Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 344

The DOI matches its Crossref record; 159 of the 159 references it cites were found in a registry or an index.

Ferroelectric or non-ferroelectric: Why so many materials exhibit “ferroelectricity” on the nanoscale

Open access
Vasudevan, Rama K., Balke, Nina, Maksymovych, Peter, Jesse, Stephen, Kalinin, Sergei V.·2017·Applied Physics Reviews

Abstract

Ferroelectric materials have remained one of the major focal points of condensed matter physics and materials science for over 50 years. In the last 20 years, the development of voltage-modulated scanning probe microscopy techniques, exemplified by Piezoresponse force microscopy (PFM) and associated time- and voltage spectroscopies, opened a pathway to explore these materials on a single-digit nanometer level. Consequently, domain structures and walls and polarization dynamics can now be imaged in real space. More generally, PFM has allowed studying electromechanical coupling in a broad variety of materials ranging from ionics to biological systems. It can also be anticipated that the recent Nobel prize [“The Nobel Prize in Chemistry 2016,” http://www.nobelprize.org/nobel_prizes/chemistry/laureates/2016/ (Nobel Media, 2016)] in molecular electromechanical machines will result in rapid growth in interest in PFM as a method to probe their behavior on single device and device assembly levels. However, the broad introduction of PFM also resulted in a growing number of reports on the nearly ubiquitous presence of ferroelectric-like phenomena including remnant polar states and electromechanical hysteresis loops in materials which are non-ferroelectric in the bulk or in cases where size effects are expected to suppress ferroelectricity. While in certain cases plausible physical mechanisms can be suggested, there is remarkable similarity in observed behaviors, irrespective of the materials system. In this review, we summarize the basic principles of PFM, briefly discuss the features of ferroelectric surfaces salient to PFM imaging and spectroscopy, and summarize existing reports on ferroelectric-like responses in non-classical ferroelectric materials. We further discuss possible mechanisms behind observed behaviors and possible experimental strategies for their identification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.4979015

Cites

159 of 159 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 159 references

Cited by

See all 344

Metadata

Authors
Vasudevan, R. K., Balke, N., Maksymovych, P., Jesse, S., & Kalinin, S. V.
Venue
Applied Physics Reviews
Published
2017-05-01
Volume
4
Issue
2
ISSN
1931-9401 (ISSN-L)
OpenAlex
W2588941729
Cited by
344
References
159
FWCI
15.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ferroelectric or non-ferroelectric: Why so many materials exhibit “ferroelectricity” on the nanoscale. https://app.cochat.ai/papers/10.1063/1.4979015
The paper
Vasudevan, R. K., Balke, N., Maksymovych, P., Jesse, S., & Kalinin, S. V. (2017). Ferroelectric or non-ferroelectric: Why so many materials exhibit “ferroelectricity” on the nanoscale. Applied Physics Reviews. https://doi.org/10.1063/1.4979015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.