Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 813

The DOI matches its Crossref record.

A perspective on paper-based microfluidics: Current status and future trends

Open access
Li, Xu, Ballerini, David R., Shen, Wei·2012·Biomicrofluidics

Abstract

“Paper-based microfluidics” or “lab on paper,” as a burgeoning research field with its beginning in 2007, provides a novel system for fluid handling and fluid analysis for a variety of applications including health diagnostics, environmental monitoring as well as food quality testing. The reasons why paper becomes an attractive substrate for making microfluidic systems include: (1) it is a ubiquitous and extremely cheap cellulosic material; (2) it is compatible with many chemical/biochemical/medical applications; and (3) it transports liquids using capillary forces without the assistance of external forces. By building microfluidic channels on paper, liquid flow is confined within the channels, and therefore, liquid flow can be guided in a controlled manner. A variety of 2D and even 3D microfluidic channels have been created on paper, which are able to transport liquids in the predesigned pathways on paper. At the current stage of its development, paper-based microfluidic system is claimed to be low-cost, easy-to-use, disposable, and equipment-free, and therefore, is a rising technology particularly relevant to improving the healthcare and disease screening in the developing world, especially for those areas with no- or low-infrastructure and limited trained medical and health professionals. The research in paper-based microfluidics is experiencing a period of explosion; most published works have focused on: (1) inventing low-cost and simple fabrication techniques for paper-based microfluidic devices; and (2) exploring new applications of paper-based microfluidics by incorporating efficient detection methods. This paper aims to review both the fabrication techniques and applications of paper-based microfluidics reported to date. This paper also attempts to convey to the readers, from the authors’ point of view the current limitations of paper-based microfluidics which require further research, and a few perspective directions this new analytical system may take in its development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.3687398

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 813

Metadata

Authors
Li, X., Ballerini, D. R., & Shen, W.
Venue
Biomicrofluidics
Published
2012-03-01
Volume
6
Issue
1
Pages
11301-1130113
ISSN
1932-1058 (ISSN-L)
OpenAlex
W2008654270
Cited by
813
References
0
FWCI
39.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A perspective on paper-based microfluidics: Current status and future trends. https://app.cochat.ai/papers/10.1063/1.3687398
The paper
Li, X., Ballerini, D. R., & Shen, W. (2012). A perspective on paper-based microfluidics: Current status and future trends. Biomicrofluidics. https://doi.org/10.1063/1.3687398

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.