Interface microstructure engineering by high power impulse magnetron sputtering for the enhancement of adhesion

Ehiasarian, A. P., Wen, J. G., Petrov, I.·2007·Journal of Applied Physics

Abstract

An excellent adhesion of hard coatings to steel substrates is paramount in practically all application areas. Conventional methods utilize Ar glow etching or cathodic arc discharge pretreatments that have the disadvantage of producing weak interfaces or adding droplets, respectively. One tool for interface engineering is high power impulse magnetron sputtering (HIPIMS). HIPIMS is based on conventional sputtering with extremely high peak power densities reaching 3kWcm−2 at current densities of >2Acm−2. HIPIMS of Cr and Nb was used to prepare interfaces on 304 stainless steel and M2 high speed steel (HSS). During the pretreatment, the substrates were biased to Ubias=−600V and Ubias=−1000V in the environment of a HIPIMS of Cr and Nb plasma. The bombarding flux density reached peak values of 300mAcm−2 and consisted of highly ionized metal plasma containing a high proportion of Cr1+ and Nb1+. Pretreatments were also carried out with Ar glow discharge and filtered cathodic arc as comparison. The adhesion was evaluated for coatings consisting of a 0.3μm thick CrN base layer and a 4μm thick nanolayer stack of CrN∕NbN with a period of 3.4nm, hardness of HK0.025=3100, and residual stress of −1.8GPa. For HIPIMS of Cr pretreatment, the adhesion values on M2 HSS reached scratch test critical load values of LC=70N, thus comparing well to LC=51N for interfaces pretreated by arc discharge plasmas and to LC=25N for Ar etching. Cross sectional transmission electron microscopy studies revealed a clean interface and large areas of epitaxial growth in the case of HIPIMS pretreatment. The HIPIMS pretreatment promoted strong registry between the orientation of the coating and polycrystalline substrate grains due to the incorporation of metal ions and the preservation of crystallinity of the substrate. Evidence and conditions for the formation of cube-on-cube epitaxy and axiotaxy on steel and γ-TiAl substrates are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2697052

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 299

Metadata

Authors
Ehiasarian, A. P., Wen, J. G., & Petrov, I.
Venue
Journal of Applied Physics
Published
2007-03-01
Volume
101
Issue
5
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2107274894
Cited by
299
References
0
FWCI
30.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interface microstructure engineering by high power impulse magnetron sputtering for the enhancement of adhesion. https://app.cochat.ai/papers/10.1063/1.2697052
The paper
Ehiasarian, A. P., Wen, J. G., & Petrov, I. (2007). Interface microstructure engineering by high power impulse magnetron sputtering for the enhancement of adhesion. Journal of Applied Physics. https://doi.org/10.1063/1.2697052

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.