Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 584

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

1.5 μm Lasers with Sub-10 mHz Linewidth

Open access
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., Sterr, U.·2017·Physical Review Letters

Abstract

We report on two ultrastable lasers each stabilized to independent silicon Fabry-Pérot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of the mirror coatings with a flicker noise floor of 4×10^{-17} for integration times between 0.8 s and a few tens of seconds. We rigorously treat the notorious divergences encountered with the associated flicker frequency noise and derive methods to relate this noise to observable and practically relevant linewidths and coherence times. The individual laser linewidth obtained from the phase noise spectrum or the direct beat note between the two lasers can be as small as 5 mHz at 194 THz. From the measured phase evolution between the two laser fields we derive usable phase coherence times for different applications of 11 to 55 s.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.118.263202

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Research works printed but not linked: 11

  1. 10.1117/12.2228825 · doi:10.1117/12.2228825
  2. 10.1063/1.3290631 · doi:10.1063/1.3290631
  3. 10.1103/PhysRevB.92.174113 · doi:10.1103/physrevb.92.174113
  4. 10.1116/1.579036 · doi:10.1116/1.579036
  5. G. Kramer, 2004, Proceedings of the 18th European Frequency and Time Forum, Guildford, UK
  6. J. E. Gray, 1974, Proceedings of the 28th Annual Symposium on Frequency Control, 29-31 May 1974, Atlantic City, New Jersey, New Jersey
  7. 10.1364/JOSA.72.001258 · doi:10.1364/josa.72.001258
  8. 10.1109/PROC.1972.8696 · doi:10.1109/proc.1972.8696
  9. 10.1109/TIM.1981.6312409 · doi:10.1109/tim.1981.6312409
  10. D. W. Allan, 1981, Proceedings of the 35th Ann. Freq. Control Symposium
  11. J. L. Hall, 1992, Laser Manipulation of Atoms and Ions, Proceedings Internat. School of Physics Enrico Fermi, Vol. Course CXVIII

Cited by

See all 584

Metadata

Authors
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., & Sterr, U.
Venue
Physical Review Letters
Published
2017-06-28
Volume
118
Issue
26
Pages
263202-263202
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2963808380
Cited by
584
References
46
FWCI
26.84
Type
journal article
Language
en
Open access
green
Funders
  • National Institute of Standards and Technology
  • Horizon 2020 Framework Programme (15SIB03 OC18)
  • Alexander von Humboldt-Stiftung
  • U.S. Department of Defense
  • Centre for Quantum Engineering and Space-Time Research (QUEST)
  • Physikalisch-Technische Bundesanstalt (PTB)
  • JILA Physics Frontier Center (NSF)
  • EURAMET

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 1.5 μm Lasers with Sub-10 mHz Linewidth. https://app.cochat.ai/papers/10.1103/physrevlett.118.263202
The paper
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., & Sterr, U. (2017). 1.5 μm Lasers with Sub-10 mHz Linewidth. Physical Review Letters. https://doi.org/10.1103/physrevlett.118.263202

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.