Here we describe a bench-top cryostat system to control the temperature of liquid ethane in a cryo-plunge apparatus designed for biological specimen preparation for electron cryomicroscopy. It comprises a foam insulated Dewar containing a copper cryostat cup, whose temperature is controlled via an active feedback system to within 0.1 K. The device can easily be incorporated into existing manual and semi-automatic cryo-plunge instruments that are not equipped with cryogenic temperature control. Over the course of normal use, we find that using a cryostat is convenient, fast, and does not require special mixtures of cryogens like ethane/propane. This simple cryostat improves the reliability and reproducibility of biological specimen preparation for electron cryomicroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Cryoelectron microscopy of liposomes
Frederik, P. M., & Hubert, D. H. W. (2005) · Methods in Enzymology · doi:10.1016/s0076-6879(05)91024-0 · Cited by 121
Cited by
Structure of a human 48 S translational initiation complex
Brito Querido, J., Sokabe, M., Kraatz, S., Gordiyenko, Y., Skehel, J. M., Fraser, C. S., & Ramakrishnan, V. (2020) · Science · doi:10.1126/science.aba4904 · Cited by 266
Structure of the SARS-CoV-2 RNA-dependent RNA polymerase in the presence of favipiravir-RTP
Naydenova, K., Muir, K. W., Wu, L.-F., Zhang, Z., Coscia, F., Peet, M. J., Castro-Hartmann, P., Qian, P., Sader, K., Dent, K., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2021946118 · Cited by 187
“The grids were immediately plunged into liquid ethane kept at 93 K in a cryostat (19), and were stored in liquid nitrogen until they were imaged in the electron cryomicroscope.”
MethodSelf-citationIn situ architecture of the ER–mitochondria encounter structure
Wozny, M. R., Di Luca, A., Morado, D. R., Picco, A., Khaddaj, R., Campomanes, P., Ivanović, L., Hoffmann, P. C., Miller, E. A., Vanni, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06050-3 · Cited by 134
(2024) · doi:10.1038/s41594-023-01196-0 · Cited by 92
Clamping of DNA shuts the condensin neck gate
Lee, B.-G., Rhodes, J., & Löwe, J. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2120006119 · Cited by 49
Metadata
- Authors
- Russo, C. J., Scotcher, S., & Kyte, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2016-11-01
- Volume
- 87
- Issue
- 11
- Pages
- 114302-114302
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2554811053
- Cited by
- 54
- References
- 2
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A precision cryostat design for manual and semi-automated cryo-plunge instruments. https://app.cochat.ai/papers/10.1063/1.4967864
- The paper
- Russo, C. J., Scotcher, S., & Kyte, M. (2016). A precision cryostat design for manual and semi-automated cryo-plunge instruments. Review of Scientific Instruments. https://doi.org/10.1063/1.4967864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.