Nanowire superconducting single-photon detectors on GaAs for integrated quantum photonic applications
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We demonstrate efficient nanowire superconducting single photon detectors (SSPDs) based on NbN thin films grown on GaAs. NbN films ranging from 3 to 5 nm in thickness have been deposited by dc magnetron sputtering on GaAs substrates at 350 °C. These films show superconducting properties comparable to similar films grown on sapphire and MgO. In order to demonstrate the potential for monolithic integration, SSPDs were fabricated and measured on GaAs/AlAs Bragg mirrors, showing a clear cavity enhancement, with a peak quantum efficiency of 18.3% at λ=1300 nm and T=4.2 K.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A scheme for efficient quantum computation with linear optics
Knill, E., Laflamme, R., & Milburn, G. J. (2001) · Nature · doi:10.1038/35051009 · Cited by 5,880
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Semiconductor quantum light sources
Shields, A. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.46 · Cited by 900
Optical Quantum Computation Using Cluster States
Nielsen, M. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.040503 · Cited by 614
Cited by
Detecting single infrared photons with 93% system efficiency
Marsili, F., Verma, V. B., Stern, J. A., Harrington, S., Lita, A. E., Gerrits, T., Vayshenker, I., Baek, B., Shaw, M. D., Mirin, R. P., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.13 · Cited by 1,202
Self-citationSuperconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Superconducting nanowire single-photon detectors with 98% system detection efficiency at 1550 nm
Reddy, D. V., Nerem, R. R., Nam, S. W., Mirin, R. P., & Verma, V. B. (2020) · Optica · doi:10.1364/optica.400751 · Cited by 403
Waveguide superconducting single-photon detectors for integrated quantum photonic circuits
Sprengers, J. P., Gaggero, A., Sahin, D., Jahanmirinejad, S., Frucci, G., Mattioli, F., Leoni, R., Beetz, J., Lermer, M., Kamp, M., et al. (2011) · Applied Physics Letters · doi:10.1063/1.3657518 · Cited by 285
Self-citationDietrich, C. P., Fiore, A., Thompson, M. G., Kamp, M., & Höfling, S. (2016) · Laser & Photonics Reviews · doi:10.1002/lpor.201500321 · Cited by 266
Self-citation
Metadata
- Authors
- Gaggero, A., Nejad, S. J., Marsili, F., Mattioli, F., Leoni, R., Bitauld, D., Sahin, D., Hamhuis, G. J., Nötzel, R., Sanjines, R., & Fiore, A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-10-11
- Volume
- 97
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2014861611
- Cited by
- 76
- References
- 4
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.