Current source imaging for high spatial resolution magnetocardiography in normal and abnormal rat cardiac muscles
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The purpose of our study was to identify the current source produced by acute ischemia and infarction. We measured magnetocardiograms (MCG) and electrocardiograms (ECG) of five male rats using a high-resolution dc superconducting quantum interference device gradiometer in a magnetically shielded room after performing coronary artery occlusion. The spatial resolution of the detecting magnetic field of our system is higher than the typical system, thus permitting the measurement of magnetic fields in small animals. Distribution of the magnetic fields B(t) and distribution of |rot B(t)|, which corresponded to the distribution of the current source, were imaged by 12-channel MCGs. As a result, the distribution of current source changes in the affected area of the myocardium during the ST segment, and amplitude of the peak significantly increased after occlusion. Our system can be used to help clarify the mechanism of the ST shift related to severe heart disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Cohen, D., & Kaufman, L. A. (1975) · Circulation Research · doi:10.1161/01.res.36.3.414 · Cited by 131
Magnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
Magnetocardiography: clinical investigations with a biomagnetic multichannel system
Achenbach, S., & Moshage, W. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/4a/011 · Cited by 20
Clinical magnetocardiography: experience with a biomagnetic multichannel system
Moshage, W., Achenbach, S., Weikl, A., Göhl, K., Bachmann, K., Abraham-Fuchs, K., Härer, W., & Schneider, S. (1991) · The International Journal of Cardiac Imaging · doi:10.1007/bf01797754 · Cited by 17
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Brisinda, D., Caristo, M. E., & Fenici, R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01048.2005 · Cited by 23
Brisinda, D., Caristo, M. E., & Fenici, R. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/8/002 · Cited by 9
Metadata
- Authors
- Uchida, S., Iramina, K., Goto, K., & Ueno, S.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2000-05-01
- Volume
- 87
- Issue
- 9
- Pages
- 6205-6207
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2032526700
- Cited by
- 15
- References
- 6
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.