Comprehensive biocompatibility of nontoxic and high-output flexible energy harvester using lead-free piezoceramic thin film
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Flexible piezoelectric energy harvesters have been regarded as an overarching candidate for achieving self-powered electronic systems for environmental sensors and biomedical devices using the self-sufficient electrical energy. In this research, we realize a flexible high-output and lead-free piezoelectric energy harvester by using the aerosol deposition method and the laser lift-off process. We also investigated the comprehensive biocompatibility of the lead-free piezoceramic device using ex-vivo ionic elusion and in vivo bioimplantation, as well as in vitro cell proliferation and histologic inspection. The fabricated LiNbO3-doped (K,Na)NbO3 (KNN) thin film-based flexible energy harvester exhibited an outstanding piezoresponse, and average output performance of an open-circuit voltage of ∼130 V and a short-circuit current of ∼1.3 μA under normal bending and release deformation, which is the best record among previously reported flexible lead-free piezoelectric energy harvesters. Although both the KNN and Pb(Zr,Ti)O3 (PZT) devices showed short-term biocompatibility in cellular and histological studies, excessive Pb toxic ions were eluted from the PZT in human serum and tap water. Moreover, the KNN-based flexible energy harvester was implanted into a porcine chest and generated up to ∼5 V and 700 nA from the heartbeat motion, comparable to the output of previously reported lead-based flexible energy harvesters. This work can compellingly serve to advance the development of piezoelectric energy harvesting for actual and practical biocompatible self-powered biomedical applications beyond restrictions of lead-based materials in long-term physiological and clinical aspects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of heavy metal ions from wastewaters: A review
Fu, F., & Wang, Q. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.11.011 · Cited by 8,703
Hazards of heavy metal contamination
Järup, L. (2003) · British Medical Bulletin · doi:10.1093/bmb/ldg032 · Cited by 6,508
Wani, A. L., Ara, A., & Usmani, J. A. (2015) · Interdisciplinary Toxicology · doi:10.1515/intox-2015-0009 · Cited by 1,964
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Highly‐Efficient, Flexible Piezoelectric PZT Thin Film Nanogenerator on Plastic Substrates
Park, K., Son, J. H., Hwang, G., Jeong, C. K., Ryu, J., Koo, M., Choi, I., Lee, S. H., Byun, M., Wang, Z. L., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305659 · Cited by 835
Self-citationDagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
Cited by
Safaei, M., Sodano, H. A., & Anton, S. R. (2019) · Smart Materials and Structures · doi:10.1088/1361-665x/ab36e4 · Cited by 874
“More recently, Jeong et al in 2017 [412] fabricated a flexible”
MethodZhou, H., Zhang, Y., Qiu, Y., Wu, H., Qin, W., Liao, Y., Yu, Q., & Cheng, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112569 · Cited by 370
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
Flexible Piezoelectric Acoustic Sensors and Machine Learning for Speech Processing
Jung, Y. H., Hong, S. K., Wang, H. S., Han, J. H., Pham, T. X., Park, H., Kim, J., Kang, S., Yoo, C. D., & Lee, K. J. (2020) · Advanced Materials · doi:10.1002/adma.201904020 · Cited by 338
Self-citationPiezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
Metadata
- Authors
- Jeong, C. K., Han, J. H., Palneedi, H., Park, H., Hwang, G.-T., Joung, B., Kim, S.-G., Shin, H. J., Kang, I.-S., Ryu, J., & Lee, K. J.
- Venue
- APL Materials
- Publisher
- AIP Publishing
- Published
- 2017-02-22
- Volume
- 5
- Issue
- 7
- ISSN
- 2166-532X (ISSN-L)
- OpenAlex
- W2590948541
- Cited by
- 151
- References
- 6
- FWCI
- 15.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.