CoChat

High aspect ratio β-MnO2 nanowires and sensor performance for explosive gases

Xiao, J., Liu, P., Liang, Y., Li, H. B., Yang, G. W. · 2013 · Journal of Applied Physics

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

High aspect ratio β-MnO2 nanowires have been synthesized based on a facile and green technique without any chemical additive. The precursor solution of Mn3O4 nanocrystals was first synthesized by laser ablation of a manganese target in deionized water. Due to the high reactive and fresh surface of Mn3O4 nanocrystals produced by laser ablation in liquid, these nanocrystals were spontaneously assembled into the γ-MnOOH nanowires in the precursor solution after aging at room temperature. The high aspect ratio β-MnO2 nanowires were finally produced by the γ-MnOOH nanowires annealing at 300 °C for 3 h. For the high aspect ratio β-MnO2 nanowires, the high specific surface area is advantaged for gas absorption and the unique tunnel structure is good for gas molecule trapping. A gas sensor was made from the β-MnO2 nanowires for explosive gases. The investigations were carried out for the detection of various concentration of H2 at different temperatures, and the results demonstrated that the fabricated gas sensor can detect H2 down to 20 ppm with the sensitivity of 0.5 at 300 °C and short response time of 10s. For sensing CO and ethanol, the detecting concentration reached to 20 ppm at an operation temperature of 150 and 250 °C, respectively. These results can be comparable to that of the current advanced gas sensors made from metal oxide such as ZnO and SnO2, which showing that high aspect ratio β-MnO2 nanowires can be regarded as desirable candidate materials for fabricating gas sensors.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.4819218

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 45

Metadata

Authors
Xiao, J., Liu, P., Liang, Y., Li, H. B., & Yang, G. W.
Affiliations
Sun Yat-sen University (CN)
Venue
Journal of Applied Physics
Published
2013-08-21
Volume
114
Issue
7
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2046593772
Cited by
45
References
43
Citations by year
2026: 1 · 2025: 4 · 2024: 1 · 2023: 6 · 2022: 3 · 2021: 3 · 2020: 7 · 2019: 2 · 2018: 9 · 2017: 4 · 2015: 4 · 2014: 1
FWCI
1.00
Type
journal article
Language
en
Open access
closed
Locations
Journal of Applied Physics (publishedVersion)
Funders
  • National Natural Science Foundation of China
  • Natural Science Foundation of Guangdong Province
  • National Key Research and Development Program of China
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Materials Science › Materials Chemistry › Chemical and Physical Properties of Materials
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
manganese dioxide, high aspect ratio nanowires, hydrogen detection, carbon monoxide detection, ethanol detection, laser ablation in liquid, metal oxide gas sensors, gas adsorption

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.