Thickness and sound velocity measurement in thin transparent films with laser picosecond acoustics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new thin-film optical testing method is described for both thickness and sound velocity of transparent films on opaque substrates with laser picosecond acoustics using the optical pump-probe technique. The theory of excitation and detection of ultrasonic stress pulses for this geometry is presented in detail together with experimental results for sputtered thin films of silica of thickness 200 nm–2 μm on amorphous germanium substrates. Reflectance variations, measured as a function of pump-probe delay time, are characterized by echoes and beating oscillations superimposed on periodic steplike changes. These effects are modeled as a sum of an echo contribution from the stress-induced modulation of the substrate reflectance, an interference contribution from the light reflected by the moving stress pulse in the transparent film, a contribution from the modulation of the light on transmission through this stress pulse, and a contribution from the stress-induced ultrafast vibrations of the film interfaces of order 10−3 nm. The latter contribution arises from thin-film interference effects that represent a novel detection mechanism for surface vibrations in the picosecond regime. Sound velocity and thickness are derived from the data to an accuracy of a few percent, and the photoelastic constant of the transparent film is determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coherent Phonon Generation and Detection by Picosecond Light Pulses
Thomsen, C., Strait, J., Vardeny, Z., Maris, H. J., Tauc, J., & Hauser, J. J. (1984) · Physical Review Letters · doi:10.1103/physrevlett.53.989 · Cited by 581
Cited by
Fundamentals of picosecond laser ultrasonics
Matsuda, O., Larciprete, M. C., Li Voti, R., & Wright, O. B. (2015) · Ultrasonics · doi:10.1016/j.ultras.2014.06.005 · Cited by 283
Self-citationCoherent Phonon Detection From Ultrafast Surface Vibrations
Wright, O. B., & Kawashima, K. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.1668 · Cited by 180
Self-citationCharacterization of nanostructured metal films by picosecond acoustics and interferometry
O’Hara, K. E., Hu, X., & Cahill, D. G. (2001) · Journal of Applied Physics · doi:10.1063/1.1406543 · Cited by 95
d’Acremont, Q., Pernot, G., Rampnoux, J.-M., Furlan, A., Lacroix, D., Ludwig, A., & Dilhaire, S. (2017) · Review of Scientific Instruments · doi:10.1063/1.4986469 · Cited by 11
Metadata
- Authors
- Wright, O. B.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1992-02-15
- Volume
- 71
- Issue
- 4
- Pages
- 1617-1629
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2013240111
- Cited by
- 126
- References
- 1
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thickness and sound velocity measurement in thin transparent films with laser picosecond acoustics. https://app.cochat.ai/papers/10.1063/1.351218
- The paper
- Wright, O. B. (1992). Thickness and sound velocity measurement in thin transparent films with laser picosecond acoustics. Journal of Applied Physics. https://doi.org/10.1063/1.351218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.