Abstract
The carrier concentration of GaSb epitaxial layers grown from Sb-rich solutions by liquid-phase epitaxy is controlled by replacing nominally undoped GaSb by Te-doped polycrystalline GaSb to suppress or compensate the background hole concentration. The dependence of the 10 K photoluminescence peak wavelength and intensity on the doping level of the Te-compensated GaSb layers has been investigated. The absorption spectra are examined as a function of carrier concentration. Low-dopant-concentration p-type GaSb samples exhibit the band gap shrinkage with increasing hole concentration, while the lightly Te-doped n-type GaSb samples exhibit a band gap increase due to the Burstein–Moss shift with increasing electron concentration. By using Te-doped GaSb layers with an electron concentration of 5.6×1015 cm−3, the fabricated GaSb photodiodes exhibit a low dark current of 2 μA at −5 V, a high breakdown voltage of 28.7 V at 20 μA, and a maximum photoresponsivity of 0.55 A/W with an external quantum efficiency of 40% at 1.72 μm wavelength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anomalous Optical Absorption Limit in InSb
Burstein, E. (1954) · Physical Review · doi:10.1103/physrev.93.632 · Cited by 3,983
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Disorders of the Respiratory Muscles
Laghi, F., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2206020 · Cited by 687
Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1246oc · Cited by 359
Comparison of electrical and magnetic stimulations to assess quadriceps muscle function
Verges, S., Maffiuletti, N. A., Kerherve, H., Decorte, N., Wuyam, B., & Millet, G. Y. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01051.2007 · Cited by 168
Effects of lung volume on diaphragm EMG signal strength during voluntary contractions
Beck, J., Sinderby, C., Lindström, L., & Grassino, A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.3.1123 · Cited by 165
Metadata
- Authors
- Sun, Y.-M., Jiang, W.-J., & Wu, M.-C.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1996-08-01
- Volume
- 80
- Issue
- 3
- Pages
- 1731-1734
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2056382561
- Cited by
- 52
- References
- 1
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.