The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Superconducting a-WxSi1−x nanowire single-photon detector with saturated internal quantum efficiency from visible to 1850 nm
Abstract
We have developed a single-photon detector based on superconducting amorphous tungsten–silicon alloy (a-WxSi1−x) nanowire. Our device made from a uniform a-WxSi1−x nanowire covers a practical detection area (16 μm×16 μm) and shows high sensitivity featuring a plateau of the internal quantum efficiencies, i.e., efficiencies of generating an electrical pulse per absorbed photon, over a broad wavelength and bias range. This material system for superconducting nanowire detector technology could overcome the limitations of the prevalent nanowire devices based on NbN and lead to more practical, ideal single-photon detectors having high efficiency, low noise, and high count rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A scheme for efficient quantum computation with linear optics
Knill, E., Laflamme, R., & Milburn, G. J. (2001) · Nature · doi:10.1038/35051009 · Cited by 5,880
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Counting near-infrared single-photons with 95% efficiency
Lita, A. E., Miller, A. J., & Nam, S. W. (2008) · Optics Express · doi:10.1364/oe.16.003032 · Cited by 734
Self-citation
Cited by
Detecting single infrared photons with 93% system efficiency
Marsili, F., Verma, V. B., Stern, J. A., Harrington, S., Lita, A. E., Gerrits, T., Vayshenker, I., Baek, B., Shaw, M. D., Mirin, R. P., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.13 · Cited by 1,202
Self-citationSuperconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Silverstone, J. W., Bonneau, D., O'Brien, J. L., & Thompson, M. G. (2016) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2016.2573218 · Cited by 352
Dietrich, C. P., Fiore, A., Thompson, M. G., Kamp, M., & Höfling, S. (2016) · Laser & Photonics Reviews · doi:10.1002/lpor.201500321 · Cited by 266
State readout of a trapped ion qubit using a trap-integrated superconducting photon detector
Todaro, S. L., Verma, V. B., McCormick, K. C., Allcock, D. T. C., Mirin, R. P., Wineland, D. J., Nam, S. W., Wilson, A. C., Leibfried, D., & Slichter, D. H. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.010501 · Cited by 98
“2 in the main text) is generally accepted as evidence for saturation of the IDE close to unity [64], although definitive experiments to measure the IDE in these situations have”
BackgroundSelf-citation
Metadata
- Authors
- Baek, B., Lita, A. E., Verma, V., & Nam, S. W.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2011-06-20
- Volume
- 98
- Issue
- 25
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2043082409
- Cited by
- 160
- References
- 3
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.