CoChat

Backward volume wave solitons in a yttrium iron garnet film (invited) (abstract)

Chen, Ming, Tsankov, Mincho A., Nash, Jon M., Patton, Carl E. · 1993 · Journal of Applied Physics
Cited by 23

The DOI matches its Crossref record.

Abstract

Solitons are nonlinear propagating wave pulses that preserve their shape without spreading. Recently, microwave envelope solitons have been observed in thin yttrium iron garnet (YIG) films for magnetostatic surface wave and forward volume wave configurations. In this work, we report the first observation of microwave envelope of magnetostatic backward volume waves (MSBVW) for an in-plane magnetized YIG film with waves propagating parallel to the magnetization direction. Both soliton profiles and the nonlinear peak power response were observed. The experiments were conducted using a microstrip magnetostatic wave delay line structure. A single crystal YIG film of 7.2 μm thickness, 2 mm×15 mm in size, and with unpinned surface spins was magnetized in-plane by a static external field of 1343 Oe along the long 15 mm edge. The 10 GHz ferromagnetic resonance linewidth of the film was 0.6 Oe. Square microwave pulses with pulse widths from 2 to 200 ns and a carrier frequency of 5.78 GHz were launched parallel to the field through a microstrip antenna. The output signal was received by a second microstrip antenna placed 4 mm downstream and analyzed in the time domain with a microwave transition analyzer. Envelope soliton behavior evident from the time resolved waveforms was observed for various input-power/pulse-width combinations. At relatively low power levels, one sees a broad output signal with a peak power increasing linearly with the input power. As the input power is increased above some threshold, a sharp soliton pulse emerges and the peak power increases more rapidly with input power than in the low power regime. The threshold varies with pulse width, as expected for solitons. A further increase of the input power produces multiple soliton profiles and a corresponding drop in the peak power. These results clearly demonstrate the existence of MSBVW solitons in YIG films. Dr. J. D. Adam of Westinghouse is acknowledged for providing the YIG films. This work was supported in part by the National Science Foundation, Grant No. DMR-8921761 and by the U. S. Army Research Office, Grant No. DAAL03-91-G-0327.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.354745

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 23

Metadata

Authors
Chen, M., Tsankov, M. A., Nash, J. M., & Patton, C. E.
Venue
Journal of Applied Physics
Published
1993-08-01
Volume
74
Issue
3
Pages
2146-2147
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W1990639435
Cited by
23
References
0
FWCI
0.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Backward volume wave solitons in a yttrium iron garnet film (invited) (abstract). https://app.cochat.ai/papers/10.1063/1.354745
The paper
Chen, M., Tsankov, M. A., Nash, J. M., & Patton, C. E. (1993). Backward volume wave solitons in a yttrium iron garnet film (invited) (abstract). Journal of Applied Physics. https://doi.org/10.1063/1.354745

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.