Cited by 29Spacecraft and Cryogenic TechnologiesSuperconducting Materials and ApplicationsAerogels and thermal insulation

GLASS BUBBLES INSULATION FOR LIQUID HYDROGEN STORAGE TANKS

Open access
Sass, J. P., Cyr, W. W. St., Barrett, T. M., Baumgartner, R. G., Lott, J. W., Fesmire, J. E., Weisend, J. G.·2010·AIP Conference Proceedings

Abstract

cryogenic thermal insulation system

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.3422430

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The evacuated glass bubbles insulation system reduces LH2 boiloff by 46% versus perlite in field demonstrations.

    “The evacuated glass bubbles insulation system is based on the prior two decades of research to prove the thermal performance benefits as well as the mechanical and vacuum integrity; and has been shown to reduce LH2 boiloff by 46% versus perlite in field demonstrations.”

    From Energy efficient large-scale storage of liquid hydrogen (2022) · cites this paper as [21]

    The Performance Testing and Conclusion sections report a 44% reduction in liquid-hydrogen boiloff versus perlite in the full-scale field application, not 46%. The Introduction assigns the 46% figure to liquid-nitrogen boiloff in earlier 1000 L tank testing. (LLM, conf=0.90)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • Only very limited liquid hydrogen performance and transfer data at 20 K is available.

    “However, even with thousands of analyses in LN2, when addressing LH2 performance and transfer data at 20 K, only very limited data is available.”

    From Simulation test platform for the controlled storage and transfer of liquid hydrogen (2024) · cites this paper as [11]

    The Introduction (page not provided) describes a gap between small-scale liquid-hydrogen insulation tests and the much larger tanks planned for future use. That supports a narrower shortage of large-scale performance data, but the paper does not establish that liquid-hydrogen performance and transfer data at 20 K are generally very limited. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 6

  1. e Insula Advances in Cryogenic Engineering 49A, edited by Joseph Waynert et al., American Institute of Physics, New York, 2004, pp. 619-626.
  2. Testing of Glass Microspheres Under Cryogenic- Advances in Cryogenic Engineering 49A, edited by Joseph Waynert et al., American Institute of Physics, New York, 2004, pp. 612-618.
  3. Fesmire, J.E., Sass, J.P., Nagy, Z.F., Sojourner, S.J., Morris, D.L., and Augustynowicz, S.D. - Efficient Storage of C Advances in Cryogenic Engineering 53B, edited by J. G. Weisend et al., American Institute of Physics, New York, 2008, pp. 1383-1391.
  4. Sass, J.P., Fesmire, J.E., Nagy, Z.F., Sojourner, S.J., Morris, D.L. and Augusty Performance Comparison of Glass Microsphere and Perlite Insulation Systems for Liquid Hydrogen Storage T Advances in Cryogenic Engineering 53B, edited by J. G. Weisend et al., American Institute of Physics, New York, 2008, pp. 1375-1382.
  5. Modeling of Propellant Boiloff in a Cryogenic Storage T Advances in Cryogenic Engineering 53B, edited by J. G. Weisend et al., American Institute of Physics, New York, 2008, pp. 1507-1514.
  6. Baumgartner, R.G., Myers, E.A., Fesmire, J.E., Morris, D.L., Sok Microsphere Insulation in Cryogenic V Advances in Cryogenic Engineering 51B, edited by J. G. Weisend et al., American Institute of Physics, New York, 2006, pp. 1351-1358.

Cited by

Sorted by citations

Authors
Sass, J. P., Cyr, W. W. S., Barrett, T. M., Baumgartner, R. G., Lott, J. W., Fesmire, J. E., & Weisend, J. G.
Affiliations
  • Kennedy Space Center (US)
  • 3M (United States) (US)
  • Technology Applications (United States) (US)
  • Stennis Space Center (US)
Venue
AIP Conference Proceedings
Publisher
AIP
Published
2010
Pages
772-779
ISSN
0094-243X (ISSN-L)
OpenAlex
W1979179218
Cited by
29
References
0
Citations by year
2026: 4 · 2025: 8 · 2024: 5 · 2023: 3 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 1 · 2014: 2 · 2013: 1
FWCI
1.27
Type
conference paper
Language
en
Open access
Locations
  • AIP conference proceedings (publishedVersion)
  • NASA STI Repository (National Aeronautics and Space Administration) (submittedVersion)
Funders
  • National Aeronautics and Space Administration
  • Stennis Space Center
  • NASA Headquarters
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Superconducting Materials and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Aerogels and thermal insulation
Keywords
hollow glass microspheres, cryogenic insulation, liquid hydrogen storage, hydrogen storage tanks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review