The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Abstract
A mass spectrometer system which is capable of sampling ions directly from an atmospheric pressure source has been constructed and used to investigate ions which are evaporated from the surface of highly charged water droplets. Solutions of electrolytes are sprayed into the air, and a large charge imparted to the droplets by induction; an electric field applied across the plume of evaporating spray extracts small ions, probably already clustered with solvent molecules, which are drawn through a 25 μm orifice into the vacuum chamber. Differential pumping is applied and the ions are focused into a quadrupole mass filter. Approximately 30 univalent anions and cations of various sizes and structures have been tested, and almost all have been observed to evaporate; significant exceptions are Ag+, Tl+, and Cu+. Furthermore, certain molecules such as urea and acetanilide, when present as neutrals in the sprayed water, are observed to remain attached to the ions when these evaporate. The experimental results are discussed: ion mass spectra are interpreted in terms of ion evaporation (or field emission) and ion–molecule reactions in gas phase, and the potential value of the process for ion research and analytical applications is considered. The main features of the experimental results are consistent with the predictions of the theory developed in a previous paper by the authors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern Aspects of Electrochemistry
(2002) · Modern Aspects of Electrochemistry · doi:10.1007/b114168 · Cited by 5,949
Volumen und Hydratationswärme der Ionen
Born, M. (1920) · Zeitschrift für Physik · doi:10.1007/bf01881023 · Cited by 2,360
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Self-citation
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Metadata
- Authors
- Thomson, B. A., & Iribarne, J. V.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1979-12-01
- Volume
- 71
- Issue
- 11
- Pages
- 4451-4463
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2032194486
- Cited by
- 631
- References
- 4
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.