Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 624

The DOI matches its Crossref record.

Magnetic force microscopy: General principles and application to longitudinal recording media

Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., Yogi, T.·1990·Journal of Applied Physics

Abstract

This paper discusses the principles of magnetic force microscopy (MFM) and its application to magnetic recording studies. We use the ac detection method which senses the force gradient acting on a small magnetic tip due to fields emanating from the domain structure in the sample. Tip fabrication procedures are described for two types of magnetic tips: etched tungsten wires with a sputter-deposited magnetic coating and etched nickel wires. The etched nickel wires are shown to have an apex radius on the order of 30 nm and a taper half-angle of approximately 3°. Lorentz-mode transmission electron microscopy of the nickel tips reveals that the final 20 μm is essentially single domain with magnetization approximately parallel with the tip axis. Images of written bit transitions are presented for several types of magnetic media, including CoPtCr, CoSm, and CoCr thin films, as well as γ-Fe2O3 particulate media. In general, the written magnetization patterns are seen with high contrast and with resolution better than 100 nm. A number of magnetic recording applications are discussed, including the investigation of overwrite behavior and the writing characteristics in CoSm media at high data density. Computer calculations were performed to simulate the MFM response to written magnetic transitions. By including the extended geometry of the tip, the nonparallel orientation of the cantilever, and the finite width of the magnetic transitions, good agreement with experiment was obtained. The model calculations correctly predict the experimentally observed change in image contrast that occurs as a function of tip orientation. Computer calculations showing the dependence of resolution on tip geometry are also presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.346713

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 624

Metadata

Authors
Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T.
Venue
Journal of Applied Physics
Published
1990-08-01
Volume
68
Issue
3
Pages
1169-1183
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2037775721
Cited by
624
References
0
FWCI
17.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic force microscopy: General principles and application to longitudinal recording media. https://app.cochat.ai/papers/10.1063/1.346713
The paper
Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T. (1990). Magnetic force microscopy: General principles and application to longitudinal recording media. Journal of Applied Physics. https://doi.org/10.1063/1.346713

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.