Superconducting nanowire detector jitter limited by detector geometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Detection jitter quantifies variance introduced by the detector in the determination of photon arrival time. It is a crucial performance parameter for systems using superconducting nanowire single photon detectors (SNSPDs). In this work, we have demonstrated that the detection timing jitter is limited in part by the spatial variation of the photon detection events along the length of the wire. We define this jitter source as a geometric jitter since it is related to the length and area of the SNSPD. To characterize the geometric jitter, we have constructed a differential cryogenic readout with less than 7 ps of an electronic jitter that can amplify the pulses generated from the two ends of an SNSPD. By differencing the measured arrival times of the two electrical pulses, we were able to partially cancel out the difference of the propagation times and thus reduce the uncertainty of the photon arrival time. We proved that the variation of the differential propagation time was a few ps for a 3 μm × 3 μm device, while it increased up to 50 ps for a 20 μm × 20 μm device. In a 20 μm × 20 μm large SNSPD, we achieved a 20% reduction in the overall detection timing jitter for detecting the telecom-wavelength photons by using the differential cryogenic readout.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Cited by
Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector
Korzh, B., Zhao, Q.-Y., Allmaras, J. P., Frasca, S., Autry, T. M., Bersin, E. A., Beyer, A. D., Briggs, R. M., Bumble, B., Colangelo, M., et al. (2020) · Nature Photonics · doi:10.1038/s41566-020-0589-x · Cited by 564
Self-citationEsmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Superconducting nanowire single-photon detectors for quantum information
You, L. (2020) · Nanophotonics · doi:10.1515/nanoph-2020-0186 · Cited by 257
Waveguide-integrated superconducting nanowire single-photon detectors
Ferrari, S., Schuck, C., & Pernice, W. (2017) · Nanophotonics · doi:10.1515/nanoph-2018-0059 · Cited by 167
A scalable multi-photon coincidence detector based on superconducting nanowires
Zhu, D., Zhao, Q.-Y., Choi, H., Lu, T.-J., Dane, A. E., Englund, D., & Berggren, K. K. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0160-9 · Cited by 85
Self-citationCheng, R., Wang, S., Zou, C.-L., & Tang, H. X. (2020) · Photonics Research · doi:10.1364/prj.390945 · Cited by 5
Metadata
- Authors
- Calandri, N., Zhao, Q.-Y., Zhu, D., Dane, A., & Berggren, K. K.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2016-10-10
- Volume
- 109
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2497308166
- Cited by
- 116
- References
- 1
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.