Precise determination of micromotion for trapped-ion optical clocks
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low 10−18 range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below |Δν/ν|=1×10−20 can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of 10−19 is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of |Δν/ν|=1×10−20 as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum Computations with Cold Trapped Ions
Cirac, J. I., & Zoller, P. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.4091 · Cited by 3,733
Quantum dynamics of single trapped ions
Leibfried, D., Blatt, R., Monroe, C., & Wineland, D. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.281 · Cited by 2,739
Experimental issues in coherent quantum-state manipulation of trapped atomic ions
Wineland, D. J., Monroe, C., Itano, W. M., Leibfried, D., King, B. E., & Meekhof, D. M. (1998) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.103.019 · Cited by 1,497
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Effective Quantum Spin Systems with Trapped Ions
Porras, D., & Cirac, J. I. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.207901 · Cited by 872
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Simulating a quantum magnet with trapped ions
Friedenauer, A., Schmitz, H., Glueckert, J. T., Porras, D., & Schaetz, T. (2008) · Nature Physics · doi:10.1038/nphys1032 · Cited by 602
Nonclassical radiation of a single stored ion
Diedrich, F., & Walther, H. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.203 · Cited by 587
Cited by
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Highly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., Crespo López-Urrutia, J. R., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 311
Optical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Stray electric fields or asymmetries in the rf field can cause excess micromotion, which can be compensated to reduce Doppler-induced frequency shifts (Berkeland et al. 1998; Keller et al., 2015).”
Self-citationLiquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18
Huang, Y., Zhang, B., Zeng, M., Hao, Y., Ma, Z., Zhang, H., Guan, H., Chen, Z., Wang, M., & Gao, K. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034041 · Cited by 82
Ca+40 ion optical clock with micromotion-induced shifts below 1×10−18
Huang (2019) · Physical Review A · doi:10.1103/physreva.99.011401 · Cited by 51
Toward a Transportable Ca+ Optical Clock with a Systematic Uncertainty of 4.8 × 10 −18
Zeng, M., Huang, Y., Zhang, B., Hao, Y., Ma, Z., Hu, R., Zhang, H., Chen, Z., Wang, M., Guan, H., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064004 · Cited by 23
Metadata
- Authors
- Keller, J., Partner, H. L., Burgermeister, T., & Mehlstäubler, T. E.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2015-09-08
- Volume
- 118
- Issue
- 10
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1584843495
- Cited by
- 113
- References
- 8
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.