The DOI matches its Crossref record.
Magnetic force microscopy: General principles and application to longitudinal recording media
Abstract
This paper discusses the principles of magnetic force microscopy (MFM) and its application to magnetic recording studies. We use the ac detection method which senses the force gradient acting on a small magnetic tip due to fields emanating from the domain structure in the sample. Tip fabrication procedures are described for two types of magnetic tips: etched tungsten wires with a sputter-deposited magnetic coating and etched nickel wires. The etched nickel wires are shown to have an apex radius on the order of 30 nm and a taper half-angle of approximately 3°. Lorentz-mode transmission electron microscopy of the nickel tips reveals that the final 20 μm is essentially single domain with magnetization approximately parallel with the tip axis. Images of written bit transitions are presented for several types of magnetic media, including CoPtCr, CoSm, and CoCr thin films, as well as γ-Fe2O3 particulate media. In general, the written magnetization patterns are seen with high contrast and with resolution better than 100 nm. A number of magnetic recording applications are discussed, including the investigation of overwrite behavior and the writing characteristics in CoSm media at high data density. Computer calculations were performed to simulate the MFM response to written magnetic transitions. By including the extended geometry of the tip, the nonparallel orientation of the cantilever, and the finite width of the magnetic transitions, good agreement with experiment was obtained. The model calculations correctly predict the experimentally observed change in image contrast that occurs as a function of tip orientation. Computer calculations showing the dependence of resolution on tip geometry are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Haynes, C. L., & Van Duyne, R. P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp010657m · Cited by 2,500
Mechanical detection of magnetic resonance
Rugar, D., Yannoni, C. S., & Sidles, J. A. (1992) · Nature · doi:10.1038/360563a0 · Cited by 395
Self-citationObservation of single charge carriers by force microscopy
Schönenberger, C., & Alvarado, S. F. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.3162 · Cited by 267
Regulation of a microcantilever response by force feedback
Mertz, J., Marti, O., & Mlynek, J. (1993) · Applied Physics Letters · doi:10.1063/1.109413 · Cited by 265
First images from a magnetic resonance force microscope
Züger, O., & Rugar, D. (1993) · Applied Physics Letters · doi:10.1063/1.110460 · Cited by 97
Self-citation
Metadata
- Authors
- Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1990-08-01
- Volume
- 68
- Issue
- 3
- Pages
- 1169-1183
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2037775721
- Cited by
- 624
- References
- 0
- FWCI
- 17.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic force microscopy: General principles and application to longitudinal recording media. https://app.cochat.ai/papers/10.1063/1.346713
- The paper
- Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T. (1990). Magnetic force microscopy: General principles and application to longitudinal recording media. Journal of Applied Physics. https://doi.org/10.1063/1.346713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.