Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record.

New experimental device for infrared spectral directional emissivity measurements in a controlled environment

del Campo, Leire, Pérez-Sáez, Raúl B., Esquisabel, Xabier, Fernández, Ignacio, Tello, Manuel J.·2006·Review of Scientific Instruments

Abstract

A new experimental device for infrared spectral directional emissivity measurements in a controlled atmosphere is presented. The sample holder, which permits to measure spectral directional emissivity up to 1050K, is placed inside a stainless steel sample chamber that can be evacuated or filled with different gases. The signal detection is carried out by means of a Fourier transform infrared spectrometer. The experimental results focus on the capability of the device to perform emissivity measurements as a function of temperature, emission angle, and in situ surface state evolution. A careful study of the sample temperature homogeneity and the measurement method has been done, including the background radiation, the apparatus response function, and temperature differences between the sample and the blackbody radiator. As a consequence, a compact expression for the sample emissivity that generalizes those previously obtained for the direct radiometric measurement method is found. The error assessment shows that the main contribution to the emissivity uncertainty is related to the sample temperature. The overall uncertainty at intermediate temperature is estimated to be around 3% at short wavelengths. Emissivity measurements of Armco iron were used in order to check the accuracy of the experimental device. The experimental results show an excellent fit with direct emissivity data accessible in the literature, as well as with the theoretical emissivity obtained from the Hagen-Rubens relation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2393157

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
del Campo, L., Pérez-Sáez, R. B., Esquisabel, X., Fernández, I., & Tello, M. J.
Venue
Review of Scientific Instruments
Published
2006-11-01
Volume
77
Issue
11
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2049123304
Cited by
198
References
0
FWCI
9.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New experimental device for infrared spectral directional emissivity measurements in a controlled environment. https://app.cochat.ai/papers/10.1063/1.2393157
The paper
del Campo, L., Pérez-Sáez, R. B., Esquisabel, X., Fernández, I., & Tello, M. J. (2006). New experimental device for infrared spectral directional emissivity measurements in a controlled environment. Review of Scientific Instruments. https://doi.org/10.1063/1.2393157

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.