On the measurement of frequency and of its sample variance with high-resolution counters
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A frequency counter measures the input frequency ν¯ averaged over a suitable time τ, versus the reference clock. High resolution is achieved by interpolating the clock signal. Further increased resolution is obtained by averaging multiple frequency measurements highly overlapped. In the presence of additive white noise or white phase noise, the square uncertainty improves from σν2∝1∕τ2 to σν2∝1∕τ3. Surprisingly, when a file of contiguous data is fed into the formula of the two-sample (Allan) variance σy2(τ)=E{12(y¯k+1−y¯k)2} of the fractional frequency fluctuation y, the result is the modified Allan variance mod σy2(τ). But if a sufficient number of contiguous measures are averaged in order to get a longer τ and the data are fed into the same formula, the results is the (nonmodified) Allan variance. Of course interpretation mistakes are around the corner if the counter internal process is not well understood. The typical domain of interest is the the short-term stability measurement of oscillators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692 · cited 1×
“SAMPLE VARIANCES The Allan variance σ(2) y(τ) [6] is the expected variance of two contiguous samples averaged over the time τ”
Cited by
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
High-stability transfer of an optical frequency over long fiber-optic links
Williams, P. A., Swann, W. C., & Newbury, N. R. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001284 · Cited by 385
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Metadata
- Authors
- Rubiola, E.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2005-05-01
- Volume
- 76
- Issue
- 5
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2600059758
- Cited by
- 118
- References
- 1
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the measurement of frequency and of its sample variance with high-resolution counters. https://app.cochat.ai/papers/10.1063/1.1898203
- The paper
- Rubiola, E. (2005). On the measurement of frequency and of its sample variance with high-resolution counters. Review of Scientific Instruments. https://doi.org/10.1063/1.1898203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.