CoChat

Superconducting nanowire detector jitter limited by detector geometry

Open access
Calandri, Niccolò, Zhao, Qing-Yuan, Zhu, Di, Dane, Andrew, Berggren, Karl K. · 2016 · Applied Physics Letters
Cited by 116

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Detection jitter quantifies variance introduced by the detector in the determination of photon arrival time. It is a crucial performance parameter for systems using superconducting nanowire single photon detectors (SNSPDs). In this work, we have demonstrated that the detection timing jitter is limited in part by the spatial variation of the photon detection events along the length of the wire. We define this jitter source as a geometric jitter since it is related to the length and area of the SNSPD. To characterize the geometric jitter, we have constructed a differential cryogenic readout with less than 7 ps of an electronic jitter that can amplify the pulses generated from the two ends of an SNSPD. By differencing the measured arrival times of the two electrical pulses, we were able to partially cancel out the difference of the propagation times and thus reduce the uncertainty of the photon arrival time. We proved that the variation of the differential propagation time was a few ps for a 3 μm × 3 μm device, while it increased up to 50 ps for a 20 μm × 20 μm device. In a 20 μm × 20 μm large SNSPD, we achieved a 20% reduction in the overall detection timing jitter for detecting the telecom-wavelength photons by using the differential cryogenic readout.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.4963158

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 116

Metadata

Authors
Calandri, N., Zhao, Q.-Y., Zhu, D., Dane, A., & Berggren, K. K.
Venue
Applied Physics Letters
Published
2016-10-10
Volume
109
Issue
15
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2497308166
Cited by
116
References
1
FWCI
8.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.