The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system
Abstract
The feasibility for in vivo navigation of untethered devices or robots is demonstrated with the control and tracking of a 1.5mm diameter ferromagnetic bead in the carotid artery of a living swine using a clinical magnetic resonance imaging (MRI) platform. Navigation is achieved by inducing displacement forces from the three orthogonal slice selection and signal encoding gradient coils of a standard MRI system. The proposed method performs automatic tracking, propulsion, and computer control sequences at a sufficient rate to allow navigation along preplanned paths in the blood circulatory system. This technique expands the range of applications in MRI-based interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
White, F. M. (1974) · Cited by 5,899
Functionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
On optimum design in fluid mechanics
Pironneau, O. (1974) · Journal of Fluid Mechanics · doi:10.1017/s0022112074002023 · Cited by 691
On optimum profiles in Stokes flow
Pironneau, O. (1973) · Journal of Fluid Mechanics · doi:10.1017/s002211207300145x · Cited by 437
Mathieu, J.-B., Beaudoin, G., & Martel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862570 · Cited by 248
Self-citationContact and friction between catheter and blood vessel
TAKASHIMA, K., Shimomura, R., Kitou, T., Terada, H., Yoshinaka, K., & IKEUCHI, K. (2006) · Tribology International · doi:10.1016/j.triboint.2005.10.010 · Cited by 134
Lund, E. G., Møller, H., & Jakobsen, L. A. (2003) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-003-0288-5 · Cited by 62
Cited by
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Magneto-aerotactic bacteria deliver drug-containing nanoliposomes to tumour hypoxic regions
Felfoul, O., Mohammadi, M., Taherkhani, S., de Lanauze, D., Zhong Xu, Y., Loghin, D., Essa, S., Jancik, S., Houle, D., Lafleur, M., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.137 · Cited by 1,106
Self-citationBiomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Metadata
- Authors
- Martel, S., Mathieu, J.-B., Felfoul, O., Chanu, A., Aboussouan, E., Tamaz, S., Pouponneau, P., Yahia, L., Beaudoin, G., Soulez, G., & Mankiewicz, M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2007-03-12
- Volume
- 90
- Issue
- 11
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2037424018
- Cited by
- 361
- References
- 7
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.