10 mJ class femtosecond optical parametric amplifier for generating soft x-ray harmonics
Abstract
Power scaling of an infrared (IR) parametric amplifier chain, pumped at 800nm by a terawatt Ti:sapphire laser system has been reported. A total output energy exceeding 10mJ with 40fs pulse duration has been achieved in the IR region, which is the highest energy and peak power ever reported for an ultrafast optical parametric amplifier scheme. By applying the developed IR pulses to high-order harmonic generation, we have observed a significant cutoff extension compared to the case of 800nm driving wavelength. This source suits as a driver laser for extending high-order harmonic photon energy into the kiloelectronvolts region.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
High-harmonic sources extended to soft x-ray domain are in principle capable of achieving attosecond durations and provide pulses perfectly synchronized with driving laser pulse.
“High-harmonic sources, which are being extended to the soft x-ray domain [129, 202, 203], are in principle clearly capable of achieving attosecond durations and provide pulses that are perfectly synchronized with the driving laser pulse.”
From Roadmap of ultrafast x-ray atomic and molecular physics (2018) · cites this paper as [202]
Cites
Plasma perspective on strong field multiphoton ionization
Corkum, P. B. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.1994 · Cited by 7,217 · see citing works
Hentschel, M., Kienberger, R., Spielmann, C., Reider, G. A., Milosevic, N., Brabec, T., Corkum, P., Heinzmann, U., Drescher, M., & Krausz, F. (2001) · Nature · doi:10.1038/35107000 · Cited by 2,884 · see citing works
Isolated Single-Cycle Attosecond Pulses
Sansone, G., Benedetti, E., Calegari, F., Vozzi, C., Avaldi, L., Flammini, R., Poletto, L., Villoresi, P., Altucci, C., Velotta, R., et al. (2006) · Science · doi:10.1126/science.1132838 · Cited by 1,706 · see citing works
Optimizing High Harmonic Generation in Absorbing Gases: Model and Experiment
Constant, E., Garzella, D., Breger, P., Mével, E., Dorrer, C., Leblanc, C., Salin, F., & Agostini, P. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.1668 · Cited by 650 · see citing works
Scaling of Wave-Packet Dynamics in an Intense Midinfrared Field
Tate, J., Auguste, T., Muller, H. G., Salieres, P. L., Agostini, P., & DiMauro, L. F. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.013901 · Cited by 611 · see citing works
Scaling strong-field interactions towards the classical limit
Colosimo, P., Doumy, G., Blaga, C. I., Wheeler, J. A., Hauri, C. P., Catoire, F., Tate, J., Chirla, R., March, A. M., Paulus, G. G., et al. (2008) · Nature Physics · doi:10.1038/nphys914 · Cited by 410 · see citing works
Direct observation of attosecond light bunching
Tzallas, P., Charalambidis, D., Papadogiannis, N. A., Witte, K. J., & Tsakiris, G. D. (2003) · Nature · doi:10.1038/nature02091 · Cited by 391 · see citing works
Nonlinear optics in the extreme ultraviolet
Sekikawa, T., Kosuge, A., Kanai, T., & Watanabe, S. (2004) · Nature · doi:10.1038/nature03108 · Cited by 363 · see citing works
Self-citationNabekawa, Y., Hasegawa, H., Takahashi, E. J., & Midorikawa, K. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.043001 · Cited by 262 · see citing works
Self-citationPrecision measurements of the total photoionization cross-sections of He, Ne, Ar, Kr, and Xe
Samson, J. A. R., & Stolte, W. C. (2002) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/s0368-2048(02)00026-9 · Cited by 243 · see citing works
Generation of highly coherent submicrojoule soft x rays by high-order harmonics
Takahashi, E. J., Nabekawa, Y., Otsuka, T., Obara, M., & Midorikawa, K. (2002) · Physical Review A · doi:10.1103/physreva.66.021802 · Cited by 234 · see citing works
Self-citationGeneration of 10-µJ coherent extreme-ultraviolet light by use of high-order harmonics
Takahashi, E. J., Nabekawa, Y., & Midorikawa, K. (2002) · Optics Letters · doi:10.1364/ol.27.001920 · Cited by 227 · see citing works
Self-citationMillijoule-level phase-stabilized few-optical-cycle infrared parametric source
Vozzi, C., Calegari, F., Benedetti, E., Gasilov, S. V., Sansone, G., Cerullo, G., Nisoli, M., Silvestri, S. D., & Stagira, S. (2007) · Optics Letters · doi:10.1364/ol.32.002957 · Cited by 202 · see citing works
Parametric amplification of few-cycle carrier-envelope phase-stable pulses at 21 μm
Fuji, T., Ishii, N., Teisset, C. Y., Gu, X., Metzger, T., Baltuška, A., Forget, N., Kaplan, D., Galvanauskas, A., & Krausz, F. (2006) · Optics Letters · doi:10.1364/ol.31.001103 · Cited by 184 · see citing works
Enhanced phase-matching for generation of soft X-ray harmonics and attosecond pulses in atomic gases
Yakovlev, V. S., Ivanov, M., & Krausz, F. (2007) · Optics Express · doi:10.1364/oe.15.015351 · Cited by 162 · see citing works
Nabekawa, Y., Shimizu, T., Okino, T., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.083901 · Cited by 136 · see citing works
Self-citationIntense self-compressed, self-phase-stabilized few-cycle pulses at 2 μm from an optical filament
Hauri, C. P., López-Martens, R., Blaga, C. I., Schultz, K. D., Cryan, J. P., Chirla, R., Colosimo, P., Doumy, G., March, A. M., Roedig, C., et al. (2007) · Optics Letters · doi:10.1364/ol.32.000868 · Cited by 122 · see citing works
Highly efficient parametric conversion of femtosecond Ti:sapphire laser pulses at 1 kHz
Nisoli, M., Danielius, R. V., Piskarskas, A., et al. (1994) · Optics Letters · doi:10.1364/ol.19.001973 · Cited by 100 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Roadmap of ultrafast x-ray atomic and molecular physics
Young, L., Ueda, K., Gühr, M., Bucksbaum, P. H., Simon, M., Mukamel, S., Rohringer, N., Prince, K. C., Masciovecchio, C., Meyer, M., et al. (2018) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/aa9735 · Cited by 337 · see citing works
Dual-chirped optical parametric amplification for generating few hundred mJ infrared pulses
Zhang, Q., Takahashi, E. J., Mücke, O. D., Lu, P., & Midorikawa, K. (2011) · Optics Express · doi:10.1364/oe.19.007190 · Cited by 90 · see citing works
Self-citation10 mJ 5-cycle pulses at 1.8 <i>μ</i>m through optical parametric amplification
Thiré, N., Beaulieu, S., Cardin, V., Laramée, A., Wanie, V., Schmidt, B. E., & Légaré, F. (2015) · Applied Physics Letters · doi:10.1063/1.4914344 · Cited by 56 · see citing works
- Authors
- Takahashi, E. J., Kanai, T., Nabekawa, Y., & Midorikawa, K.
- Affiliations
- RIKEN (JP)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2008-07-28
- Volume
- 93
- Issue
- 4
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1982547918
- Cited by
- 99
- References
- 18
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 1 · 2020: 5 · 2018: 6 · 2017: 8 · 2016: 3 · 2015: 7 · 2014: 6 · 2013: 4 · 2012: 8
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic Crystal and Fiber Optics
- Physical Sciences › Engineering › Computational Mechanics › Laser Material Processing Techniques
- Keywords
- high harmonic generation, power scaling, Ti:sapphire laser pumping, ultrafast lasers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review