A microfabricated ion trap with integrated microwave circuitry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We describe the design, fabrication, and testing of a surface-electrode ion trap, which incorporates microwave waveguides, resonators, and coupling elements for the manipulation of trapped ion qubits using near-field microwaves. The trap is optimised to give a large microwave field gradient to allow state-dependent manipulation of the ions' motional degrees of freedom, the key to multi-qubit entanglement. The microwave field near the centre of the trap is characterised by driving hyperfine transitions in a single laser-cooled 43Ca+ ion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Hite, D. A., Colombe, Y., Wilson, A. C., Brown, K. R., Warring, U., Jördens, R., Jost, J. D., McKay, K. S., Pappas, D. P., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.103001 · Cited by 176
Cavity QED in a molecular ion trap
Schuster, D. I., Bishop, L. S., Chuang, I. L., DeMille, D., & Schoelkopf, R. J. (2011) · Physical Review A · doi:10.1103/physreva.83.012311 · Cited by 61
Cited by
Trapped-ion quantum computing: Progress and challenges
Bruzewicz, C. D., Chiaverini, J., McConnell, R., & Sage, J. M. (2019) · Applied Physics Reviews · doi:10.1063/1.5088164 · Cited by 1,483
High-Fidelity Preparation, Gates, Memory, and Readout of a Trapped-Ion Quantum Bit
Harty, T. P., Allcock, D. T. C., Ballance, C. J., Guidoni, L., Janacek, H. A., Linke, N. M., Stacey, D. N., & Lucas, D. M. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.220501 · Cited by 632
Self-citationIon-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
Shuttling-based trapped-ion quantum information processing
Kaushal, V., Lekitsch, B., Stahl, A., Hilder, J., Pijn, D., Schmiegelow, C., Bermudez, A., Müller, M., Schmidt-Kaler, F., & Poschinger, U. (2020) · AVS Quantum Science · doi:10.1116/1.5126186 · Cited by 141
Materials challenges for trapped-ion quantum computers
Brown, K. R., Chiaverini, J., Sage, J. M., & Häffner, H. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00292-1 · Cited by 120
Heating rates and ion-motion control in a Y -junction surface-electrode trap
Shu, G., Vittorini, G., Buikema, A., Nichols, C. S., Volin, C., Stick, D., & Brown, K. R. (2014) · Physical Review A · doi:10.1103/physreva.89.062308 · Cited by 58
How to Wire a 1000 -Qubit Trapped-Ion Quantum Computer
Malinowski, M., Allcock, D. T. C., & Ballance, C. J. (2023) · PRX Quantum · doi:10.1103/prxquantum.4.040313 · Cited by 54
“Furthermore, it is possible to achieve Ω(y = 0) ≈ 0, for example by exploiting polarization selection rules [55], or using multiple parallel microwave lines [56, 57].”
BackgroundSelf-citationProbing Qubit Memory Errors at the Part-per-Million Level
Sepiol, M. A., Hughes, A. C., Tarlton, J. E., Nadlinger, D. P., Ballance, T. G., Ballance, C. J., Harty, T. P., Steane, A. M., Goodwin, J. F., & Lucas, D. M. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.110503 · Cited by 31
Self-citation
Metadata
- Authors
- Allcock, D. T. C., Harty, T. P., Ballance, C. J., Keitch, B. C., Linke, N. M., Stacey, D. N., & Lucas, D. M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2013-01-28
- Volume
- 102
- Issue
- 4
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2003328487
- Cited by
- 49
- References
- 3
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.