The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Photoacoustic imaging in biomedicine
Open accessAbstract
Photoacoustic imaging (also called optoacoustic or thermoacoustic imaging) has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered media, scanning tomography with focused ultrasonic transducers, image forming with an acoustic lens, and computed tomography with unfocused transducers, are introduced. Special emphasis is placed on computed tomography, including reconstruction algorithms, spatial resolution, and related recent experiments. Promising biomedical applications are discussed throughout the text, including (1) tomographic imaging of the skin and other superficial organs by laser-induced photoacoustic microscopy, which offers the critical advantages, over current high-resolution optical imaging modalities, of deeper imaging depth and higher absorption contrasts, (2) breast cancer detection by near-infrared light or radio-frequency–wave-induced photoacoustic imaging, which has important potential for early detection, and (3) small animal imaging by laser-induced photoacoustic imaging, which measures unique optical absorption contrasts related to important biochemical information and provides better resolution in deep tissues than optical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Angiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Gold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
Carbon dots—Emerging light emitters for bioimaging, cancer therapy and optoelectronics
Hola, K., Zhang, Y., Wang, Y., Giannelis, E. P., Zboril, R., & Rogach, A. L. (2014) · Nano Today · doi:10.1016/j.nantod.2014.09.004 · Cited by 992
Golden carbon nanotubes as multimodal photoacoustic and photothermal high-contrast molecular agents
Kim, J.-W., Galanzha, E. I., Shashkov, E. V., Moon, H.-M., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.231 · Cited by 710
Molecular Motion in Aggregates: Manipulating TICT for Boosting Photothermal Theranostics
Liu, S., Zhou, X., Zhang, H., Ou, H., Lam, J. W. Y., Liu, Y., Shi, L., Ding, D., & Tang, B. Z. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b13889 · Cited by 647
Prospects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Self-citation
Metadata
- Authors
- Xu, M., & Wang, L. V.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-04-01
- Volume
- 77
- Issue
- 4
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2023074414
- Cited by
- 2,700
- References
- 4
- FWCI
- 52.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoacoustic imaging in biomedicine. https://app.cochat.ai/papers/10.1063/1.2195024
- The paper
- Xu, M., & Wang, L. V. (2006). Photoacoustic imaging in biomedicine. Review of Scientific Instruments. https://doi.org/10.1063/1.2195024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.