The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
1.5 μm Lasers with Sub-10 mHz Linewidth
Open accessAbstract
We report on two ultrastable lasers each stabilized to independent silicon Fabry-Pérot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of the mirror coatings with a flicker noise floor of 4×10^{-17} for integration times between 0.8 s and a few tens of seconds. We rigorously treat the notorious divergences encountered with the associated flicker frequency noise and derive methods to relate this noise to observable and practically relevant linewidths and coherence times. The individual laser linewidth obtained from the phase noise spectrum or the direct beat note between the two lasers can be as small as 5 mHz at 194 THz. From the measured phase evolution between the two laser fields we derive usable phase coherence times for different applications of 11 to 55 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Saleh, B. E. A., & Teich, M. C. (1991) · doi:10.1002/0471213748 · Cited by 3,383
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationInterferometry and Synthesis in Radio Astronomy
Thompson, A. R., Moran, J. M., & Swenson, G. W. (2001) · Wiley eBooks · doi:10.1002/9783527617845 · Cited by 1,446
A fully photonics-based coherent radar system
Ghelfi, P., Laghezza, F., Scotti, F., Serafino, G., Capria, A., Pinna, S., Onori, D., Porzi, C., Scaffardi, M., Malacarne, A., et al. (2014) · Nature · doi:10.1038/nature13078 · Cited by 1,111
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Research works printed but not linked: 11
- 10.1117/12.2228825 · doi:10.1117/12.2228825
- 10.1063/1.3290631 · doi:10.1063/1.3290631
- 10.1103/PhysRevB.92.174113 · doi:10.1103/physrevb.92.174113
- 10.1116/1.579036 · doi:10.1116/1.579036
- G. Kramer, 2004, Proceedings of the 18th European Frequency and Time Forum, Guildford, UK
- J. E. Gray, 1974, Proceedings of the 28th Annual Symposium on Frequency Control, 29-31 May 1974, Atlantic City, New Jersey, New Jersey
- 10.1364/JOSA.72.001258 · doi:10.1364/josa.72.001258
- 10.1109/PROC.1972.8696 · doi:10.1109/proc.1972.8696
- 10.1109/TIM.1981.6312409 · doi:10.1109/tim.1981.6312409
- D. W. Allan, 1981, Proceedings of the 35th Ann. Freq. Control Symposium
- J. L. Hall, 1992, Laser Manipulation of Atoms and Ions, Proceedings Internat. School of Physics Enrico Fermi, Vol. Course CXVIII
Cited by
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Atomic superheterodyne receiver based on microwave-dressed Rydberg spectroscopy
Jing, M., Hu, Y., Ma, J., Zhang, H., Zhang, L., Xiao, L., & Jia, S. (2020) · Nature Physics · doi:10.1038/s41567-020-0918-5 · Cited by 576
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Self-citation
Metadata
- Authors
- Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., & Sterr, U.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2017-06-28
- Volume
- 118
- Issue
- 26
- Pages
- 263202-263202
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2963808380
- Cited by
- 584
- References
- 46
- FWCI
- 26.84
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- Funders
- National Institute of Standards and Technology
- Horizon 2020 Framework Programme (15SIB03 OC18)
- Alexander von Humboldt-Stiftung
- U.S. Department of Defense
- Centre for Quantum Engineering and Space-Time Research (QUEST)
- Physikalisch-Technische Bundesanstalt (PTB)
- JILA Physics Frontier Center (NSF)
- EURAMET
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 1.5 μm Lasers with Sub-10 mHz Linewidth. https://app.cochat.ai/papers/10.1103/physrevlett.118.263202
- The paper
- Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., & Sterr, U. (2017). 1.5 μm Lasers with Sub-10 mHz Linewidth. Physical Review Letters. https://doi.org/10.1103/physrevlett.118.263202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.