Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 275

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Optical clock comparison for Lorentz symmetry testing

Open access
Sanner, Christian, Huntemann, Nils, Lange, Richard, Tamm, Christian, Peik, Ekkehard, Safronova, Marianna S., Porsev, Sergey G.·2019·Nature

Abstract

Questioning basic assumptions about the structure of space and time has greatly enhanced our understanding of nature. State-of-the-art atomic clocks1–3 make it possible to precisely test fundamental symmetry properties of spacetime and search for physics beyond the standard model at low energies of just a few electronvolts4. Modern tests of Einstein’s theory of relativity try to measure so-far-undetected violations of Lorentz symmetry5; accurately comparing the frequencies of optical clocks is a promising route to further improving such tests6. Here we experimentally demonstrate agreement between two single-ion optical clocks at the 10−18 level, directly validating their uncertainty budgets, over a six-month comparison period. The ytterbium ions of the two clocks are confined in separate ion traps with quantization axes aligned along non-parallel directions. Hypothetical Lorentz symmetry violations5–7 would lead to periodic modulations of the frequency offset as the Earth rotates and orbits the Sun. From the absence of such modulations at the 10−19 level we deduce stringent limits of the order of 10−21 on Lorentz symmetry violation parameters for electrons, improving previous limits8–10 by two orders of magnitude. Such levels of precision will be essential for low-energy tests of future quantum gravity theories describing dynamics at the Planck scale4, which are expected to predict the magnitude of residual symmetry violations. Agreement between two single-ion clocks is demonstrated experimentally at the 10−18 level over a six-month period, confirming a key postulate of Einstein’s theory of relativity with hundredfold-improved precision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-019-0972-2

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 275

Metadata

Authors
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G.
Venue
Nature
Published
2019-03
Volume
567
Issue
7747
Pages
204-208
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2894213261
Cited by
275
References
39
FWCI
12.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical clock comparison for Lorentz symmetry testing. https://app.cochat.ai/papers/10.1038/s41586-019-0972-2
The paper
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019). Optical clock comparison for Lorentz symmetry testing. Nature. https://doi.org/10.1038/s41586-019-0972-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.