The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Flexible room-temperature NO2 gas sensors based on carbon nanotubes/reduced graphene hybrid films
Abstract
We present a flexible room temperature NO2 gas sensor consisting of vertical carbon nanotubes (CNTs)/reduced graphene hybrid film supported by a polyimide substrate. The reduced graphene film alone showed a negligible sensor response, exhibiting abnormal N–P transitions during the initial NO2 injection. A hybrid film, formed by the growth of a vertically aligned CNT array (with CNTs 20 μm in length) on the reduced graphene film surface, exhibited remarkably enhanced sensitivities with weak N–P transitions. The increase in sensitivity was mainly attributed to the high sensitivity of the CNT arrays. The outstanding flexibility of the reduced graphene films ensured stable sensing performances in devices submitted to extreme bending stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Large-scale pattern growth of graphene films for stretchable transparent electrodes
Kim, K. S., Zhao, Y., Jang, H., Lee, S. Y., Kim, J. M., Kim, K. S., Ahn, J.-H., Kim, P., Choi, J.-Y., & Hong, B. H. (2009) · Nature · doi:10.1038/nature07719 · Cited by 10,452
Self-citationDetection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Electronic Transport Properties of Individual Chemically Reduced Graphene Oxide Sheets
Gómez-Navarro, C., Weitz, R. T., Bittner, A. M., Scolari, M., Mews, A., Burghard, M., & Kern, K. (2007) · Nano Letters · doi:10.1021/nl072090c · Cited by 2,389
Practical Chemical Sensors from Chemically Derived Graphene
Fowler, J. D., Allen, M. J., Tung, V. C., Yang, Y., Kaner, R. B., & Weiller, B. H. (2009) · ACS Nano · doi:10.1021/nn800593m · Cited by 1,447
Synthesis and Solid-State NMR Structural Characterization of 13 C-Labeled Graphite Oxide
Cai, W., Piner, R. D., Stadermann, F. J., Park, S., Shaibat, M. A., Ishii, Y., Yang, D., Velamakanni, A., An, S. J., Stoller, M., et al. (2008) · Science · doi:10.1126/science.1162369 · Cited by 1,184
Reduced graphene oxide for room-temperature gas sensors
Lu, G., Ocola, L. E., & Chen, J. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/44/445502 · Cited by 775
Identification of Electron Donor States in N-Doped Carbon Nanotubes
Czerw, R., Terrones, M., Charlier, J.-C., Blase, X., Foley, B., Kamalakaran, R., Grobert, N., Terrones, H., Tekleab, D., Ajayan, P. M., et al. (2001) · Nano Letters · doi:10.1021/nl015549q · Cited by 760
Mechanics of rollable and foldable film-on-foil electronics
Suo, Z., Ma, E. Y., Gleskova, H., & Wagner, S. (1999) · Applied Physics Letters · doi:10.1063/1.123478 · Cited by 711
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Functional Composite Materials Based on Chemically Converted Graphene
Bai, H., Li, C., & Shi, G. (2011) · Advanced Materials · doi:10.1002/adma.201003753 · Cited by 1,080
Yuan, W., & Shi, G. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta11774j · Cited by 1,073
Recent advances in graphene based gas sensors
Varghese, S. S., Lonkar, S., Singh, K. K., Swaminathan, S., & Abdala, A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.04.062 · Cited by 890
Two‐Dimensional Nanostructured Materials for Gas Sensing
Liu, X., Ma, T., Pinna, N., & Zhang, J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702168 · Cited by 851
Flexible Graphene-Based Wearable Gas and Chemical Sensors
Singh, E., Meyyappan, M., & Nalwa, H. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07063 · Cited by 776
Chemical sensing with 2D materials
Anichini, C., Czepa, W., Pakulski, D., Aliprandi, A., Ciesielski, A., & Samorì, P. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00417j · Cited by 756
Graphene–inorganic nanocomposites
Bai, S., & Shen, X. (2012) · RSC Adv. · doi:10.1039/c1ra00260k · Cited by 602
High‐Performance NO2 Sensors Based on Chemically Modified Graphene
Yuan, W., Liu, A., Huang, L., Li, C., & Shi, G. (2013) · Advanced Materials · doi:10.1002/adma.201203172 · Cited by 453
Superior Chemical Sensing Performance of Black Phosphorus: Comparison with MoS2 and Graphene
Cho, S., Lee, Y., Koh, H., Jung, H., Kim, J., Yoo, H., Kim, J., & Jung, H. (2016) · Advanced Materials · doi:10.1002/adma.201601167 · Cited by 431
Self-citationReview—Recent Advances in Carbon Nanomaterials as Electrochemical Biosensors
Kour, R., Arya, S., Young, S.-J., Gupta, V., Bandhoria, P., & Khosla, A. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6bc4 · Cited by 424
Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Li, W., Geng, X., Guo, Y., Rong, J., Gong, Y., Wu, L., Zhang, X., Li, P., Xu, J., Cheng, G., et al. (2011) · ACS Nano · doi:10.1021/nn201433r · Cited by 394
Dai, J., Ogbeide, O., Macadam, N., Sun, Q., Yu, W., Li, Y., Su, B.-L., Hasan, T., Huang, X., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00459a · Cited by 378
Two-dimensional layered nanomaterials for gas-sensing applications
Yang, W., Gan, L., Li, H., & Zhai, T. (2016) · Inorganic Chemistry Frontiers · doi:10.1039/c5qi00251f · Cited by 376
Li, S., Luo, Y., Lv, W., Yu, W., Wu, S., Hou, P., Yang, Q., Meng, Q., Liu, C., & Cheng, H. (2011) · Advanced Energy Materials · doi:10.1002/aenm.201100001 · Cited by 336
Self-Activated Transparent All-Graphene Gas Sensor with Endurance to Humidity and Mechanical Bending
Kim, Y. H., Kim, S. J., Kim, Y.-J., Shim, Y.-S., Kim, S. Y., Hong, B. H., & Jang, H. W. (2015) · ACS Nano · doi:10.1021/acsnano.5b04680 · Cited by 332
Self-citationSteam Etched Porous Graphene Oxide Network for Chemical Sensing
Han, T. H., Huang, Y.-K., Tan, A. T. L., Dravid, V. P., & Huang, J. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205693t · Cited by 318
Recent advances in carbon material-based NO2 gas sensors
Lee, S. W., Lee, W., Hong, Y., Lee, G., & Yoon, D. S. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.08.203 · Cited by 304
Self-citationTuning gas-sensing properties of reduced graphene oxide using tin oxide nanocrystals
Mao, S., Cui, S., Lu, G., Yu, K., Wen, Z., & Chen, J. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm30378g · Cited by 284
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Graphene Nanomesh As Highly Sensitive Chemiresistor Gas Sensor
Paul, R. K., Badhulika, S., Saucedo, N. M., & Mulchandani, A. (2012) · Analytical Chemistry · doi:10.1021/ac3012895 · Cited by 262
A review on flexible gas sensors: From materials to devices
Alrammouz, R., Podlecki, J., Abboud, P., Sorli, B., & Habchi, R. (2018) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2018.10.036 · Cited by 255
Wu, J., Wu, Z., Han, S., Yang, B.-R., Gui, X., Tao, K., Liu, C., Miao, J., & Norford, L. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17437 · Cited by 225
Hydrogen gas sensor based on metal oxide nanoparticles decorated graphene transistor
Zhang, Z., Zou, X., Xu, L., Liao, L., Liu, W., Ho, J., Xiao, X., Jiang, C., & Li, J. (2015) · Nanoscale · doi:10.1039/c5nr01924a · Cited by 212
Metadata
- Authors
- Jeong, H. Y., Lee, D.-S., Choi, H. K., Lee, D. H., Kim, J.-E., Lee, J. Y., Lee, W. J., Kim, S. O., & Choi, S.-Y.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-05-24
- Volume
- 96
- Issue
- 21
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2088861830
- Cited by
- 285
- References
- 13
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.