A transmission electron microscopy study of low-temperature reaction at the Co-Si interface
The DOI matches its Crossref record.
Abstract
An efficient preparation method, which provides wedge-shaped cross-section transmission electron microscopy samples, has been developed. It was then used to investigate the structure of as-deposited cobalt multilayers on silicon substrates by rf plasma sputtering. It was found that an extended reaction takes place between Co and Si probably during the deposition. The cobalt atoms react with the silicon substrate to form an amorphous silicide layer. When the deposited layer is <3 nm thick, it entirely reacts with the substrate and can form an amorphous silicide as large as 5 nm. Above 4–5 nm thickness, growth of Co crystallites comes in competition with the formation of the amorphous silicide and limits it to 2 nm. The composition of this amorphous silicide is estimated to be Co2Si. In Co/C multilayers, the reactivity between the two materials is negligible, and the coalescence thickness of cobalt is 2–3 nm. At 2 nm, the cobalt layers are noncontinuous and very rough, whereas at 3 nm the critical thickness for crystalline nuclei coalescence has already been reached. The cobalt layers are then polycrystalline and have a reasonable roughness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
TENDON INJURY AND TENDINOPATHY: HEALING AND REPAIR
SHARMA, P., & MAFFULLI, N. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00030 · Cited by 1,074
Sarcopenia: etiology, clinical consequences, intervention, and assessment
Lang, T., Streeper, T., Cawthon, P., Baldwin, K., Taaffe, D. R., & Harris, T. B. (2010) · Osteoporosis International · doi:10.1007/s00198-009-1059-y · Cited by 777
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Achilles Tendon Injuries in Athletes
Kvist, M. (1994) · Sports Medicine · doi:10.2165/00007256-199418030-00004 · Cited by 571
Metadata
- Authors
- Ruterana, P., Houdy, P., & Boher, P.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1990-08-01
- Volume
- 68
- Issue
- 3
- Pages
- 1033-1037
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1963568539
- Cited by
- 144
- References
- 0
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A transmission electron microscopy study of low-temperature reaction at the Co-Si interface. https://app.cochat.ai/papers/10.1063/1.346741
- The paper
- Ruterana, P., Houdy, P., & Boher, P. (1990). A transmission electron microscopy study of low-temperature reaction at the Co-Si interface. Journal of Applied Physics. https://doi.org/10.1063/1.346741
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.