Cited by 10Ferroelectric and Piezoelectric MaterialsDielectric materials and actuatorsFerroelectric and Negative Capacitance Devices

Effects of surface morphology on retention loss of ferroelectric domains in poly(vinylidenefluoride-co-trifluoroethylene) thin films

Choi, Hyunwoo, Hong, Seungbum, Sung, Tae-Hyun, No, Kwangsoo·2011·Applied Physics Letters

Abstract

Effects of surface morphology on the retention loss of ferroelectric domains of poly(vinylidenefluoride-co-trifluoroethylene) thin films were investigated using piezoresponse force microscopy. We found that the retention loss occurred by nucleation of opposite domains at the regions with morphological gradients between 0.079 and 0.146. In addition, we observed collective decreases in piezoresponse amplitude of the opposite domains after 0.8 × 106 s, although each reversed domain showed different growth rate as evidenced by different threshold time for phase reversal. These results suggest that the surface morphology has a strong influence in determining the nucleation and growth kinetics by which the retention loss occurs.

Integrity signals

Registry

Crossref · 10.1063/1.3632042

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The retention time of P(VDF-TrFE) fabricated in the same method as the present patch is known as 0.8 × 106 seconds.

    “The retention time of P(VDF-TrFE) fabricated in a same method of the present patch is known as 0.8 × 106 seconds61.”

    From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [61]

Cites

Flagged first, then by citations

1 of the 12 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Choi, H., Hong, S., Sung, T.-H., & No, K.
Affiliations
  • Argonne National Laboratory (US)
  • Hanyang University 3 Department of Electrical Engineering, , Seoul 133-791, Korea
  • Korea Advanced Institute of Science and Technology (KR)
Venue
Applied Physics Letters
Published
2011-08-29
Volume
99
Issue
9
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2000479272
Cited by
10
References
12
Citations by year
2021: 2 · 2020: 2 · 2016: 1 · 2014: 1 · 2013: 1 · 2012: 2
FWCI
0.79
Type
journal article
Language
en
Open access
closed
Locations
Applied Physics Letters (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Dielectric materials and actuators
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Ferroelectric and Negative Capacitance Devices
Keywords
poly(vinylidene fluoride-trifluoroethylene), P(VDF-TrFE), ferroelectric domains, retention loss, surface morphology, domain nucleation, domain growth kinetics, morphological gradient, piezoresponse, phase reversal, thin films

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review