Gupta, A., Akin, D., & Bashir, R. (2004) · Applied Physics Letters · doi:10.1063/1.1667011 · Cited by 543
Fabrication of high frequency nanometer scale mechanical resonators from bulk Si crystals
Cleland, A. N., & Roukes, M. L. (1996) · Applied Physics Letters · doi:10.1063/1.117548 · Cited by 538
Single cell detection with micromechanical oscillators
Ilic, B., Czaplewski, D., Zalalutdinov, M., Craighead, H. G., Neuzil, P., Campagnolo, C., & Batt, C. (2001) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.1421572 · Cited by 443
Self-citationSensitive detection of plastic explosives with self-assembled monolayer-coated microcantilevers
Pinnaduwage, L. A., Boiadjiev, V., Hawk, J. E., & Thundat, T. (2003) · Applied Physics Letters · doi:10.1063/1.1602156 · Cited by 200
Biosensor based on force microscope technology
Baselt, D. R., Lee, G. U., & Colton, R. J. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.588714 · Cited by 142
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Analysis of Radiation-Pressure Induced Mechanical Oscillation of an Optical Microcavity
Kippenberg, T. J., Rokhsari, H., Carmon, T., Scherer, A., & Vahala, K. J. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.033901 · Cited by 753
Senaratne, W., Andruzzi, L., & Ober, C. K. (2005) · Biomacromolecules · doi:10.1021/bm050180a · Cited by 695
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Self-citationShanmukh, S., Jones, L., Driskell, J., Zhao, Y., Dluhy, R., & Tripp, R. A. (2006) · Nano Letters · doi:10.1021/nl061666f · Cited by 630
Recent progress in SERS biosensing
Bantz, K. C., Meyer, A. F., Wittenberg, N. J., Im, H., Kurtuluş, Ö., Lee, S. H., Lindquist, N. C., Oh, S.-H., & Haynes, C. L. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp01841d · Cited by 620
Detection Limits for Nanoscale Biosensors
Sheehan, P. E., & Whitman, L. J. (2005) · Nano Letters · doi:10.1021/nl050298x · Cited by 615
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Novel nanostructures for SERS biosensing
Tripp, R. A., Dluhy, R. A., & Zhao, Y. (2008) · Nano Today · doi:10.1016/s1748-0132(08)70042-2 · Cited by 439
Group III nitride and SiC based MEMS and NEMS: materials properties, technology and applications
Cimalla, V, Pezoldt, J., & Ambacher, O. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/20/s19 · Cited by 392
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Fast, Ultrasensitive Virus Detection Using a Young Interferometer Sensor
Ymeti, A., Greve, J., Lambeck, P. V., Wink, T., van Hövell, Beumer, Wijn, R. R., Heideman, R. G., Subramaniam, V., & Kanger, J. S. (2007) · Nano Letters · doi:10.1021/nl062595n · Cited by 287
Metadata
- Authors
- Ilic, B., Yang, Y., & Craighead, H. G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2004-09-27
- Volume
- 85
- Issue
- 13
- Pages
- 2604-2606
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2018886977
- Cited by
- 365
- References
- 9
- FWCI
- 21.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.