The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Abstract
A mass spectrometer system which is capable of sampling ions directly from an atmospheric pressure source has been constructed and used to investigate ions which are evaporated from the surface of highly charged water droplets. Solutions of electrolytes are sprayed into the air, and a large charge imparted to the droplets by induction; an electric field applied across the plume of evaporating spray extracts small ions, probably already clustered with solvent molecules, which are drawn through a 25 μm orifice into the vacuum chamber. Differential pumping is applied and the ions are focused into a quadrupole mass filter. Approximately 30 univalent anions and cations of various sizes and structures have been tested, and almost all have been observed to evaporate; significant exceptions are Ag+, Tl+, and Cu+. Furthermore, certain molecules such as urea and acetanilide, when present as neutrals in the sprayed water, are observed to remain attached to the ions when these evaporate. The experimental results are discussed: ion mass spectra are interpreted in terms of ion evaporation (or field emission) and ion–molecule reactions in gas phase, and the potential value of the process for ion research and analytical applications is considered. The main features of the experimental results are consistent with the predictions of the theory developed in a previous paper by the authors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern Aspects of Electrochemistry
(2002) · Modern Aspects of Electrochemistry · doi:10.1007/b114168 · Cited by 5,949
Volumen und Hydratationswärme der Ionen
Born, M. (1920) · Zeitschrift für Physik · doi:10.1007/bf01881023 · Cited by 2,360
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Self-citation
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
The Fluid Dynamics of Taylor Cones
Fernández de la Mora, J. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110159 · Cited by 594
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Enke, C. G. (1997) · Analytical Chemistry · doi:10.1021/ac970095w · Cited by 419
Nanoelectrospray—More than just a minimized-flow electrospray ionization source
Juraschek, R., Dülcks, T., & Karas, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00157-3 · Cited by 415
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Electrospray mass spectrometry applied to inorganic and organometallic chemistry
Colton, R., D'Agostino, A., & Traeger, J. C. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140203 · Cited by 379
Mechanistic aspects of electrospray ionization
Bruins, A. P. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01110-2 · Cited by 368
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
Buhrman, D. L., Price, P. I., & Rudewiczcor, P. J. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00072-4 · Cited by 364
Chen, P. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200200560 · Cited by 363
On the mechanisms by which the charged droplets produced by electrospray lead to gas phase ions
Kebarle, P., & Peschke, M. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00598-x · Cited by 352
LC/MS applications in drug development
Lee, M. S., & Kerns, E. H. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:3/4<187::aid-mas2>3.0.co;2-k · Cited by 339
Internal energy and fragmentation of ions produced in electrospray sources
Gabelica, V., & Pauw, E. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20027 · Cited by 338
Development of probe electrospray using a solid needle
Hiraoka, K., Nishidate, K., Mori, K., Asakawa, D., & Suzuki, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3201 · Cited by 328
Electrochemical processes in electrospray ionization mass spectrometry
Mora, J. F. D. L., Van Berkel, G. J., Enke, C. G., Cole, R. B., Martinez-Sanchez, M., & Fenn, J. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200008)35:8<939::aid-jms36>3.0.co;2-v · Cited by 320
Principles of Electrospray Ionization
Wilm, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009407 · Cited by 311
Investigations of the electrospray interface for liquid chromatography/mass spectrometry
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1990) · Analytical Chemistry · doi:10.1021/ac00208a012 · Cited by 293
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D. (1990) · Analytical Chemistry · doi:10.1021/ac00206a009 · Cited by 274
State-of-the-art in liquid chromatography–mass spectrometry
Niessen, W. M. A. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00480-x · Cited by 267
Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry
Purves, R. W., & Guevremont, R. (1999) · Analytical Chemistry · doi:10.1021/ac981380y · Cited by 265
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Self-citationRomero-Sanz, I., Bocanegra, R., Fernandez de la Mora, J., & Gamero-Castaño, M. (2003) · Journal of Applied Physics · doi:10.1063/1.1598281 · Cited by 257
Of protons or proteins: “A beam's a beam for a' that.” (O.S. Burns)
Meng, C. K., Mann, M., & Fenn, J. B. (1988) · Zeitschrift für Physik D Atoms, Molecules and Clusters · doi:10.1007/bf01384871 · Cited by 254
From QCEIMS to QCxMS: A Tool to Routinely Calculate CID Mass Spectra Using Molecular Dynamics
Koopman, J., & Grimme, S. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00098 · Cited by 80
Metadata
- Authors
- Thomson, B. A., & Iribarne, J. V.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1979-12-01
- Volume
- 71
- Issue
- 11
- Pages
- 4451-4463
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2032194486
- Cited by
- 631
- References
- 4
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.