Abstract

The purpose of our study was to identify the current source produced by acute ischemia and infarction. We measured magnetocardiograms (MCG) and electrocardiograms (ECG) of five male rats using a high-resolution dc superconducting quantum interference device gradiometer in a magnetically shielded room after performing coronary artery occlusion. The spatial resolution of the detecting magnetic field of our system is higher than the typical system, thus permitting the measurement of magnetic fields in small animals. Distribution of the magnetic fields B(t) and distribution of |rot B(t)|, which corresponded to the distribution of the current source, were imaged by 12-channel MCGs. As a result, the distribution of current source changes in the affected area of the myocardium during the ST segment, and amplitude of the peak significantly increased after occlusion. Our system can be used to help clarify the mechanism of the ST shift related to severe heart disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.372655

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Uchida, S., Iramina, K., Goto, K., & Ueno, S.
Venue
Journal of Applied Physics
Published
2000-05-01
Volume
87
Issue
9
Pages
6205-6207
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2032526700
Cited by
15
References
6
FWCI
0.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.