The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates
Open accessAbstract
In vivo transcranial and noninvasive cavitation detection with blood-brain barrier (BBB) opening in nonhuman primates is hereby reported. The BBB in monkeys was opened transcranically using focused ultrasound (FUS) in conjunction with microbubbles. A passive cavitation detector, confocal with the FUS transducer, was used to identify and monitor the bubble behavior. During sonication, the cavitation spectrum, which was found to be region-, pressure-, and bubble-dependent, provided real-time feedback regarding the opening occurrence and its properties. These findings demonstrate feasibility of transcranial, cavitation-guided BBB opening using FUS and microbubbles in noninvasive human applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A more localized transient disruption of BBB is accomplished by using magnetic resonance imaging-guided focused ultrasound in combination with IV infusion of microbubbles (FUS-MB) (Fig. 4b), which induce temporary BBB opening even in NHPs [134–137].”
From Designing and optimizing AAV-mediated gene therapy for neurodegenerative diseases: from bench to bedside (2024) · cites this paper as [134]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Blood-Brain Barrier in Health and Chronic Neurodegenerative Disorders
Zlokovic, B. V. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.003 · Cited by 3,280
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N. J., Vykhodtseva, N. I., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,463
Microbubble size isolation by differential centrifugation
Feshitan, J. A., Chen, C., Kwan, J. J., & Borden, M. A. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.09.066 · Cited by 447
Mechanisms of contrast agent destruction
Chomas, J. E., Dayton, P. A., Allen, J. S., Morgan, K. E., & Ferrara, K. W. (2001) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.896136 · Cited by 362
Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in MiceIn Vivo
Choi, J. J., Feshitan, J. A., Baseri, B., Wang, S., Tung, Y., Borden, M. A., & Konofagou, E. E. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034533 · Cited by 258
Self-citationTung, Y., Vlachos, F., Choi, J. J., Deffieux, T., Selert, K., & Konofagou, E. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/20/007 · Cited by 246
Self-citationTung, Y., Vlachos, F., Feshitan, J. A., Borden, M. A., & Konofagou, E. E. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3646905 · Cited by 195
Self-citationHynynen, K., McDannold, N., Martin, H., Jolesz, F. A., & Vykhodtseva, N. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00741-x · Cited by 144
Choi, J. J., Pernot, M., Brown, T. R., Small, S. A., & Konofagou, E. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/004 · Cited by 141
Self-citationLiu, H.-L., Wai, Y., Chen, W.-S., Chen, J.-C., Hsu, P.-H., Wu, X.-Y., Huang, W.-C., Yen, T., & Wang, J.-J. (2008) · Ultrasound in Medicine and Biology · doi:10.1016/j.ultrasmedbio.2008.01.011 · Cited by 139
Flagged first, then by citations
Research works printed but not linked: 1
- Noninvasive microbubble enhanced FUS BBB opening in vivo feasibility in nonhuman primates
Cited by
Sorted by citations
Items 101–119 of 119
Noninvasive focal gene transfer of chemogenetic proteins in the primate brain
Corigliano, M. R., Parks, T. V., Guretse, S. S., Letica, L., Rollin, I. Z., Pell, S. K. A., Campos, V. P., Szczupak, D., & Schaeffer, D. J. (2026) · Cell Reports Methods · doi:10.1016/j.crmeth.2026.101427 · Cited by 2
Li, N., & Li, F. (2026) · Advanced ultrasound in diagnosis and therapy · doi:10.26599/audt.2026.250050 · Cited by 1
Enhancement of direct brain infusion with focused ultrasound and microbubbles
Wang, S., Sun, T., Acosta, C., Karakatsani, M. E., Olumolade, O., Samiotaki, G., & Konofagou, E. E. (2014) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2014.0540 · Cited by 1
Self-citationWu, S.-Y., Downs, M. E., Sánchez, C. S., Teichert, T., Buch, A., Samiotaki, G., Marquet, F., Tung, Y., Chen, C., Ferrera, V. P., et al. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0307 · Cited by 1
Self-citationReal-time, transcranial monitoring of safe blood-brain barrier opening in non-human primates
Marquet, F., Wu, S.-Y., Tung, Y., Teichert, T., Downs, M. E., Wang, S., Ferrera, V. P., & Konofagou, E. E. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0059 · Cited by 1
Self-citationEmerging Engineering Technologies for Opening the BBB
Konofagou, E. (2014) · AAPS advances in the pharmaceutical sciences series · doi:10.1007/978-1-4614-9105-7_20 · Cited by 1
Self-citation(2012) · The Brain Sciences Journal · doi:10.7214/brainsciences/000 · Cited by 1
Optically Active Plasmonic Microbubbles
Dove, J. D. (2014) · CU Scholar (University of Colorado Boulder)
Focused Ultrasound Enhances Decision-Making in
Downs, M. E., Buch, A., Karakatsani, M. E., Teichert, T., Sierra, C., Chen, S., Konofagou, E. E., & Ferrera, V. P. (2016)
Self-citationValdez, M. A. (2017) · UA Campus Repository (The University of Arizona)
Intravenous and Intravascular Drug Delivery
Pan, J., Huang, Y., & Grant, G. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813997-4.00009-8
Optimization of Blood-Brain Barrier Opening with Focused Ultrasound: The Animal Perspective
Konofagou, E. E. (2022) · AAPS advances in the pharmaceutical sciences series · doi:10.1007/978-3-030-88773-5_20
Self-citationFocused ultrasound-mediated brain genome editingPreprint
Leong, K. W., Lao, Y., Ji, R., Zhou, J. K., Snow, K. J., Kwon, N., Saville, E., He, S., Chauhan, S., Chi, C., et al. (2023) · Research Square · doi:10.21203/rs.3.rs-2365576/v1
Self-citationCoenzyme II and Vascular Endothelium and Blood–Brain Barrier
Xu, H., & Gu, J. (2025) · Springer eBooks · doi:10.1007/978-981-97-9877-3_38
Liu, D., Shao, X., Silva, F. M., Sanatkhani, S., Lee, R., Konofagou, E. E., Wang, D. J., & Ferrera, V. P. (2026) · NeuroImage · doi:10.1016/j.neuroimage.2026.121805
Self-citationHow can we best utilize magnetic resonance for microbubble-mediated drug delivery to the brain
Huang, Y., & Hynynen, K. (2026) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2026.2711975
Metadata
- Authors
- Tung, Y.-S., Marquet, F., Teichert, T., Ferrera, V., & Konofagou, E. E.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2011-04-18
- Volume
- 98
- Issue
- 16
- Pages
- 163704-163704
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- PMC
- PMC3094460
- OpenAlex
- W2094621092
- Cited by
- 119
- References
- 13
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 4 · 2023: 9 · 2022: 6 · 2021: 8 · 2020: 8 · 2019: 5 · 2018: 6 · 2017: 6 · 2016: 13 · 2015: 14 · 2014: 10 · 2013: 8 · 2012: 10
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Applied Physics Letters (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Deutsche Forschungsgemeinschaft
- National Science Foundation (0644713, MH059244)
- National Institutes of Health (NIHR01EB009041)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Ultrasound and Cavitation Phenomena
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Keywords
- blood-brain barrier opening, focused ultrasound, microbubbles, cavitation detection, transcranial ultrasound, non-human primates, monkeys, passive cavitation detection, real-time feedback
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review