The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
3D printed microfluidic devices with integrated valves
Open accessAbstract
We report the successful fabrication and testing of 3D printed microfluidic devices with integrated membrane-based valves. Fabrication is performed with a low-cost commercially available stereolithographic 3D printer. Horizontal microfluidic channels with designed rectangular cross sectional dimensions as small as 350 μm wide and 250 μm tall are printed with 100% yield, as are cylindrical vertical microfluidic channels with 350 μm designed (210 μm actual) diameters. Based on our previous work [Rogers et al., Anal. Chem. 83, 6418 (2011)], we use a custom resin formulation tailored for low non-specific protein adsorption. Valves are fabricated with a membrane consisting of a single build layer. The fluid pressure required to open a closed valve is the same as the control pressure holding the valve closed. 3D printed valves are successfully demonstrated for up to 800 actuations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Evaluation of 3D Printing and Its Potential Impact on Biotechnology and the Chemical Sciences
Gross, B. C., Erkal, J. L., Lockwood, S. Y., Chen, C., & Spence, D. M. (2014) · Analytical Chemistry · doi:10.1021/ac403397r · Cited by 1,746
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Self-citationProjection micro-stereolithography using digital micro-mirror dynamic mask
Sun, C., Fang, N., Wu, D. M., & Zhang, X. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.12.011 · Cited by 880
Microfluidics-based diagnostics of infectious diseases in the developing world
Chin, C. D., Laksanasopin, T., Cheung, Y. K., Steinmiller, D., Linder, V., Parsa, H., Wang, J., Moore, H., Rouse, R., Umviligihozo, G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2408 · Cited by 759
Integrated 3D-printed reactionware for chemical synthesis and analysis
Symes, M. D., Kitson, P. J., Yan, J., Richmond, C. J., Cooper, G. J. T., Bowman, R. W., Vilbrandt, T., & Cronin, L. (2012) · Nature Chemistry · doi:10.1038/nchem.1313 · Cited by 617
Cost-Effective Three-Dimensional Printing of Visibly Transparent Microchips within Minutes
Shallan, A. I., Smejkal, P., Corban, M., Guijt, R. M., & Breadmore, M. C. (2014) · Analytical Chemistry · doi:10.1021/ac4041857 · Cited by 501
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
Configurable 3D-Printed millifluidic and microfluidic ‘lab on a chip’ reactionware devices
Kitson, P. J., Rosnes, M. H., Sans, V., Dragone, V., & Cronin, L. (2012) · Lab on a Chip · doi:10.1039/c2lc40761b · Cited by 484
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Fabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices
Au, A. K., Lee, W., & Folch, A. (2014) · Lab Chip · doi:10.1039/c3lc51360b · Cited by 380
Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays
Saliba, A.-E., Saias, L., Psychari, E., Minc, N., Simon, D., Bidard, F.-C., Mathiot, C., Pierga, J.-Y., Fraisier, V., Salamero, J., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001515107 · Cited by 337
Moltzahn, F., Olshen, A. B., Baehner, L., Peek, A., Fong, L., Stöppler, H., Simko, J., Hilton, J. F., Carroll, P., & Blelloch, R. (2011) · Cancer Research · doi:10.1158/0008-5472.can-10-1229 · Cited by 322
Discrete elements for 3D microfluidics
Bhargava, K. C., Thompson, B., & Malmstadt, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1414764111 · Cited by 298
Zheng, X., Deotte, J., Alonso, M. P., Farquar, G. R., Weisgraber, T. H., Gemberling, S., Lee, H., Fang, N., & Spadaccini, C. M. (2012) · Review of Scientific Instruments · doi:10.1063/1.4769050 · Cited by 267
Hu, M., Yan, J., He, Y., Lu, H., Weng, L., Song, S., Fan, C., & Wang, L. (2010) · ACS Nano · doi:10.1021/nn901404h · Cited by 258
A 3D Printed Fluidic Device that Enables Integrated Features
Anderson, K. B., Lockwood, S. Y., Martin, R. S., & Spence, D. M. (2013) · Analytical Chemistry · doi:10.1021/ac4009594 · Cited by 229
Chikkaveeraiah, B. V., Mani, V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.005 · Cited by 220
Malhotra, R., Patel, V., Chikkaveeraiah, B. V., Munge, B. S., Cheong, S. C., Zain, R. B., Abraham, M. T., Dey, D. K., Gutkind, J. S., & Rusling, J. F. (2012) · Analytical Chemistry · doi:10.1021/ac301392g · Cited by 207
Kitson, P. J., Symes, M. D., Dragone, V., & Cronin, L. (2013) · Chem. Sci. · doi:10.1039/c3sc51253c · Cited by 180
Huang, B., Wu, H., Kim, S., & Zare, R. N. (2005) · Lab on a Chip · doi:10.1039/b509251e · Cited by 135
Rapid, femtomolar bioassays in complex matrices combining microfluidics and magnetoelectronics
Mulvaney, S. P., Cole, C. L., Kniller, M. D., Malito, M. P., Tamanaha, C. R., Rife, J. C., Stanton, M., & Whitman, L. J. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.03.029 · Cited by 120
Lab‐on‐a‐chip for oral cancer screening and diagnosis
Ziober, B. L., Mauk, M. G., Falls, E. M., et al. (2007) · Head & Neck · doi:10.1002/hed.20680 · Cited by 98
Label-free virus detection using silicon photonic microring resonators
McClellan, M. S., Domier, L. L., & Bailey, R. C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.056 · Cited by 96
Shah, J. J., Geist, J., Locascio, L. E., et al. (2006) · Electrophoresis · doi:10.1002/elps.200600118 · Cited by 70
Microfluidic-based enzymatic on-chip labeling of miRNAs
Vorwerk, S., Ganter, K., Cheng, Y., Hoheisel, J. D., Stähler, P. F., & Beier, M. (2008) · New Biotechnology · doi:10.1016/j.nbt.2008.08.005 · Cited by 67
Godwin, L. A., Pilkerton, M. E., Deal, K. S., Wanders, D., Judd, R. L., & Easley, C. J. (2011) · Analytical Chemistry · doi:10.1021/ac201598b · Cited by 49
Microfluidic valves made from polymerized polyethylene glycol diacrylate
Rogers, C. I., Oxborrow, J., Anderson, R., Tsai, L.-F., Nordin, G. P., & Woolley, A. T. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.10.008 · Cited by 46
Self-citationDynamic monitoring of glucagon secretion from living cells on a microfluidic chip
Shackman, J. G., Reid, K. R., Dugan, C. E., & Kennedy, R. T. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5755-7 · Cited by 44
3D microfabricated bioreactor with capillaries
Xia, C., & Fang, N. X. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9350-4 · Cited by 38
Yu, F. B., Horowitz, M., & Quake, S. R. (2013) · Lab on a Chip · doi:10.1039/c3lc41394b · Cited by 25
Cited by
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
3D printed microfluidics for biological applications
Ho, C. M. B., Ng, S. H., Li, K. H. H., & Yoon, Y.-J. (2015) · Lab on a Chip · doi:10.1039/c5lc00685f · Cited by 704
Novel Materials for 3D Printing by Photopolymerization
Layani, M., Wang, X., & Magdassi, S. (2018) · Advanced Materials · doi:10.1002/adma.201706344 · Cited by 561
Custom 3D printer and resin for 18 μm × 20 μm microfluidic flow channels
Gong, H., Bickham, B. P., Woolley, A. T., & Nordin, G. P. (2017) · Lab on a Chip · doi:10.1039/c7lc00644f · Cited by 443
Self-citation
Metadata
- Authors
- Rogers, C. I., Qaderi, K., Woolley, A. T., & Nordin, G. P.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-01-01
- Volume
- 9
- Issue
- 1
- Pages
- 016501-016501
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2081153064
- Cited by
- 297
- References
- 35
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.