The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultralow noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
Open accessAbstract
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultrastable optical cavity to generate a low-noise microwave reference signal. Comparison with both a cryogenic sapphire oscillator (CSO) and a titanium-sapphire-based optical frequency comb system exhibit a stability of about 3×10−15 between 1 and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art cesium fountain clock. The resulting clock is compared to the CSO and exhibits a stability of 3.5×10−14τ−1/2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Santarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
Self-citationSearch for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citation
Cited by
Generation of ultrastable microwaves via optical frequency division
Fortier, T. M., Kirchner, M. S., Quinlan, F., Taylor, J., Bergquist, J. C., Rosenband, T., Lemke, N., Ludlow, A., Jiang, Y., Oates, C. W., et al. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.121 · Cited by 887
Photonic microwave signals with zeptosecond-level absolute timing noise
Xie, X., Bouchand, R., Nicolodi, D., Giunta, M., Hänsel, W., Lezius, M., Joshi, A., Datta, S., Alexandre, C., Lours, M., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.215 · Cited by 441
Self-citationProgress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Self-citationSpectral purity transfer between optical wavelengths at the 10−18 level
Nicolodi, D., Argence, B., Zhang, W., Le Targat, R., Santarelli, G., & Le Coq, Y. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.361 · Cited by 132
Self-citation
Metadata
- Authors
- Millo, J., Abgrall, M., Lours, M., English, E. M. L., Jiang, H., Guéna, J., Clairon, A., Tobar, M. E., Bize, S., Le Coq, Y., & Santarelli, G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2009-04-06
- Volume
- 94
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2035111818
- Cited by
- 179
- References
- 2
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultralow noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock. https://app.cochat.ai/papers/10.1063/1.3112574
- The paper
- Millo, J., Abgrall, M., Lours, M., English, E. M. L., Jiang, H., Guéna, J., Clairon, A., Tobar, M. E., Bize, S., Le Coq, Y., & Santarelli, G. (2009). Ultralow noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock. Applied Physics Letters. https://doi.org/10.1063/1.3112574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.