The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Magnetoencephalography with an atomic magnetometer
Abstract
The authors demonstrate detection and mapping of brain magnetic fields evoked by auditory stimulation with a noncryogenic magnetometer based on spin precession of potassium atoms in spin-exchange-relaxation-free regime. Optical readout using a photodiode array allows flexibility in detector placement while using common elements for most components of the multichannel system. Absence of a cryogenic dewar eliminates magnetic Johnson noise from radiation shields and allows the use of a compact magnetic shield with a high shielding factor. The magnetometer sensitivity is currently equal to 3.5fT∕Hz1∕2 at 10Hz, similar to superconducting quantum interference device magnetoencephalography systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationThe P300: Where in the Brain Is It Produced and What Does It Tell Us?
Linden, D. E. J. (2005) · The Neuroscientist · doi:10.1177/1073858405280524 · Cited by 833
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
Self-citationPrinciples of Operation of the Rubidium Vapor Magnetometer
Bloom, A. L. (1962) · Applied Optics · doi:10.1364/ao.1.000061 · Cited by 282
Mager, A. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066714 · Cited by 167
Magnetoencephalography - a noninvasive brain imaging method with 1 ms time resolution
Gratta, C. D., Pizzella, V., Tecchio, F., & Romani, G. L. (2001) · Reports on Progress in Physics · doi:10.1088/0034-4885/64/12/204 · Cited by 126
Temporal patterns of human cortical activity reflect tone sequence structure
Patel, A. D., & Balaban, E. (2000) · Nature · doi:10.1038/35003577 · Cited by 112
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationBoto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
Metadata
- Authors
- Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2006-11-20
- Volume
- 89
- Issue
- 21
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2011709895
- Cited by
- 441
- References
- 12
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetoencephalography with an atomic magnetometer. https://app.cochat.ai/papers/10.1063/1.2392722
- The paper
- Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006). Magnetoencephalography with an atomic magnetometer. Applied Physics Letters. https://doi.org/10.1063/1.2392722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.