The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Real-time dual-comb spectroscopy with a free-running bidirectionally mode-locked fiber laser
Abstract
Dual-comb technique has enabled exciting applications in high resolution spectroscopy, precision distance measurements, and 3D imaging. Major advantages over traditional methods can be achieved with dual-comb technique. For example, dual-comb spectroscopy provides orders of magnitude improvement in acquisition speed over standard Fourier-transform spectroscopy while still preserving the high resolution capability. Wider adoption of the technique has, however, been hindered by the need for complex and expensive ultrafast laser systems. Here, we present a simple and robust dual-comb system that employs a free-running bidirectionally mode-locked fiber laser operating at telecommunication wavelength. Two femtosecond frequency combs (with a small difference in repetition rates) are generated from a single laser cavity to ensure mutual coherent properties and common noise cancellation. As the result, we have achieved real-time absorption spectroscopy measurements without the need for complex servo locking with accurate frequency referencing, and relatively high signal-to-noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coherent Raman spectro-imaging with laser frequency combs
Ideguchi, T., Holzner, S., Bernhardt, B., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2013) · Nature · doi:10.1038/nature12607 · Cited by 475
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Adaptive real-time dual-comb spectroscopy
Ideguchi, T., Poisson, A., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2014) · Nature Communications · doi:10.1038/ncomms4375 · Cited by 434
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322
Direct-comb molecular spectroscopy with accurate, resolved comb teeth over 43 THz
Zolot, A. M., Giorgetta, F. R., Baumann, E., Nicholson, J. W., Swann, W. C., Coddington, I., & Newbury, N. R. (2012) · Optics Letters · doi:10.1364/ol.37.000638 · Cited by 145
Cited by
Picqué, N., & Hänsch, T. W. (2019) · Nature Photonics · doi:10.1038/s41566-018-0347-5 · Cited by 1,255
On-chip dual-comb source for spectroscopy
Dutt, A., Joshi, C., Ji, X., Cardenas, J., Okawachi, Y., Luke, K., Gaeta, A. L., & Lipson, M. (2018) · Science Advances · doi:10.1126/sciadv.1701858 · Cited by 453
Applications of optical microcombs
Sun, Y., Wu, J., Tan, M., Xu, X., Li, Y., Morandotti, R., Mitchell, A., & Moss, D. J. (2023) · Advances in Optics and Photonics · doi:10.1364/aop.470264 · Cited by 302
Self-corrected chip-based dual-comb spectrometer
Hébert, N. B., Genest, J., Deschênes, J.-D., Bergeron, H., Chen, G. Y., Khurmi, C., & Lancaster, D. G. (2017) · Optics Express · doi:10.1364/oe.25.008168 · Cited by 122
Dual terahertz comb spectroscopy with a single free-running fibre laser
Hu, G., Mizuguchi, T., Oe, R., Nitta, K., Zhao, X., Minamikawa, T., Li, T., Zheng, Z., & Yasui, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-29403-9 · Cited by 56
Metadata
- Authors
- Mehravar, S., Norwood, R. A., Peyghambarian, N., & Kieu, K.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2016-06-06
- Volume
- 108
- Issue
- 23
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2415101272
- Cited by
- 205
- References
- 5
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time dual-comb spectroscopy with a free-running bidirectionally mode-locked fiber laser. https://app.cochat.ai/papers/10.1063/1.4953400
- The paper
- Mehravar, S., Norwood, R. A., Peyghambarian, N., & Kieu, K. (2016). Real-time dual-comb spectroscopy with a free-running bidirectionally mode-locked fiber laser. Applied Physics Letters. https://doi.org/10.1063/1.4953400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.