The DOI matches its Crossref record.
Parametric tip model and force–distance relation for Hamaker constant determination from atomic force microscopy
Abstract
Hamaker constants and dispersion forces interactions of materials are of increasing interest and the advent of atomic force microscopy (AFM) force measurements represents a new opportunity for quantitative studies of these interactions. A critical problem is the determination of a force–distance relation for realistic AFM probes. Due to the inadequacies of existing power-law sphere–plane models to describe the probe–sample system, we present a new parametric tip force–distance relation (PT/FDR). A surface integration method is developed to compute the interactions between arbitrarily shaped bodies. The method is based on the Hamaker pairwise integration in a continuous fashion, reducing the six-dimensional integration to a four-dimensional scheme. With this method, the PT/FDR is obtained and a nonlinear fitting routine is used to extract the model parameters and the Hamaker constant from AFM force–distance data. From the sensitivity analysis of the fitting of synthesized AFM force–distance data, one finds that, for large tip radius (compared to separation), the force is proportional to the product of the Hamaker constant and tip radius. Unique determination of the Hamaker constant can be achieved if a small radius tip is used in the AFM scan. By fitting to literature data, the effectiveness of the PT/FDR is shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Theories of scanning probe microscopes at the atomic scale
Hofer, W. A., Foster, A. S., & Shluger, A. L. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.1287 · Cited by 480
Perspectives on Mussel-Inspired Wet Adhesion
Ahn, B. K. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b13149 · Cited by 441
Anion Layering and Steric Hydration Repulsion on Positively Charged Surfaces in Aqueous Electrolytes
Hu, Q., Weber, C., Cheng, H., Renner, F. U., & Valtiner, M. (2017) · ChemPhysChem · doi:10.1002/cphc.201700865 · Cited by 23
Metadata
- Authors
- Argento, C., & French, R. H.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1996-12-01
- Volume
- 80
- Issue
- 11
- Pages
- 6081-6090
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2064756274
- Cited by
- 179
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parametric tip model and force–distance relation for Hamaker constant determination from atomic force microscopy. https://app.cochat.ai/papers/10.1063/1.363680
- The paper
- Argento, C., & French, R. H. (1996). Parametric tip model and force–distance relation for Hamaker constant determination from atomic force microscopy. Journal of Applied Physics. https://doi.org/10.1063/1.363680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.