The DOI matches its Crossref record.
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Abstract
A mass spectrometer system which is capable of sampling ions directly from an atmospheric pressure source has been constructed and used to investigate ions which are evaporated from the surface of highly charged water droplets. Solutions of electrolytes are sprayed into the air, and a large charge imparted to the droplets by induction; an electric field applied across the plume of evaporating spray extracts small ions, probably already clustered with solvent molecules, which are drawn through a 25 μm orifice into the vacuum chamber. Differential pumping is applied and the ions are focused into a quadrupole mass filter. Approximately 30 univalent anions and cations of various sizes and structures have been tested, and almost all have been observed to evaporate; significant exceptions are Ag+, Tl+, and Cu+. Furthermore, certain molecules such as urea and acetanilide, when present as neutrals in the sprayed water, are observed to remain attached to the ions when these evaporate. The experimental results are discussed: ion mass spectra are interpreted in terms of ion evaporation (or field emission) and ion–molecule reactions in gas phase, and the potential value of the process for ion research and analytical applications is considered. The main features of the experimental results are consistent with the predictions of the theory developed in a previous paper by the authors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
The Fluid Dynamics of Taylor Cones
Fernández de la Mora, J. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110159 · Cited by 594
Metadata
- Authors
- Thomson, B. A., & Iribarne, J. V.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1979-12-01
- Volume
- 71
- Issue
- 11
- Pages
- 4451-4463
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2032194486
- Cited by
- 631
- References
- 0
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Field induced ion evaporation from liquid surfaces at atmospheric pressure. https://app.cochat.ai/papers/10.1063/1.438198
- The paper
- Thomson, B. A., & Iribarne, J. V. (1979). Field induced ion evaporation from liquid surfaces at atmospheric pressure. The Journal of Chemical Physics. https://doi.org/10.1063/1.438198
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.