The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Proposal for tunnel-field-effect-transistor as ultra-sensitive and label-free biosensors
Abstract
Tunnel field-effect-transistor (TFET) based biosensor is proposed, and it is shown that they can surpass by several orders, the performance of those based on conventional FET (CFET) and hence, can potentially revolutionize the biosensing applications. Analytical formula is derived for the sensitivity and response time to provide physical insights in terms of material bandgap and operation regime of the TFET biosensor for achieving optimal results. At the same time, rigorous numerical simulations have been performed in order to obtain accurate values of sensitivity for both biomolecule and pH sensing operations. The time dependent response of the biosensors has also been discussed through analytical and numerical solutions. It is shown that while the CFET biosensors suffer from fundamental limitations on the maximum sensitivity and minimum detection time achievable, TFET biosensors, with their fundamentally different current injection mechanism in the form of band-to-band tunneling, can overcome such limitations and lead to over four orders of magnitude higher sensitivity and over an order of magnitude lower response time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Band structure of indium antimonide
Kane, E. O. (1957) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(57)90013-6 · Cited by 3,701
Scaling the Si MOSFET: from bulk to SOI to bulk
Yan, R.-H., Ourmazd, A., & Lee, K. F. (1992) · IEEE Transactions on Electron Devices · doi:10.1109/16.141237 · Cited by 910
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Electronic detection of DNA by its intrinsic molecular charge
Fritz, J., Cooper, E. B., Gaudet, S., Sorger, P. K., & Manalis, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232276699 · Cited by 443
Gandhi, R., Chen, Z., Singh, N., Banerjee, K., & Lee, S. (2011) · IEEE Electron Device Letters · doi:10.1109/led.2011.2106757 · Cited by 341
Self-citationPerformance limits of nanobiosensors
Nair, P. R., & Alam, M. A. (2006) · Applied Physics Letters · doi:10.1063/1.2211310 · Cited by 341
Direct Detection of the Hybridization of Synthetic Homo-Oligomer DNA Sequences by Field Effect
Souteyrand, E., Cloarec, J. P., Martin, J. R., Wilson, C., Lawrence, I., Mikkelsen, S., & Lawrence, M. F. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963056h · Cited by 340
Waleed Shinwari, M., Jamal Deen, M., & Landheer, D. (2007) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.10.003 · Cited by 268
Screening-Limited Response of NanoBiosensors
Nair, P. R., & Alam, M. A. (2008) · Nano Letters · doi:10.1021/nl072593i · Cited by 227
Noise considerations in field-effect biosensors
Deen, M. J., Shinwari, M. W., Ranuárez, J. C., et al. (2006) · Journal of Applied Physics · doi:10.1063/1.2355542 · Cited by 131
Sarkar, D., Krall, M., & Banerjee, K. (2010) · Applied Physics Letters · doi:10.1063/1.3528338 · Cited by 41
Self-citationThe effect of DNA probe distribution on the reliability of label-free biosensors
Shinwari, M. W., Shinwari, M. F., Deen, M. J., & Selvaganapathy, P. R. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.08.006 · Cited by 16
Cited by
MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
Sarkar, D., Liu, W., Xie, X., Anselmo, A. C., Mitragotri, S., & Banerjee, K. (2014) · ACS Nano · doi:10.1021/nn5009148 · Cited by 1,047
Self-citationA subthermionic tunnel field-effect transistor with an atomically thin channel
Sarkar, D., Xie, X., Liu, W., Cao, W., Kang, J., Gong, Y., Kraemer, S., Ajayan, P. M., & Banerjee, K. (2015) · Nature · doi:10.1038/nature15387 · Cited by 972
Self-citationSarkar, D., Xie, X., Kang, J., Zhang, H., Liu, W., Navarrete, J., Moskovits, M., & Banerjee, K. (2015) · Nano Letters · doi:10.1021/nl504454u · Cited by 395
Self-citationTwo-dimensional Layered MoS2 Biosensors Enable Highly Sensitive Detection of Biomolecules
Lee, J., Dak, P., Lee, Y., Park, H., Choi, W., Alam, M. A., & Kim, S. (2014) · Scientific Reports · doi:10.1038/srep07352 · Cited by 318
Comparative analysis of dielectric- modulated FET and TFET-based biosensor
Narang, R., Saxena, M., & Gupta, M. (2015) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2015.2396899 · Cited by 296
Metadata
- Authors
- Sarkar, D., & Banerjee, K.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2012-04-02
- Volume
- 100
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1992333614
- Cited by
- 295
- References
- 13
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.