Flexible, organic, ion-sensitive field-effect transistor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Organic ion-sensitive field-effect transistors assembled on flexible plastic films have been fabricated. A thin Mylar™ foil acts both as substrate and gate dielectric. The active layer is vacuum-sublimed on one side of the foil, prepatterned with bottom-contact Au source and drain electrodes. The opposite side of the insulating film is in contact with an electrolytic solution that together with a reference electrode forms an ionic gate. A sensitivity of the device to the pH of the electrolyte solution has been observed. Thanks to the flexibility of the substrate and the low cost of the employed technology, this device opens the way for flexible sensors that can be employed in a variety of innovative applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Organic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
Functional Organic Field‐Effect Transistors
Guo, Y., Yu, G., & Liu, Y. (2010) · Advanced Materials · doi:10.1002/adma.201000740 · Cited by 585
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
Electronic Muscles and Skins: A Review of Soft Sensors and Actuators
Chen, D., & Pei, Q. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00019 · Cited by 506
Chemical and biological sensors based on organic thin-film transistors
Mabeck, J. T., & Malliaras, G. G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3390-2 · Cited by 479
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
Kergoat, L., Piro, B., Berggren, M., Horowitz, G., & Pham, M.-C. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5363-y · Cited by 303
Organic Electronics at the Interface with Biology
Owens, R. M., & Malliaras, G. G. (2010) · MRS Bulletin · doi:10.1557/mrs2010.583 · Cited by 294
Glucose sensor based on organic thin film transistor using glucose oxidase and conducting polymer
Liu, J., Agarwal, M., & Varahramyan, K. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.08.009 · Cited by 183
Active Devices Based on Organic Semiconductors for Wearable Applications
Barbaro, M., Caboni, A., Cosseddu, P., Mattana, G., & Bonfiglio, A. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2044798 · Cited by 60
“A second approach, still inspired by the conventional ISFET device, was proposed in 2005 [ 21 ].”
MethodSelf-citation
Metadata
- Authors
- Loi, A., Manunza, I., & Bonfiglio, A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2005-03-04
- Volume
- 86
- Issue
- 10
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2023191307
- Cited by
- 120
- References
- 1
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.