The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
A perspective on paper-based microfluidics: Current status and future trends
Open accessAbstract
“Paper-based microfluidics” or “lab on paper,” as a burgeoning research field with its beginning in 2007, provides a novel system for fluid handling and fluid analysis for a variety of applications including health diagnostics, environmental monitoring as well as food quality testing. The reasons why paper becomes an attractive substrate for making microfluidic systems include: (1) it is a ubiquitous and extremely cheap cellulosic material; (2) it is compatible with many chemical/biochemical/medical applications; and (3) it transports liquids using capillary forces without the assistance of external forces. By building microfluidic channels on paper, liquid flow is confined within the channels, and therefore, liquid flow can be guided in a controlled manner. A variety of 2D and even 3D microfluidic channels have been created on paper, which are able to transport liquids in the predesigned pathways on paper. At the current stage of its development, paper-based microfluidic system is claimed to be low-cost, easy-to-use, disposable, and equipment-free, and therefore, is a rising technology particularly relevant to improving the healthcare and disease screening in the developing world, especially for those areas with no- or low-infrastructure and limited trained medical and health professionals. The research in paper-based microfluidics is experiencing a period of explosion; most published works have focused on: (1) inventing low-cost and simple fabrication techniques for paper-based microfluidic devices; and (2) exploring new applications of paper-based microfluidics by incorporating efficient detection methods. This paper aims to review both the fabrication techniques and applications of paper-based microfluidics reported to date. This paper also attempts to convey to the readers, from the authors’ point of view the current limitations of paper-based microfluidics which require further research, and a few perspective directions this new analytical system may take in its development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angewandte Chemie International Edition
(2006) · Angewandte Chemie International Edition · doi:10.1002/(issn)1521-3773 · Cited by 5,242
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays
Zhao, W., Brook, M. A., & Li, Y. (2008) · ChemBioChem · doi:10.1002/cbic.200800282 · Cited by 768
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Wood-Derived Materials for Green Electronics, Biological Devices, and Energy Applications
Zhu, H., Luo, W., Ciesielski, P. N., Fang, Z., Zhu, J. Y., Henriksson, G., Himmel, M. E., & Hu, L. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00225 · Cited by 1,532
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Recent Advances in Paper-Based Sensors
Liana, D. D., Raguse, B., Gooding, J. J., & Chow, E. (2012) · Sensors · doi:10.3390/s120911505 · Cited by 660
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Surface Acoustic Wave Microfluidics
Yeo, L. Y., & Friend, J. R. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141418 · Cited by 561
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
McConnell, E. M., Cozma, I., Mou, Q., Brennan, J. D., Lu, Y., & Li, Y. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00240f · Cited by 477
Emerging Applications of Superhydrophilic‐Superhydrophobic Micropatterns
Ueda, E., & Levkin, P. A. (2013) · Advanced Materials · doi:10.1002/adma.201204120 · Cited by 474
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.037 · Cited by 434
Nanocellulose in Sensing and Biosensing
Golmohammadi, H., Morales-Narváez, E., Naghdi, T., & Merkoçi, A. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b01170 · Cited by 402
From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare
Andreu-Perez, J., Leff, D. R., Ip, H. M. D., & Yang, G.-Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422751 · Cited by 383
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Recent developments in computer vision-based analytical chemistry: A tutorial review
Capitán-Vallvey, L. F., López-Ruiz, N., Martínez-Olmos, A., Erenas, M. M., & Palma, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.10.009 · Cited by 341
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Cellulose: from biocompatible to bioactive material
Credou, J., & Berthelot, T. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00431k · Cited by 335
Advances in Paper-Based Analytical Devices
Ozer, T., McMahon, C., & Henry, C. S. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114845 · Cited by 330
Biodegradable Materials for Sustainable Health Monitoring Devices
Hosseini, E. S., Dervin, S., Ganguly, P., & Dahiya, R. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01139 · Cited by 326
Sahlgren, C., Meinander, A., Zhang, H., Cheng, F., Preis, M., Xu, C., Salminen, T. A., Toivola, D., Abankwa, D., Rosling, A., et al. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700258 · Cited by 315
Li, J., Rossignol, F., & Macdonald, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00235d · Cited by 307
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Paper-Based Sensors: Emerging Themes and Applications
Singh, A. T., Lantigua, D., Meka, A., Taing, S., Pandher, M., & Camci-Unal, G. (2018) · Sensors · doi:10.3390/s18092838 · Cited by 284
Paper based diagnostics for personalized health care: Emerging technologies and commercial aspects
Mahato, K., Srivastava, A., & Chandra, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.001 · Cited by 280
Portable analytical platforms for forensic chemistry: A review
de Araujo, W. R., Cardoso, T. M. G., da Rocha, R. G., Santana, M. H. P., Muñoz, R. A. A., Richter, E. M., Paixão, T. R. L. C., & Coltro, W. K. T. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.06.014 · Cited by 280
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms
Sanjay, S. T., Fu, G., Dou, M., Xu, F., Liu, R., Qi, H., & Li, X. (2015) · The Analyst · doi:10.1039/c5an00780a · Cited by 267
Self-citationNucleic Acid Tests for Clinical Translation
Li, M., Yin, F., Song, L., Mao, X., Li, F., Fan, C., Zuo, X., & Xia, Q. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00241 · Cited by 264
Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602659 · Cited by 262
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Acoustically-driven thread-based tuneable gradient generators
Ramesan, S., Rezk, A. R., Cheng, K. W., Chan, P. P. Y., & Yeo, L. Y. (2016) · Lab on a Chip · doi:10.1039/c5lc00937e · Cited by 33
Metadata
- Authors
- Li, X., Ballerini, D. R., & Shen, W.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2012-03-01
- Volume
- 6
- Issue
- 1
- Pages
- 11301-1130113
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2008654270
- Cited by
- 813
- References
- 39
- FWCI
- 39.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.